230 research outputs found

    The Transmembrane Domain C of AMPA Receptors is Critically Involved in Receptor Function and Modulation

    Get PDF
    Ionotropic glutamate receptors are major players in synaptic transmission and are critically involved in many cognitive events. Although receptors of different subfamilies serve different functions, they all show a conserved domain topology. For most of these domains, structure–function relationships have been established and are well understood. However, up to date the role of the transmembrane domain C in receptor function has been investigated only poorly. We have constructed a series of receptor chimeras and point mutants designed to shed light on the structural and/or functional importance of this domain. We here present evidence that the role of transmembrane domain C exceeds that of a mere scaffolding domain and that several amino acid residues located within the domain are crucial for receptor gating and desensitization. Furthermore, our data suggest that the domain may be involved in receptor interaction with transmembrane AMPA receptor regulatory proteins

    Femtosecond laser-induced surface modification of the electrolyte in solid oxide electrolysis cells

    Get PDF
    Electrolyte-supported solid oxide cells are often used for steam electrolysis. Advantages are high mechanical stability and a low degradation rate. The aim of this proof of concept study was to use a femtosecond laser to process the electrolyte of an electrolyte-supported solid oxide cell and evaluate the effect of this laser treatment on the electrochemical performance. The femtosecond laser treatment induces a macroscopic and a superimposed microscopic structure. It can be proven that the electrolyte remains gas tight and the electrochemical performance increases independently of the laser parameters. The initial area-specific resistance degradation during a constant current measurement of 200 h was reduced from 7.9% for a non-treated reference cell to 3.2% for one of the laser-treated cells. Based on electrochemical impedance measurements, it was found that the high frequency resistance of the laser-treated cells was reduced by up to 20% with respect to the reference cell. The impedance spectra were evaluated by calculating the distribution of relaxation times, and in advance, a novel approach was used to approximate the gas concentration resistance, which was related to the test setup and not to the cell. It was found that the low frequency polarization resistance was increased for the laser-treated cells. In total, the area-specific resistance of the laser-treated cells was reduced by up to 14%

    Enzymatic Bromocyclization of alpha- and gamma-Allenols by Chloroperoxidase from Curvularia inaequalis

    Get PDF
    Vanadate-dependent chloroperoxidase from Curvularia inaequalis catalyzes 5-endo-trig bromocyclizations of alpha-allenols to produce valuable halofunctionalized furans as versatile synthetic building blocks. In contrast to other haloperoxidases, also the more challenging 5-exo-trig halocyclizations of gamma-allenols succeed with this system even though the scope still remains more narrow. Benefitting from the vanadate chloroperoxidase's high resiliency towards oxidative conditions, cyclization-inducing reactive hypohalite species are generated in situ from bromide salts and hydrogen peroxide. Crucial requirements for high conversions are aqueous biphasic emulsions as reaction media, stabilized by either cationic or non-ionic surfactants.Peer reviewe

    System Simulation and Analysis of an LNG-Fueled SOFC System Using Additively Manufactured High Temperature Heat Exchangers

    Get PDF
    A laboratory-scale solid oxide fuel cell (SOFC) system using liquefied natural gas (LNG) as a fuel is designed to be used as an energy converter on seagoing vessels (MultiSchIBZ project). The presented system design phase is supported by thermodynamic system simulation. As heat integration plays a crucial role with regard to fuel recirculation and endothermic pre-reforming, the heat exchanger and pre-reforming component models need to exhibit a high degree of accuracy throughout the entire operating range. Compact additively manufactured tube-bundle and plate-fin heat exchangers are designed to achieve high heat exchange efficiencies at low pressure losses. Their heat transfer correlations are derived from experimental component tests under operating conditions. A simulation study utilizing these heat exchanger characteristics is carried out for four configuration variants of pre-reforming and heat integration. Their system behaviour is analyzed with regard to the degree of pre-reforming and the outlet temperature of the fuel processing module. The combination of allothermal pre-reforming with additively manufactured plate-fin heat exchangers exhibits the best heat integration performance at nominal full load and yields a partial load capability to up to 60% electrical load at net electrical efficiencies of 58 to 60% (LHV). © 2022 by the authors. Licensee MDPI, Basel, Switzerland

    Nebulized heparin in burn patients with inhalation trauma : safety and feasibility

    Get PDF
    Background: Pulmonary hypercoagulopathy is intrinsic to inhalation trauma. Nebulized heparin could theoretically be beneficial in patients with inhalation injury, but current data are conflicting. We aimed to investigate the safety, feasibility, and effectiveness of nebulized heparin. Methods: International multicenter, double-blind, placebo-controlled randomized clinical trial in specialized burn care centers. Adult patients with inhalation trauma received nebulizations of unfractionated heparin (25,000 international unit (IU), 5 mL) or placebo (0.9% NaCl, 5 mL) every four hours for 14 days or until extubation. The primary outcome was the number of ventilator-free days at day 28 post-admission. Here, we report on the secondary outcomes related to safety and feasibility. Results: The study was prematurely stopped after inclusion of 13 patients (heparin N = 7, placebo N = 6) due to low recruitment and high costs associated with the trial medication. Therefore, no analyses on effectiveness were performed. In the heparin group, serious respiratory problems occurred due to saturation of the expiratory filter following nebulizations. In total, 129 out of 427 scheduled nebulizations were withheld in the heparin group (in 3 patients) and 45 out of 299 scheduled nebulizations were withheld in the placebo group (in 2 patients). Blood-stained sputum or expected increased bleeding risks were the most frequent reasons to withhold nebulizations. Conclusion: In this prematurely stopped trial, we encountered important safety and feasibility issues related to frequent heparin nebulizations in burn patients with inhalation trauma. This should be taken into account when heparin nebulizations are considered in these patients

    Optical control of NMDA-receptors with a diffusible photoswitch

    Get PDF
    N-methyl-D-aspartate receptors (NMDARs) play a central role in synaptic plasticity, learning and memory, and are implicated in various neuronal disorders. We synthesized a diffusible photochromic glutamate analogue, azobenzene-triazole-glutamate (ATG), which is specific for NMDARs and functions as a photoswitchable agonist. ATG is inactive in its dark-adapted trans-isoform, but can be converted into its active cis-isoform using one-photon (near UV) or two-photon (740 nm) excitation. Irradiation with violet light photo-inactivates ATG within milliseconds, allowing agonist removal on the timescale of NMDAR deactivation. ATG is compatible with Ca2+ imaging and can be used to optically mimic synaptic coincidence detection protocols. Thus, ATG can be used like traditional caged glutamate compounds, but with the added advantages of NMDAR specificity, low antagonism of GABAR-mediated currents, and precise temporal control of agonist delivery

    Metrology part 1:definition of quality criteria

    Get PDF
    Any measurement is always afflicted with some degree of uncertainty. A correct understanding of the different types of uncertainty, their naming, and their definition is of crucial importance for an appropriate use of measuring instruments. However, in perioperative and intensive care medicine, the metrological requirements for measuring instruments are poorly defined and often used spuriously. The correct use of metrological terms is also of crucial importance in validation studies. The European Union published a new directive on medical devices, mentioning that in the case of devices with a measuring function, the notified body is involved in all aspects relating to the conformity of the device with the metrological requirements. It is therefore the task of the scientific societies to establish the standards in their area of expertise. Adopting the same understandings and definitions among clinicians and scientists is obviously the first step. In this metrologic review (part 1), we list and explain the most important terms defined by the International Bureau of Weights and Measures regarding quantities and units, properties of measurements, devices for measurement, properties of measuring devices, and measurement standards, with specific examples from perioperative and intensive care medicine

    Metrology part 2:Procedures for the validation of major measurement quality criteria and measuring instrument properties

    Get PDF
    A measurement is always afflicted with some degree of uncertainty. A correct understanding of the different types of uncertainty, their naming, and their definition is of crucial importance for an appropriate use of the measuring instruments. However, in perioperative and intensive care medicine, the metrological requirements for measuring instruments are poorly defined and often used spuriously. The correct use of metrological terms is also of crucial importance in validation studies. The European Union published a new directive on medical devices, mentioning that in the case of devices with a measuring function, the notified body is involved in all aspects relating to the conformity of the device with the metrological requirements. It is therefore the task of scientific societies to establish the standards in their area of expertise. After adopting the same understandings and definitions (part 1), the different procedures for the validation of major quality criteria of measuring devices must be consensually established. In this metrologic review (part 2), we review the terms and definitions of validation, some basic processes leading to the display of an indication from a physiologic signal, and procedures for the validation of measuring instrument properties, with specific focus on perioperative and intensive care medicine including appropriate examples

    Association between early cumulative fluid balance and successful liberation from invasive ventilation in COVID-19 ARDS patients - insights from the PRoVENT-COVID study:a national, multicenter, observational cohort analysis

    Get PDF
    BACKGROUND: Increasing evidence indicates the potential benefits of restricted fluid management in critically ill patients. Evidence lacks on the optimal fluid management strategy for invasively ventilated COVID-19 patients. We hypothesized that the cumulative fluid balance would affect the successful liberation of invasive ventilation in COVID-19 patients with acute respiratory distress syndrome (ARDS). METHODS: We analyzed data from the multicenter observational 'PRactice of VENTilation in COVID-19 patients' study. Patients with confirmed COVID-19 and ARDS who required invasive ventilation during the first 3 months of the international outbreak (March 1, 2020, to June 2020) across 22 hospitals in the Netherlands were included. The primary outcome was successful liberation of invasive ventilation, modeled as a function of day 3 cumulative fluid balance using Cox proportional hazards models, using the crude and the adjusted association. Sensitivity analyses without missing data and modeling ARDS severity were performed. RESULTS: Among 650 patients, three groups were identified. Patients in the higher, intermediate, and lower groups had a median cumulative fluid balance of 1.98 L (1.27-7.72 L), 0.78 L (0.26-1.27 L), and - 0.35 L (- 6.52-0.26 L), respectively. Higher day 3 cumulative fluid balance was significantly associated with a lower probability of successful ventilation liberation (adjusted hazard ratio 0.86, 95% CI 0.77-0.95, P = 0.0047). Sensitivity analyses showed similar results. CONCLUSIONS: In a cohort of invasively ventilated patients with COVID-19 and ARDS, a higher cumulative fluid balance was associated with a longer ventilation duration, indicating that restricted fluid management in these patients may be beneficial. Trial registration Clinicaltrials.gov ( NCT04346342 ); Date of registration: April 15, 2020
    • …
    corecore