132 research outputs found
Electric field measurements in atmospheric-pressure plasma jets
Atmospheric pressure non-thermal plasmas are researched for many applications. They became popular with plasma medicine, where restrictions on the plasmas are rigorous - they have to be at room temperature and not transfer significant amount of charge to the target, while still providing a mixture of reactive species, charge, field, to be efficient in medical applications. The intended applications soon extended to the treatment of different types of targets, where it is either important to treat them at atmospheric pressure (e.g. water) or with a plasma at room temperature. Atomic layer deposition is a good example of a traditionally low pressure technology being extended into the atmospheric pressure, and so is plasma catalysis. Another family of applications is in food and agriculture, where plasmas present a promising technology applied to a wide range of surfaces, dielectrics of different permittivities, in atmospheric air but also in humid conditions.The discharges used in these developments very often belong to the family of non-thermal atmospheric pressure plasmas - these are transient discharges, highly non-uniform in both space and time, small-scale (sub-mm), low ionization level, low light output, and most importantly sensitive to their environment. For example, a He plasma jet working in a kHz bullet mode changes its properties when impinging on a target with respect to the case when it expands freely into the ambient atmosphere. This is an important aspect to be kept in mind when bringing non-thermal atmospheric pressure plasmas intoapplications. It is also the motivation for the research presented in this talk. This work focuses on the fundamental properties of non-thermal plasmas such as the electric field, charge density and electron temperature. The work was performed on a non-thermal atmospheric pressure He plasma jet working in a kHz-driven mode with one ionization wave produced per voltage period or pulse. These fundamental properties of the discharge were measured in a freely expanding jet as well as when impinging on targets of different types, from low-permittivity dielectrics such as glass, to water, to metal. The measurements were performed in the plasma plume, but also in a target when a high-permittivity dielectric (er = 56) was used.The results bring one of the first sets of data concerning the E field, electron density and electron temperature, which are relatable to each other through the fact that they were all obtained on the same discharge. The effect of the gas flow speed is significant in the freely expanding jet, showing that the increased flow extends not only the visible length of the plasma plume, but also its electric field profile. In addition, the electron density and temperature were shown to respectively fall and rise within the plasma plume with increasing the distance from the end of the glass capillary.The presence of the target influences the plasma plume in several different ways. For low-permittivity targets, such as plastic or glass, the presence of the target does not significantly influence the plasma properties in the plume, but it does initiate surface discharges belonging to the family of ionization waves. The electric field induced in the target material by those surface ionization waves were measured, both axially, in the direction through the material, and radially. When the permittivity of the target is increased, the surface ionization waves are replaced by one or several return strokes and a significantly altered electric field profile, along with increased electron density and temperature. In the extreme case of the metallic target, combined with much higher electron densities, the duration of the discharge on the metal surface is extended to a microsecond. The work shows not only that the presence of the target influences the plasma, but that the properties of the target determine the plasma parameters, also in the gas phase
Improved standardization of flow cytometry diagnostic screening of primary immunodeficiency by software-based automated gating
Background
Multiparameter flow cytometry (FC) is essential in the diagnostic work-up and classification of primary immunodeficiency (PIDs). The EuroFlow PID Orientation tube (PIDOT) allows identification of all main lymphocyte subpopulations in blood. To standardize data analysis, tools for Automated Gating and Identification (AG&I) of the informative cell populations, were developed by EuroFlow. Here, we evaluated the contribution of these innovative AG&I tools to the standardization of FC in the diagnostic work-up of PID, by comparing AG&I against expert-based (EuroFlow-standardized) Manual Gating (MG) strategy, and its impact on the reproducibility and clinical interpretation of results.
Methods
FC data files from 44 patients (13 CVID, 12 PID, 19 non-PID) and 26 healthy donor (HD) blood samples stained with PIDOT were analyzed in parallel by MG and AG&I, using Infinicyt (TM) software (Cytognos). For comparison, percentage differences in absolute cell counts/mu L were calculated for each lymphocyte subpopulation. Data files showing differences >20% were checked for their potential clinical relevance, based on age-matched percentile (p5-p95) reference ranges. In parallel, intra- and inter-observer reproducibility of MG vs AG&I were evaluated in a subset of 12 samples.
Results
The AG&I approach was able to identify the vast majority of lymphoid events (>99%), associated with a significantly higher intra- and inter-observer reproducibility compared to MG. For most HD (83%) and patient (68%) samples, a high degree of agreement (<20% numerical differences in absolute cell counts/mu L) was obtained between MG and the AG&I module. This translated into a minimal impact (<5% of observations) on the final clinical interpretation. In all except three samples, extended expert revision of the AG&I approach revealed no error. In the three remaining samples aberrant maturation and/or abnormal marker expression profiles were seen leading in all three cases to numerical alarms by AG&I.
Conclusion
Altogether, our results indicate that replacement of MG by the AG&I module would be associated with a greater reproducibility and robustness of results in the diagnostic work-up of patients suspected of PID. However, expert revision of the results of AG&I of PIDOT data still remains necessary in samples with numerical alterations and aberrant B- and T-cell maturation and/or marker expression profiles
Long non-coding RNAs as novel therapeutic targets in juvenile myelomonocytic leukemia
Juvenile myelomonocytic leukemia (JMML) treatment primarily relies on hematopoietic stem cell transplantation and results in long-term overall survival of 50-60%, demonstrating a need to develop novel treatments. Dysregulation of the non-coding RNA transcriptome has been demonstrated before in this rare and unique disorder of early childhood. In this study, we investigated the therapeutic potential of targeting overexpressed long non-coding RNAs (lncRNAs) in JMML. Total RNA sequencing of bone marrow and peripheral blood mononuclear cell preparations from 19 untreated JMML patients and three healthy children revealed 185 differentially expressed lncRNA genes (131 up- and 54 downregulated). LNA GapmeRs were designed for 10 overexpressed and validated lncRNAs. Molecular knockdown (>= 70% compared to mock control) after 24 h of incubation was observed with two or more independent GapmeRs in 6 of them. For three lncRNAs (lnc-THADA-4, lnc-ACOT9-1 and NRIR) knockdown resulted in a significant decrease of cell viability after 72 h of incubation in primary cultures of JMML mononuclear cells, respectively. Importantly, the extent of cellular damage correlated with the expression level of the lncRNA of interest. In conclusion, we demonstrated in primary JMML cell cultures that knockdown of overexpressed lncRNAs such as lnc-THADA-4, lnc-ACOT9-1 and NRIR may be a feasible therapeutic strategy
Independent effect of prior exacerbation frequency and disease severity on the risk of future exacerbations of COPD: a retrospective cohort study
Few studies have researched the independent effect of COPD severity on the risk of future exacerbations adjusted by previous exacerbation frequency. We aimed to analyse the independent effect of COPD severity on the risk of exacerbations in the following year, and whether this effect was stronger or not than the effect of a previous history of exacerbations. We conducted a retrospective population-based cohort study including 900 patients with confirmed COPD. Exacerbation frequency was observed for the previous year and for the following year. Patients were defined as ‘Frequent Exacerbator’ (FE) phenotype if they suffered ?2 exacerbations in a year, and were categorised according to the severity of COPD (GOLD Grades 1–4). Odds ratios (ORs) were estimated by logistic regression adjusting for age, gender, smoking status, severity of COPD and being FE in the previous year. The main predictor of being FE among all grades of COPD severity was a history of frequent exacerbations in the previous year: adjusted OR 4.97; 95% confidence interval (CI) (3.54–6.97). COPD severity was associated with a higher risk of being FE: Crude OR GOLD Grade 4 3.86; 95% CI (1.50–9.93). However, this association diminished after adjusting for being FE in the previous year: adjusted OR 2.08; 95% CI (0.75–5.82). Our results support that a history of frequent exacerbations in the previous year is the most important independent predictor of exacerbations in the following year, also among the most severe COPD patients. Severity of COPD would be associated with a higher risk of exacerbations, but this effect would be partly determined by the exacerbations suffered in the previous year
Improved standardization of flow cytometry diagnostic screening of primary immunodeficiency by software-based automated gating
BackgroundMultiparameter flow cytometry (FC) is essential in the diagnostic work-up and classification of primary immunodeficiency (PIDs). The EuroFlow PID Orientation tube (PIDOT) allows identification of all main lymphocyte subpopulations in blood. To standardize data analysis, tools for Automated Gating and Identification (AG&I) of the informative cell populations, were developed by EuroFlow. Here, we evaluated the contribution of these innovative AG&I tools to the standardization of FC in the diagnostic work-up of PID, by comparing AG&I against expert-based (EuroFlow-standardized) Manual Gating (MG) strategy, and its impact on the reproducibility and clinical interpretation of results.MethodsFC data files from 44 patients (13 CVID, 12 PID, 19 non-PID) and 26 healthy donor (HD) blood samples stained with PIDOT were analyzed in parallel by MG and AG&I, using Infinicyt (TM) software (Cytognos). For comparison, percentage differences in absolute cell counts/mu L were calculated for each lymphocyte subpopulation. Data files showing differences >20% were checked for their potential clinical relevance, based on age-matched percentile (p5-p95) reference ranges. In parallel, intra- and inter-observer reproducibility of MG vs AG&I were evaluated in a subset of 12 samples.ResultsThe AG&I approach was able to identify the vast majority of lymphoid events (>99%), associated with a significantly higher intra- and inter-observer reproducibility compared to MG. For most HD (83%) and patient (68%) samples, a high degree of agreement (<20% numerical differences in absolute cell counts/mu L) was obtained between MG and the AG&I module. This translated into a minimal impact (<5% of observations) on the final clinical interpretation. In all except three samples, extended expert revision of the AG&I approach revealed no error. In the three remaining samples aberrant maturation and/or abnormal marker expression profiles were seen leading in all three cases to numerical alarms by AG&I.ConclusionAltogether, our results indicate that replacement of MG by the AG&I module would be associated with a greater reproducibility and robustness of results in the diagnostic work-up of patients suspected of PID. However, expert revision of the results of AG&I of PIDOT data still remains necessary in samples with numerical alterations and aberrant B- and T-cell maturation and/or marker expression profiles.Stemcel biology/Regenerative medicine (incl. bloodtransfusion
In-depth blood immune profiling of Good syndrome patients
[Introduction]: Good syndrome (GS) is a rare adult-onset immunodeficiency first described in 1954. It is characterized by the coexistence of a thymoma and hypogammaglobulinemia, associated with an increased susceptibility to infections and autoimmunity. The classification and management of GS has been long hampered by the lack of data about the underlying immune alterations, a controversy existing on whether it is a unique diagnostic entity vs. a subtype of Common Variable Immune Deficiency (CVID).[Methods]: Here, we used high-sensitive flow cytometry to investigate the distribution of up to 70 different immune cell populations in blood of GS patients (n=9) compared to age-matched CVID patients (n=55) and healthy donors (n=61).[Results]: All 9 GS patients displayed reduced B-cell counts -down to undetectable levels (<0.1 cells/μL) in 8/9 cases-, together with decreased numbers of total CD4+ T-cells, NK-cells, neutrophils, and basophils vs. age-matched healthy donors. In contrast, they showed expanded TCRγδ+ T-cells (p ≤ 0.05). Except for a deeper B-cell defect, the pattern of immune cell alteration in blood was similar in GS and (age-matched) CVID patients. In depth analysis of CD4+ T-cells revealed significantly decreased blood counts of naïve, central memory (CM) and transitional memory (TM) TCD4+ cells and their functional compartments of T follicular helper (TFH), regulatory T cells (Tregs), T helper (Th)2, Th17, Th22, Th1/Th17 and Th1/Th2 cells. In addition, GS patients also showed decreased NK-cell, neutrophil, basophil, classical monocyte and of both CD1c+ and CD141+ myeloid dendritic cell counts in blood, in parallel to an expansion of total and terminal effector TCRγδ+ T-cells. Interestingly, those GS patients who developed hypogammaglobulinemia several years after the thymoma presented with an immunological and clinical phenotype which more closely resembled a combined immune humoral and cellular defect, with poorer response to immunoglobulin replacement therapy, as compared to those in whom the thymoma and hypogammaglobulinemia were simultaneously detected.[Discussion]: Our findings provide a more accurate definition of the immune cell defects of GS patients and contribute to a better discrimination among GS patients between those with a pure B-cell defect vs. those suffering from a combined immunodeficiency with important consequences on the diagnosis and management of the disease.AT-V is supported by a grant from the Junta de Castilla y León (Fondo Social Europeo, Orden EDU/601/2020, Valladolid, Spain). This study has been founded by the Instituto de Salud Carlos III (ISCIII) through the project “PI20/01712” and co-founded by the European Union.Peer reviewe
Immunophenotypic Analysis of Acute Megakaryoblastic Leukemia: A EuroFlow Study
Acute megakaryoblastic leukemia (AMKL) is a rare and heterogeneous subtype of acute myeloid leukemia (AML). We evaluated the immunophenotypic profile of 72 AMKL and 114 non-AMKL AML patients using the EuroFlow AML panel. Univariate and multivariate/multidimensional analyses were performed to identify most relevant markers contributing to the diagnosis of AMKL. AMKL patients were subdivided into transient abnormal myelopoiesis (TAM), myeloid leukemia associated with Down syndrome (ML-DS), AML—not otherwise specified with megakaryocytic differentiation (NOS-AMKL), and AMKL—other patients (AML patients with other WHO classification but with flowcytometric features of megakaryocytic differentiation). Flowcytometric analysis showed good discrimination between AMKL and non-AMKL patients based on differential expression of, in particular, CD42a.CD61, CD41, CD42b, HLADR, CD15 and CD13. Combining CD42a.CD61 (positive) and CD13 (negative) resulted in a sensitivity of 71% and a specificity of 99%. Within AMKL patients, TAM and ML-DS patients showed higher frequencies of immature CD34+/CD117+ leukemic cells as compared to NOS-AMKL and AMKL-Other patients. In addition, ML-DS patients showed a significantly higher expression of CD33, CD11b, CD38 and CD7 as compared to the other three subgroups, allowing for good distinction of these patients. Overall, our data show that the EuroFlow AML panel allows for straightforward diagnosis of AMKL and that ML-DS is associated with a unique immunophenotypic profile.The EuroFlow Consortium received support from the FP6-2004-LIFESCIHEALTH-5 program of the European Commission (grant LSHB-CT-2006-018708) as Specific Targeted Research Project (STREP). The EuroFlow Consortium is part of the European Scientific Foundation for HematoOncology (ESLHO), a Scientific Working Group (SWG) of the European Hematology Association (EHA). The work of C.E.P. and E.S.C. was partially supported by FAPERJ (Grant E26/200.840/2021- CNE; E26/210.379/2018 and E26/110.105/2014); CAPES-PROEX; and CNPq (Grant 306258/2019-6 and 303765/2018-6). M.N. and E.M. were supported by the Ministry of Health of the Czech Republic,
grant number NU20J-07-00028. S.M. was supported by Acción Estratégica en Salud (AES) (Grant PI21_01115) and the grant of CIBERONC of the Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación, Madrid, Spain and FONDOS FEDER (no. CB16/12/00400)
Flow cytometric minimal residual disease assessment in B-cell precursor acute lymphoblastic leukaemia patients treated with CD19-targeted therapies — a EuroFlow study
The standardized EuroFlow protocol, including CD19 as primary B-cell marker, enables highly sensitive and reliable minimal residual disease (MRD) assessment in B-cell precursor acute lymphoblastic leukaemia (BCP-ALL) patients treated with chemotherapy. We developed and validated an alternative gating strategy allowing reliable MRD analysis in BCP-ALL patients treated with CD19-targeting therapies. Concordant data were obtained in 92% of targeted therapy patients who remained CD19-positive, whereas this was 81% in patients that became (partially) CD19-negative. Nevertheless, in both groups median MRD values showed excellent correlation with the original MRD data, indicating that, despite higher interlaboratory variation, the overall MRD analysis was correct.The EuroFlow Consortium received support from the FP6-2004-LIFESCIHEALTH-5 programme of the European Commission (grant LSHB-CT-2006-018708) as Specific Targeted Research Project (STREP). The EuroFlow Consortium is part of the European Scientific Foundation for Hemato-Oncology (ESLHO), a Scientific Working Group (SWG) of the European Hematology Association (EHA). TS and LS were supported by a Scientific Grant from the Medical University of Silesia Nr. PCN-1-050/K/0/K
- …