57 research outputs found
Liax Is a Surrogate Marker For Cell Envelope Stress and Daptomycin Non-Susceptibility in Enterococcus Faecium
Daptomycin (DAP) is often used as a first-line therapy to treat vancomycin-resistan
Recommended from our members
The XENONnT dark matter experiment.
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from multiply interacting massive particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This Letter places strong constraints on spin-independent interactions of dark matter particles with a mass between 1×10 and 2×10 GeV/c. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross sections for dark matter particles with masses close to the Planck scale
Detector signal characterization with a Bayesian network in XENONnT
We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform-based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment, which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of 5.9 ton. During the (1.09±0.03) ton yr exposure used for this search, the intrinsic Kr and Rn concentrations in the liquid target are reduced to unprecedentedly low levels, giving an electronic recoil background rate of (15.8±1.3) events/ton yr keV in the region of interest. A blind analysis of nuclear recoil events with energies between 3.3 and 60.5 keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of 2.58×10 cm for a WIMP mass of 28 GeV/c at 90% confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Multiple viable theoretical models predict heavy dark matter particles with a
mass close to the Planck mass, a range relatively unexplored by current
experimental measurements. We use 219.4 days of data collected with the XENON1T
experiment to conduct a blind search for signals from Multiply-Interacting
Massive Particles (MIMPs). Their unique track signature allows a targeted
analysis with only 0.05 expected background events from muons. Following
unblinding, we observe no signal candidate events. This work places strong
constraints on spin-independent interactions of dark matter particles with a
mass between 110GeV/c and 210GeV/c.
In addition, we present the first exclusion limits on spin-dependent
MIMP-neutron and MIMP-proton cross-sections for dark matter particles with
masses close to the Planck scale.Comment: 7 pages, 6 figure
The Triggerless Data Acquisition System of the XENONnT Experiment
The XENONnT detector uses the latest and largest liquid xenon-based timeprojection chamber (TPC) operated by the XENON Collaboration, aimed atdetecting Weakly Interacting Massive Particles and conducting other rare eventsearches. The XENONnT data acquisition (DAQ) system constitutes an upgraded andexpanded version of the XENON1T DAQ system. For its operation, it reliespredominantly on commercially available hardware accompanied by open-source andcustom-developed software. The three constituent subsystems of the XENONnTdetector, the TPC (main detector), muon veto, and the newly introduced neutronveto, are integrated into a single DAQ, and can be operated both independentlyand as a unified system. In total, the DAQ digitizes the signals of 698photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPCare digitized twice, at and gain. The DAQ for the mostpart is a triggerless system, reading out and storing every signal that exceedsthe digitization thresholds. Custom-developed software is used to process theacquired data, making it available within for live data quality monitoring and online analyses. The entire system withall the three subsystems was successfully commissioned and has been operatingcontinuously, comfortably withstanding readout rates that exceed MB/sduring calibration. Livetime during normal operation exceeds and is during most high-rate calibrations. The combined DAQ system hascollected more than 2 PB of both calibration and science data during thecommissioning of XENONnT and the first science run.<br
Search for events in XENON1T associated with Gravitational Waves
We perform a blind search for particle signals in the XENON1T dark matter
detector that occur close in time to gravitational wave signals in the LIGO and
Virgo observatories. No particle signal is observed in the nuclear recoil,
electronic recoil, CENS, and S2-only channels within 500 seconds of
observations of the gravitational wave signals GW170104, GW170729, GW170817,
GW170818, and GW170823. We use this null result to constrain mono-energetic
neutrinos and Beyond Standard Model particles emitted in the closest
coalescence GW170817, a binary neutron star merger. We set new upper limits on
the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at
90% confidence level. Furthermore, we constrain the product of coincident
fluence and cross section of Beyond Standard Model particles to be less than
cm/cm in the [5.5-210] keV energy range at 90% confidence
level
Design and performance of the field cage for the XENONnT experiment
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages
- …