651 research outputs found

    Space shuttle booster Data Management System (DMS) requirements analysis. Volume 2: Detail requirements

    Get PDF
    Space shuttle subsystem interface description, subsystem computational requirements, and analysis program - Vol.

    A 10B-based neutron detector with stacked Multiwire Proportional Counters and macrostructured cathodes

    Full text link
    We present the results of the measurements of the detection efficiency for a 4.7 \r{A} neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes were made of Aluminum and had a surface exhibiting millimeter-deep V-shaped grooves of 45{\deg}, upon which the thin Boron film was deposited by DC magnetron sputtering. The incident neutrons interacting with the converter layer deposited on the sidewalls of the grooves have a higher capture probability, owing to the larger effective absorption film thickness. This leads to a higher overall detection efficiency for the grooved cathode when compared to a cathode with a flat surface. Both the experimental results and the predictions of the GEANT4 model suggests that a 5-counter detector stack with coated grooved cathodes has the same efficiency as a 7-counter stack with flat cathodes. The reduction in the number of counters in the stack without altering the detection efficiency will prove highly beneficial for large-area position-sensitive detectors for neutron scattering applications, for which the cost-effective manufacturing of the detector and associated readout electronics is an important objective. The proposed detector concept could be a technological option for one of the new chopper spectrometers and other instruments planned to be built at the future European Spallation Source in Sweden. These results with macrostructured cathodes generally apply not just to MWPCs but to other gaseous detectors as well.Comment: 14 pages, 9 figure

    Commentary: Global, regional, and national burden of neurological disorders during 1990–2015: a systematic analysis for the Global Burden of Disease Study 2015

    Get PDF
    A commentary on: Global, regional, and national burden of neurological disorders during 1990–2015: a systematic analysis for the Global Burden of Disease Study 2015 by GBD 2015 Neurological Disorders Collaborator Group. Lancet Neurol (2017) 16:877–97. doi: 10.1016/S1474-4422(17)30299-

    Neurochemical Aftermath of Repetitive Mild Traumatic Brain Injury

    Get PDF
    IMPORTANCE: Evidence is accumulating that repeated mild traumatic brain injury (mTBI) incidents can lead to persistent, long-term debilitating symptoms and in some cases a progressive neurodegenerative condition referred to as chronic traumatic encephalopathy. However, to our knowledge, there are no objective tools to examine to which degree persistent symptoms after mTBI are caused by neuronal injury. OBJECTIVE: To determine whether persistent symptoms after mTBI are associated with brain injury as evaluated by cerebrospinal fluid biochemical markers for axonal damage and other aspects of central nervous system injury. DESIGN, SETTINGS, AND PARTICIPANTS: A multicenter cross-sectional study involving professional Swedish ice hockey players who have had repeated mTBI, had postconcussion symptoms for more than 3 months, and fulfilled the criteria for postconcussion syndrome (PCS) according to the Diagnostic and Statistical Manual of Mental Disorders (Fourth Edition) matched with neurologically healthy control individuals. The participants were enrolled between January 2014 and February 2016. The players were also assessed with Rivermead Post Concussion Symptoms Questionnaire and magnetic resonance imaging. MAIN OUTCOMES AND MEASURES: Neurofilament light protein, total tau, glial fibrillary acidic protein, amyloid β, phosphorylated tau, and neurogranin concentrations in cerebrospinal fluid. RESULTS: A total of 31 participants (16 men with PCS; median age, 31 years; range, 22-53 years; and 15 control individuals [11 men and 4 women]; median age, 25 years; range, 21-35 years) were assessed. Of 16 players with PCS, 9 had PCS symptoms for more than 1 year, while the remaining 7 returned to play within a year. Neurofilament light proteins were significantly increased in players with PCS for more than 1 year (median, 410 pg/mL; range, 230-1440 pg/mL) compared with players whose PCS resolved within 1 year (median, 210 pg/mL; range, 140-460 pg/mL) as well as control individuals (median 238 pg/mL, range 128-526 pg/mL; P = .04 and P = .02, respectively). Furthermore, neurofilament light protein concentrations correlated with Rivermead Post Concussion Symptoms Questionnaire scores and lifetime concussion events (ρ = 0.58, P = .02 and ρ = 0.52, P = .04, respectively). Overall, players with PCS had significantly lower cerebrospinal fluid amyloid-β levels compared with control individuals (median, 1094 pg/mL; range, 845-1305 pg/mL; P = .05). CONCLUSIONS AND RELEVANCE: Increased cerebrospinal fluid neurofilament light proteins and reduced amyloid β were observed in patients with PCS, suggestive of axonal white matter injury and amyloid deposition. Measurement of these biomarkers may be an objective tool to assess the degree of central nervous system injury in individuals with PCS and to distinguish individuals who are at risk of developing chronic traumatic encephalopathy

    Exponential distribution of long heart beat intervals during atrial fibrillation and their relevance for white noise behaviour in power spectrum

    Full text link
    The statistical properties of heart beat intervals of 130 long-term surface electrocardiogram recordings during atrial fibrillation (AF) are investigated. We find that the distribution of interbeat intervals exhibits a characteristic exponential tail, which is absent during sinus rhythm, as tested in a corresponding control study with 72 healthy persons. The rate of the exponential decay lies in the range 3-12 Hz and shows diurnal variations. It equals, up to statistical uncertainties, the level of the previously uncovered white noise part in the power spectrum, which is also characteristic for AF. The overall statistical features can be described by decomposing the intervals into two statistically independent times, where the first one is associated with a correlated process with 1/f noise characteristics, while the second one belongs to an uncorrelated process and is responsible for the exponential tail. It is suggested to use the rate of the exponential decay as a further parameter for a better classification of AF and for the medical diagnosis. The relevance of the findings with respect to a general understanding of AF is pointed out

    Interactions in vivo between the Vif protein of HIV-1 and the precursor (Pr55GAG) of the virion nucleocapsid proteins

    Get PDF
    The abnormality of viral core structure seen in vif-defective HIV-1 grown in PBMCs has suggested a role for Vif in viral morphogenesis. Using an in vivo mammalian two-hybrid assay, the interaction between Vif and the precursor (Pr55GAG) of the virion nucleocapsid proteins has been analysed. This revealed the amino-terminal (aa 1–22) and central (aa 70–100) regions of Vif to be essential for its interaction with Pr55GAG, but deletion of the carboxy-terminal (aa 158–192) region of the protein had only a minor effect on its interaction. Initial deletion studies carried out on Pr55GAG showed that a 35-amino-acid region of the protein bridging the MA(p17)–CA(p24) junction was essential for its ability to interact with Vif. Site-directed mutagenesis of a conserved tryptophan (Trp21) near the amino terminus of Vif showed it to be important for the interaction with Pr55GAG. By contrast, mutagenesis of the highly conserved YLAL residues forming part of the BC-box motif, shown to be important in Vif promoting degradation of APOBEC3G/3F, had little or no effect on the Vif–Pr55GAG interaction
    corecore