935 research outputs found

    Launch vehicle trajectory optimization computer program, phase 4 Final technical report

    Get PDF
    Computer program for retrieving stored data and determining variations in launch vehicle performance as function of mission and vehicle parameter

    A method to measure the mirror reflectivity of a prime focus telescope

    Get PDF
    We have developed a method to measure the mirror reflectivity of telescopes. While it is relatively easy to measure the local reflectivity of the mirror material, it is not so straightforward to measure the amount of light that it focuses in a spot of a given diameter. Our method is based on the use of a CCD camera that is fixed on the mirror dish structure and observes simultaneously part of the telescope's focal plane and the sky region around its optical axis. A white diffuse reflecting disk of known reflectivity is fixed in the telescopes focal plane. During a typical reflectivity measurement the telescope is directed to a selected star. The CCD camera can see two images of the selected star, one directly and another one as a spot focused by the mirror on the white disk. The ratio of the reflected starlight integrated by the CCD from the white disk to the directly measured one provides a precise result of the product of (mirror area x mirror reflectivity)

    Launch vehicle trajectory optimization computer program, phase 4 Summary report

    Get PDF
    Computer program for launch vehicle trajectory optimizatio

    Tomographic imaging and scanning thermal microscopy: thermal impedance tomography

    Get PDF
    The application of tomographic imaging techniques developed for medical applications to the data provided by the scanning thermal microscope will give access to true three-dimensional information on the thermal properties of materials on a mm length scale. In principle, the technique involves calculating and inverting a sensitivity matrix for a uniform isotropic material, collecting ordered data at several modulation frequencies, and multiplying the inverse of the matrix with the data vector. In practice, inversion of the matrix in impractical, and a novel iterative technique is used. Examples from both simulated and real data are given

    Ecosystem services: An ecophysiological examination

    Full text link
    This review aims to discuss ecosystem services, provide illustrative case studies at catchment and local scales and present future research needs. This review discusses the following: (1) Ecosystem services (ES) are those goods and services that are provided by or are attributes of ecosystems that benefit humans. Examples of ES include the timber derived from a forest, the prevention of soil and coastal erosion by vegetation and the amelioration of dryland salinity through prevention of rises in the water table by trees. The provision of ES globally is in decline because of a lack of awareness of the total economic value of ES in the public, policy and political fora. (2) Providing a scientific understanding of the relationships among ecosystem structure, function and provision of ES, plus determining actual economic value of ES, are the central challenges to environmental scientists (including triple-bottom-line economists). (3) Some ES are widely dispersed throughout many different ecosystems. Carbon accumulation in trees and the contribution of biodiversity to ES provision are two examples of highly dispersed attributes common to many ecosystems. In contrast, other ES are best considered within the context of a single defined ecosystem (although they may occur in other ecosystems too). Mangroves as 'nursery' sites for juvenile fish is one example. (4) Examples of catchment-scale and local-scale provision of ES are discussed, along with future research issues for the nexus between ES and environmental sciences. © CSIRO 2005

    A patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange

    Get PDF
    Background: Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel – the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. Methods: In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. Results: Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. Conclusions: The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed

    Development of HPD Clusters for MAGIC-II

    Full text link
    MAGIC-II is the second imaging atmospheric Cherenkov telescope of the MAGIC observatory, which has recently been inaugurated on Canary island of La Palma. We are currently developing a new camera based on clusters of hybrid photon detectors (HPD) for the upgrade of MAGIC-II. The photon detectors feature a GaAsP photocathode and an avalanche diode as electron bombarded anodes with internal gain, and were supplied by Hamamatsu Photonics K.K. (R9792U-40). The HPD camera with high quantum efficiency will increase the MAGIC-II sensitivity and lower the energy threshold. The basic performance of the HPDs has been measured and a prototype of an HPD cluster has been developed to be mounted on MAGIC-II. Here we report on the status of the HPD cluster and the project of eventually using HPD clusters in the central area of the MAGIC-II camera.Comment: Contribution to the 31st ICRC, Lodz, Poland, July 200

    Guest Editorial Special Issue on Medical Imaging and Image Computing in Computational Physiology

    Get PDF
    International audienceThe January 2013 Special Issue of IEEE transactions on medical imaging discusses papers on medical imaging and image computing in computational physiology. Aslanid and co-researchers present an experimental technique based on stained micro computed tomography (CT) images to construct very detailed atrial models of the canine heart. The paper by Sebastian proposes a model of the cardiac conduction system (CCS) based on structural information derived from stained calf tissue. Ho, Mithraratne and Hunter present a numerical simulation of detailed cerebral venous flow. The third category of papers deals with computational methods for simulating medical imagery and incorporate knowledge of imaging physics and physiology/biophysics. The work by Morales showed how the combination of device modeling and virtual deployment, in addition to patient-specific image-based anatomical modeling, can help to carry out patient-specific treatment plans and assess alternative therapeutic strategies
    • …
    corecore