41 research outputs found

    Room-temperature control and electrical readout of individual nitrogen-vacancy nuclear spins

    Full text link
    Nuclear spins in semiconductors are leading candidates for quantum technologies, including quantum computation, communication, and sensing. Nuclear spins in diamond are particularly attractive due to their extremely long coherence lifetime. With the nitrogen-vacancy (NV) centre, such nuclear qubits benefit from an auxiliary electronic qubit, which has enabled entanglement mediated by photonic links. The transport of quantum information by the electron itself, via controlled transfer to an adjacent centre or via the dipolar interaction, would enable even faster and smaller processors, but optical readout of arrays of such nodes presents daunting challenges due to the required sub-diffraction inter-site distances. Here, we demonstrate the electrical readout of a basic unit of such systems - a single 14N nuclear spin coupled to the NV electron. Our results provide the key ingredients for quantum gate operations and electrical readout of nuclear qubit registers, in a manner compatible with nanoscale electrode structures. This demonstration is therefore a milestone towards large-scale diamond quantum devices with semiconductor scalability.Comment: 11 pages, 4 figure

    Comparison of Two Core Biopsy Techniques Before and After Laparoscopic Cryoablation of Small Renal Cortical Neoplasms

    Get PDF
    A pre-ablation standard biopsy technique resulted in the most accurate pathologic diagnosis for patients undergoing cryoablation for renal cortical neoplasms

    Functional and Psychosocial Outcomes of Hand Transplantation Compared with Prosthetic Fitting in Below-Elbow Amputees:A Multicenter Cohort Study

    Get PDF
    BACKGROUND:Hand-transplantation and improvements in the field of prostheses opened new frontiers in restoring hand function in below-elbow amputees. Both concepts aim at restoring reliable hand function, however, the indications, advantages and limitations for each treatment must be carefully considered depending on level and extent of amputation. Here we report our findings of a multi-center cohort study comparing hand function and quality-of-life of people with transplanted versus prosthetic hands. METHODS:Hand function in amputees with either transplant or prostheses was tested with Action Research Arm Test (ARAT), Southampton Hand Assessment Procedure (SHAP) and the Disabilities of the Arm, Shoulder and Hand measure (DASH). Quality-of-life was compared with the Short-Form 36 (SF-36). RESULTS:Transplanted patients (n = 5) achieved a mean ARAT score of 40.86 ± 8.07 and an average SHAP score of 75.00 ± 11.06. Prosthetic patients (n = 7) achieved a mean ARAT score of 39.00 ± 3.61 and an average SHAP score of 75.43 ± 10.81. There was no significant difference between transplanted and prosthetic hands in ARAT, SHAP or DASH. While quality-of-life metrics were equivocal for four scales of the SF-36, transplanted patients reported significantly higher scores in "role-physical" (p = 0.006), "vitality" (p = 0.008), "role-emotional" (p = 0.035) and "mental-health" (p = 0.003). CONCLUSIONS:The indications for hand transplantation or prosthetic fitting in below-elbow amputees require careful consideration. As functional outcomes were not significantly different between groups, patient's best interests and the route of least harm should guide treatment. Due to the immunosuppressive side-effects, the indication for allotransplantation must still be restrictive, the best being bilateral amputees

    Saturated Fats Compared With Unsaturated Fats and Sources of Carbohydrates in Relation to Risk of Coronary Heart Disease A Prospective Cohort Study

    Get PDF
    AbstractBackgroundThe associations between dietary saturated fats and the risk of coronary heart disease (CHD) remain controversial, but few studies have compared saturated with unsaturated fats and sources of carbohydrates in relation to CHD risk.ObjectivesThis study sought to investigate associations of saturated fats compared with unsaturated fats and different sources of carbohydrates in relation to CHD risk.MethodsWe followed 84,628 women (Nurses’ Health Study, 1980 to 2010), and 42,908 men (Health Professionals Follow-up Study, 1986 to 2010) who were free of diabetes, cardiovascular disease, and cancer at baseline. Diet was assessed by a semiquantitative food frequency questionnaire every 4 years.ResultsDuring 24 to 30 years of follow-up, we documented 7,667 incident cases of CHD. Higher intakes of polyunsaturated fatty acids (PUFAs) and carbohydrates from whole grains were significantly associated with a lower risk of CHD comparing the highest with lowest quintile for PUFAs (hazard ratio [HR]: 0.80, 95% confidence interval [CI]: 0.73 to 0.88; p trend <0.0001) and for carbohydrates from whole grains (HR: 0.90, 95% CI: 0.83 to 0.98; p trend = 0.003). In contrast, carbohydrates from refined starches/added sugars were positively associated with a risk of CHD (HR: 1.10, 95% CI: 1.00 to 1.21; p trend = 0.04). Replacing 5% of energy intake from saturated fats with equivalent energy intake from PUFAs, monounsaturated fatty acids, or carbohydrates from whole grains was associated with a 25%, 15%, and 9% lower risk of CHD, respectively (PUFAs, HR: 0.75, 95% CI: 0.67 to 0.84; p < 0.0001; monounsaturated fatty acids, HR: 0.85, 95% CI: 0.74 to 0.97; p = 0.02; carbohydrates from whole grains, HR: 0.91, 95% CI: 0.85 to 0.98; p = 0.01). Replacing saturated fats with carbohydrates from refined starches/added sugars was not significantly associated with CHD risk (p > 0.10).ConclusionsOur findings indicate that unsaturated fats, especially PUFAs, and/or high-quality carbohydrates can be used to replace saturated fats to reduce CHD risk

    Pulsed Photoelectric Coherent Manipulation and Detection of N − V Center Spins in Diamond

    Get PDF
    Hybrid photoelectric detection of NV magnetic resonances (PDMR) is anticipated to lead to scalable quantum chip technology. To achieve this goal, it is crucial to prove that PDMR readout is compatible with the coherent spin control. Here we present PDMR MW pulse protocols that filter background currents related to ionization of NS0 defects and achieve a high contrast and S/N ratio. We demonstrate Rabi and Ramsey protocols on shallow nitrogen-implanted electronic grade diamond and the coherent readout of ~ 5 NV spins, as a first step towards the fabrication of scalable photoelectric quantum devices

    Neutrophils induce paracrine telomere dysfunction and senescence in ROS‐dependent manner

    Get PDF
    Cellular senescence is characterized by an irreversible cell cycle arrest as well as a pro-inflammatory phenotype, thought to contribute to aging and age-related diseases. Neutrophils have essential roles in inflammatory responses; however, in certain contexts their abundance is associated with a number of age-related diseases, including liver disease. The relationship between neutrophils and cellular senescence is not well understood. Here, we show that telomeres in non-immune cells are highly susceptible to oxidative damage caused by neighboring neutrophils. Neutrophils cause telomere dysfunction both in vitro and ex vivo in a ROS-dependent manner. In a mouse model of acute liver injury, depletion of neutrophils reduces telomere dysfunction and senescence. Finally, we show that senescent cells mediate the recruitment of neutrophils to the aged liver and propose that this may be a mechanism by which senescence spreads to surrounding cells. Our results suggest that interventions that counteract neutrophil-induced senescence may be beneficial during aging and age-related disease

    Percutaneous Cryoablation of Pulmonary Metastases from Colorectal Cancer

    Get PDF
    Objective: To evaluate the safety and efficacy of cryoablation for metastatic lung tumors from colorectal cancer. Methods: The procedures were performed on 24 patients (36–82 years of age, with a median age of 62; 17 male patients, 7 female patients) for 55 metastatic tumors in the lung, during 30 sessions. The procedural safety, local progression free interval, and overall survival were assessed by follow-up computed tomographic scanning performed every 3–4 months. Results: The major complications were pneumothorax, 19 sessions (63%), pleural effusion, 21 sessions (70%), transient and self-limiting hemoptysis, 13 sessions (43%) and tract seeding, 1 session (3%). The 1- and 3-year local progression free intervals were 90.8 % and 59%, respectively. The 3-years local progression free intervals of tumors #15 mm in diameter was 79.8 % and that of tumors.15 mm was 28.6 % (p = 0.001; log-rank test). The 1- and 3-year overall survival rates were 91% and 59.6%, respectively. Conclusion: The results indicated that percutaneous cryoablation is a feasible treatment option. The local progression fre

    Crossing borders to bind proteins—a new concept in protein recognition based on the conjugation of small organic molecules or short peptides to polypeptides from a designed set

    Get PDF
    A new concept for protein recognition and binding is highlighted. The conjugation of small organic molecules or short peptides to polypeptides from a designed set provides binder molecules that bind proteins with high affinities, and with selectivities that are equal to those of antibodies. The small organic molecules or peptides need to bind the protein targets but only with modest affinities and selectivities, because conjugation to the polypeptides results in molecules with dramatically improved binder performance. The polypeptides are selected from a set of only sixteen sequences designed to bind, in principle, any protein. The small number of polypeptides used to prepare high-affinity binders contrasts sharply with the huge libraries used in binder technologies based on selection or immunization. Also, unlike antibodies and engineered proteins, the polypeptides have unordered three-dimensional structures and adapt to the proteins to which they bind. Binder molecules for the C-reactive protein, human carbonic anhydrase II, acetylcholine esterase, thymidine kinase 1, phosphorylated proteins, the D-dimer, and a number of antibodies are used as examples to demonstrate that affinities are achieved that are higher than those of the small molecules or peptides by as much as four orders of magnitude. Evaluation by pull-down experiments and ELISA-based tests in human serum show selectivities to be equal to those of antibodies. Small organic molecules and peptides are readily available from pools of endogenous ligands, enzyme substrates, inhibitors or products, from screened small molecule libraries, from phage display, and from mRNA display. The technology is an alternative to established binder concepts for applications in drug development, diagnostics, medical imaging, and protein separation

    The Liver INSPECTR Trial: Towards improved understanding of liver function following radiotherapy

    Get PDF
    Liver stereotactic ablative body radiotherapy (SABR) is an emerging treatment option for primary liver cancer and liver metastases. Liver SABR can provide high rates of local control however tumour doses are limited by dose to surrounding organs at risk including liver and gastrointestinal structures. Dose limits to liver are based on anatomical liver, without understanding of underlying liver function. This report describes a prospective clinical trial which measures the spatial variance of liver function through Tc-99m Mebrofenin SPECT in the context of liver SABR
    corecore