278 research outputs found
The Waveform Digitiser of the Double Chooz Experiment: Performance and Quantisation Effects on PhotoMultiplier Tube Signals
We present the waveform digitiser used in the Double Chooz experiment. We
describe the hardware and the custom-built firmware specifically developed for
the experiment. The performance of the device is tested with regards to
digitising low light level signals from photomultiplier tubes and measuring
pulse charge. This highlights the role of quantisation effects and leads to
some general recommendations on the design and use of waveform digitisers.Comment: 14 pages, 8 figures, accepted for publication in JINS
Characterization of ion/electron beam induced deposition of electrical contacts at the sub-{\mu}m scale
We investigate the fabrication of electrical contacts using ion- and
electron-beam induced deposition of platinum at the sub-\mu m scale. Halos
associated with the metal surface decoration are characterized electrically in
the 0.05-2 \mu m range using transport measurements, conducting atomic force
microscopy and Kelvin probe microscopy. In contrast with IBID, EBID electrodes
exhibit weakly conductive halos at the sub-\mu m scale, and can thus be used to
achieve resist-free electrical contacts for transport measurements at the
sub-\mu m scale. Four-point transport measurements using \mu m-spaced EBID
contacts are provided in the case of a multiwalled carbon nanotube
The Pandora multi-algorithm approach to automated pattern recognition of cosmic-ray muon and neutrino events in the MicroBooNE detector
The development and operation of Liquid-Argon Time-Projection Chambers for
neutrino physics has created a need for new approaches to pattern recognition
in order to fully exploit the imaging capabilities offered by this technology.
Whereas the human brain can excel at identifying features in the recorded
events, it is a significant challenge to develop an automated, algorithmic
solution. The Pandora Software Development Kit provides functionality to aid
the design and implementation of pattern-recognition algorithms. It promotes
the use of a multi-algorithm approach to pattern recognition, in which
individual algorithms each address a specific task in a particular topology.
Many tens of algorithms then carefully build up a picture of the event and,
together, provide a robust automated pattern-recognition solution. This paper
describes details of the chain of over one hundred Pandora algorithms and tools
used to reconstruct cosmic-ray muon and neutrino events in the MicroBooNE
detector. Metrics that assess the current pattern-recognition performance are
presented for simulated MicroBooNE events, using a selection of final-state
event topologies.Comment: Preprint to be submitted to The European Physical Journal
Design and construction of the MicroBooNE Cosmic Ray Tagger system
The MicroBooNE detector utilizes a liquid argon time projection chamber
(LArTPC) with an 85 t active mass to study neutrino interactions along the
Booster Neutrino Beam (BNB) at Fermilab. With a deployment location near ground
level, the detector records many cosmic muon tracks in each beam-related
detector trigger that can be misidentified as signals of interest. To reduce
these cosmogenic backgrounds, we have designed and constructed a TPC-external
Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for
High Energy Physics (LHEP), Albert Einstein center for fundamental physics,
University of Bern. The system utilizes plastic scintillation modules to
provide precise time and position information for TPC-traversing particles.
Successful matching of TPC tracks and CRT data will allow us to reduce
cosmogenic background and better characterize the light collection system and
LArTPC data using cosmic muons. In this paper we describe the design and
installation of the MicroBooNE CRT system and provide an overview of a series
of tests done to verify the proper operation of the system and its components
during installation, commissioning, and physics data-taking
Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC
The low-noise operation of readout electronics in a liquid argon time
projection chamber (LArTPC) is critical to properly extract the distribution of
ionization charge deposited on the wire planes of the TPC, especially for the
induction planes. This paper describes the characteristics and mitigation of
the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase
LArTPC comprises two induction planes and one collection sense wire plane with
a total of 8256 wires. Current induced on each TPC wire is amplified and shaped
by custom low-power, low-noise ASICs immersed in the liquid argon. The
digitization of the signal waveform occurs outside the cryostat. Using data
from the first year of MicroBooNE operations, several excess noise sources in
the TPC were identified and mitigated. The residual equivalent noise charge
(ENC) after noise filtering varies with wire length and is found to be below
400 electrons for the longest wires (4.7 m). The response is consistent with
the cold electronics design expectations and is found to be stable with time
and uniform over the functioning channels. This noise level is significantly
lower than previous experiments utilizing warm front-end electronics.Comment: 36 pages, 20 figure
Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE
The single-phase liquid argon time projection chamber (LArTPC) provides a
large amount of detailed information in the form of fine-grained drifted
ionization charge from particle traces. To fully utilize this information, the
deposited charge must be accurately extracted from the raw digitized waveforms
via a robust signal processing chain. Enabled by the ultra-low noise levels
associated with cryogenic electronics in the MicroBooNE detector, the precise
extraction of ionization charge from the induction wire planes in a
single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event
display images, and quantitatively demonstrated via waveform-level and
track-level metrics. Improved performance of induction plane calorimetry is
demonstrated through the agreement of extracted ionization charge measurements
across different wire planes for various event topologies. In addition to the
comprehensive waveform-level comparison of data and simulation, a calibration
of the cryogenic electronics response is presented and solutions to various
MicroBooNE-specific TPC issues are discussed. This work presents an important
improvement in LArTPC signal processing, the foundation of reconstruction and
therefore physics analyses in MicroBooNE.Comment: 54 pages, 36 figures; the first part of this work can be found at
arXiv:1802.0870
Measurement of cosmic-ray reconstruction efficiencies in the MicroBooNE LArTPC using a small external cosmic-ray counter
The MicroBooNE detector is a liquid argon time projection chamber at Fermilab
designed to study short-baseline neutrino oscillations and neutrino-argon
interaction cross-section. Due to its location near the surface, a good
understanding of cosmic muons as a source of backgrounds is of fundamental
importance for the experiment. We present a method of using an external 0.5 m
(L) x 0.5 m (W) muon counter stack, installed above the main detector, to
determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are
acquired with this external muon counter stack placed in three different
positions, corresponding to cosmic rays intersecting different parts of the
detector. The data reconstruction efficiency of tracks in the detector is found
to be , in good agreement with the Monte Carlo reconstruction
efficiency . This analysis represents
a small-scale demonstration of the method that can be used with future data
coming from a recently installed cosmic-ray tagger system, which will be able
to tag of the cosmic rays passing through the MicroBooNE
detector.Comment: 19 pages, 12 figure
Recommended from our members
The Pandora multi-algorithm approach to automated pattern recognition of cosmic-ray muon and neutrino events in the MicroBooNE detector.
The development and operation of liquid-argon time-projection chambers for neutrino physics has created a need for new approaches to pattern recognition in order to fully exploit the imaging capabilities offered by this technology. Whereas the human brain can excel at identifying features in the recorded events, it is a significant challenge to develop an automated, algorithmic solution. The Pandora Software Development Kit provides functionality to aid the design and implementation of pattern-recognition algorithms. It promotes the use of a multi-algorithm approach to pattern recognition, in which individual algorithms each address a specific task in a particular topology. Many tens of algorithms then carefully build up a picture of the event and, together, provide a robust automated pattern-recognition solution. This paper describes details of the chain of over one hundred Pandora algorithms and tools used to reconstruct cosmic-ray muon and neutrino events in the MicroBooNE detector. Metrics that assess the current pattern-recognition performance are presented for simulated MicroBooNE events, using a selection of final-state event topologies
A Deep Neural Network for Pixel-Level Electromagnetic Particle Identification in the MicroBooNE Liquid Argon Time Projection Chamber
We have developed a convolutional neural network (CNN) that can make a
pixel-level prediction of objects in image data recorded by a liquid argon time
projection chamber (LArTPC) for the first time. We describe the network design,
training techniques, and software tools developed to train this network. The
goal of this work is to develop a complete deep neural network based data
reconstruction chain for the MicroBooNE detector. We show the first
demonstration of a network's validity on real LArTPC data using MicroBooNE
collection plane images. The demonstration is performed for stopping muon and a
charged current neutral pion data samples
Recommended from our members
Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons
We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration
- …