61 research outputs found

    Probiotics improve symptoms of patients with COVID-19 through gut-lung axis: a systematic review and meta-analysis

    Get PDF
    BackgroundMulti system symptoms such as gastrointestinal tract and respiratory tract exist in coronavirus disease 2019 (COVID-19) patients. There is a lack of reliable evidence to prove that probiotics are effective in improving these symptoms. In this study, we aimed to evaluate the efficacy of probiotics in meta-analysis.MethodsWe systematically searched PubMed, Embase, Web of Science, and Cochrane Library up to February 15, 2023. Randomized controlled trials or high quality retrospective studies comparing the efficacy of probiotics as supplementation with non-probiotics in improving symptoms for patients with COVID-19 were included. This meta-analysis assessed endpoints using Review Manager 5.3.ResultTen citations comprising 1198 patients with COVID-19 were included. The results showed that probiotics could increase the number of people with overall symptom improvement (RR = 1.62, 95% CI [1.10, 2.38], P = 0.01) and shorten the duration (days) of overall symptoms (MD = −1.26, 95% CI [−2.36, −0.16], P = 0.02). For the duration (days) of specific symptoms, probiotics could improve diarrhea (MD = −2.12, 95% CI [−2.41, −1.83], P < 0.00001), cough (MD = −2.21, 95% CI [-4.56, 0.13], P = 0.06) and shortness of breath (MD = −1.37, 95% CI [-2.22, −0.53], P = 0.001). Probiotics had no obvious effect on fever, headache and weakness. For inflammation, probiotics could effectively reduce C-reactive Protein (CRP) serum level (mg/L) (MD = −4.03, 95% CI [−5.12, −2.93], P < 0.00001). Regarding hospital stay (days), probiotics group was shorter than non-probiotics group (MD = −0.98, 95% CI [−1.95, −0.01], P = 0.05).ConclusionTo some extent probiotics could improve the overall symptoms, inflammatory reaction and shorten hospital stay of patients with COVID-19. Probiotics may improve gastrointestinal symptoms (such as improving intestinal flora and reducing the duration of diarrhea) and further improve respiratory symptoms through the gut-lung axis.Systematic review registrationhttps://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=398309, identifier: CRD42023398309

    A new approach for quantifying epithelial and stromal thickness changes after orthokeratology contact lens wear

    Get PDF
    The aim of the study was to develop an automatic segmentation approach to optical coherence tomography (OCT) images and to investigate the changes in epithelial and stromal thickness profile and radius of curvature after the use of orthokeratology (Ortho-K) contact lenses. A total of 45 right eyes from 52 participants were monitored before, and after one month of, uninterrupted overnight Ortho-K lens wear. The tomography of their right eyes was obtained using optical OCT and rotating Scheimpflug imaging (OCULUS Pentacam). A custom-built MATLAB code for automatic segmentation of corneal OCT images was created and used to assess changes in epithelial thickness, stromal thickness, corneal and stromal profiles and radii of curvature before, and after one month of, uninterrupted overnight wear of Ortho-K lenses. In the central area (0–2 mm diameter), the epithelium thinned by 12.8 ± 6.0 µm (23.8% on average, p < 0.01) after one month of Ortho-K lens wear. In the paracentral area (2–5 mm diameter), the epithelium thinned nasally and temporally (by 2.4 ± 5.9 µm, 4.5% on average, p = 0.031). The stroma thickness increased in the central area (by 4.8 ± 16.1 µm, p = 0.005). The radius of curvature of the central corneal anterior surface increased by 0.24 ± 0.26 mm (3.1%, p < 0.01) along the horizontal meridian and by 0.34 ± 0.18 mm (4.2%, p < 0.01) along the vertical meridian. There were no significant changes in the anterior and posterior stromal radius of curvature. This study introduced a new method to automatically detect the anterior corneal surface, the epithelial posterior surface and the posterior corneal surface in OCT scans. Overnight wear of Ortho-K lenses caused thinning of the central corneal epithelium. The anterior corneal surface became flattered while the anterior and posterior surfaces of the stroma did not undergo significant changes. The results are consistent with the changes reported in previous studies. The reduction in myopic refractive error caused by Ortho-K lens wear was mainly due to changes in corneal epithelium thickness profile

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Prevalence, associated factors and outcomes of pressure injuries in adult intensive care unit patients: the DecubICUs study

    Get PDF
    Funder: European Society of Intensive Care Medicine; doi: http://dx.doi.org/10.13039/501100013347Funder: Flemish Society for Critical Care NursesAbstract: Purpose: Intensive care unit (ICU) patients are particularly susceptible to developing pressure injuries. Epidemiologic data is however unavailable. We aimed to provide an international picture of the extent of pressure injuries and factors associated with ICU-acquired pressure injuries in adult ICU patients. Methods: International 1-day point-prevalence study; follow-up for outcome assessment until hospital discharge (maximum 12 weeks). Factors associated with ICU-acquired pressure injury and hospital mortality were assessed by generalised linear mixed-effects regression analysis. Results: Data from 13,254 patients in 1117 ICUs (90 countries) revealed 6747 pressure injuries; 3997 (59.2%) were ICU-acquired. Overall prevalence was 26.6% (95% confidence interval [CI] 25.9–27.3). ICU-acquired prevalence was 16.2% (95% CI 15.6–16.8). Sacrum (37%) and heels (19.5%) were most affected. Factors independently associated with ICU-acquired pressure injuries were older age, male sex, being underweight, emergency surgery, higher Simplified Acute Physiology Score II, Braden score 3 days, comorbidities (chronic obstructive pulmonary disease, immunodeficiency), organ support (renal replacement, mechanical ventilation on ICU admission), and being in a low or lower-middle income-economy. Gradually increasing associations with mortality were identified for increasing severity of pressure injury: stage I (odds ratio [OR] 1.5; 95% CI 1.2–1.8), stage II (OR 1.6; 95% CI 1.4–1.9), and stage III or worse (OR 2.8; 95% CI 2.3–3.3). Conclusion: Pressure injuries are common in adult ICU patients. ICU-acquired pressure injuries are associated with mainly intrinsic factors and mortality. Optimal care standards, increased awareness, appropriate resource allocation, and further research into optimal prevention are pivotal to tackle this important patient safety threat

    A New Conformable Fractional-Order Time-Delay Grey Bernoulli Model with the Arithmetic Optimization Algorithm and Its Application in Rural Regional Economy

    No full text
    To further promote the development of the grey system theory, this paper develops a novel conformable fractional-order grey Bernoulli model with a time-delay effect, namely, the CFTDNGBM (1, 1) model. In addition, the arithmetic optimization algorithm (AOA) is incorporated into the system of the model to solve the hyperparameters existing in the model. Compared with the previous grey prediction models, the CFTDNGBM (1, 1) model with a conformable fractional-order accumulation operation (CFAO), time-delay factor, and Bernoulli parameter has stronger compatibility in structure. The proposed model and its nine competitive models with excellent performance are used to predict and analyze the consumption level and per capita consumption expenditure of rural residents in China to verify the feasibility of the proposed method. The case results show that in both cases, the seven descriptive indicators of the CFTDNGBM (1, 1) model are higher than those of its competing models. Therefore, the CFTDNGBM (1, 1) model has a certain application value
    corecore