7,487 research outputs found

    Tracking Vector Magnetograms with the Magnetic Induction Equation

    Full text link
    The differential affine velocity estimator (DAVE) developed in Schuck (2006) for estimating velocities from line-of-sight magnetograms is modified to directly incorporate horizontal magnetic fields to produce a differential affine velocity estimator for vector magnetograms (DAVE4VM). The DAVE4VM's performance is demonstrated on the synthetic data from the anelastic pseudospectral ANMHD simulations that were used in the recent comparison of velocity inversion techniques by Welsch (2007). The DAVE4VM predicts roughly 95% of the helicity rate and 75% of the power transmitted through the simulation slice. Inter-comparison between DAVE4VM and DAVE and further analysis of the DAVE method demonstrates that line-of-sight tracking methods capture the shearing motion of magnetic footpoints but are insensitive to flux emergence -- the velocities determined from line-of-sight methods are more consistent with horizontal plasma velocities than with flux transport velocities. These results suggest that previous studies that rely on velocities determined from line-of-sight methods such as the DAVE or local correlation tracking may substantially misrepresent the total helicity rates and power through the photosphere.Comment: 30 pages, 13 figure

    Compositional Diversity of Late Cenozoic Basalts in a Transect Across the Southern Washington Cascades: Implications for Subduction Zone Magmatism

    Get PDF
    Major volcanoes of the Southern Washington Cascades (SWC) include the large Quaternary stratovolcanoes of Mount St. Helens (MSH) and Mount Adams (MA) and the Indian Heaven (IH) and Simcoe Mountain (SIM) volcanic fields. There are significant differences among these volcanic centers in terms of their composition and evolutionary history. The stratovolcanoes consist largely of andesitic to dacitic lavas and pyroclastics with minor basalt flows. IH consists dominantly of basaltic with minor andesite lavas, all erupted from monogenetic rift and cinder cone vents. SIM has a poorly exposed andesite to rhyolite core but mainly consists of basaltic lavas erupted from numerous widely dispersed vents; it has the morphology of a shield volcano. Distribution of mafic lavas across the SWC is related to north‐northwest trending faults and fissure zones that indicate a significant component of east–west extension within the area. There is overlap in eruptive history for the areas studied, but it appears that peak activity was progressively older (MSH (Ka), IH (mostl

    Swimming against the tide: a study of a neighbourhood trying to rediscover its ‘reason for being’– the case of South Bank, Redcar and Cleveland.

    Get PDF
    Many of the programmes and initiatives to regenerate deprived neighbourhoods appear to have had limited lasting impact. It has been argued that one reason for this is that we still have little real understanding of the nature and scale of the problems some communities face (Bernt, 2009). This article attempts to add to our knowledge through close study of an area with multiple problems and a history of failed regeneration attempts. An in-depth case study, undertaken to explore the current situation and future prospects of South Bank, a small neighbourhood in the North East of England, highlights transferable knowledge which may be applied to other regeneration areas. The analysis considers the nature and consequences of industrial decline; entrenched deprivation; the stigmatization of communities; the value of community consultation and the potential impact of retail-led regeneration. We question whether negative stigma attached to places can be changed and we ask what the future may hold for deprived communities now that public sector funding has largely dried up, and we consider an alternative approach: the potential impacts of private sector retail-led regeneration in the absence of public sector funding

    Calibration of centre-of-mass energies at LEP 2 for a precise measurement of the W boson mass

    Full text link
    The determination of the centre-of-mass energies for all LEP 2 running is presented. Accurate knowledge of these energies is of primary importance to set the absolute energy scale for the measurement of the W boson mass. The beam energy between 80 and 104 GeV is derived from continuous measurements of the magnetic bending field by 16 NMR probes situated in a number of the LEP dipoles. The relationship between the fields measured by the probes and the beam energy is defined in the NMR model, which is calibrated against precise measurements of the average beam energy between 41 and 61 GeV made using the resonant depolarisation technique. The validity of the NMR model is verified by three independent methods: the flux-loop, which is sensitive to the bending field of all the dipoles of LEP; the spectrometer, which determines the energy through measurements of the deflection of the beam in a magnet of known integrated field; and an analysis of the variation of the synchrotron tune with the total RF voltage. To obtain the centre-of-mass energies, corrections are then applied to account for sources of bending field external to the dipoles, and variations in the local beam energy at each interaction point. The relative error on the centre-of-mass energy determination for the majority of LEP 2 running is 1.2 x 10^{-4}, which is sufficiently precise so as not to introduce a dominant uncertainty on the W mass measurement.Comment: 79 pages, 45 figures, submitted to EPJ

    Evaluation of the LEP Centre-of-Mass Energy Above the W-Pair Production Threshold

    Get PDF
    Knowledge of the centre-of-mass energy at LEP2 is of primary importance to set the absolute energy scale for the measurement of the W-boson mass. The beam energy above 80 GeV is derived from continuous measurements of the magnetic bending field by 16 NMR probes situated in a number of the LEP dipoles. The relationship between the fields measured by the probes and the beam energy is calibrated against precise measurements of the average beam energy between 41 and 55 GeV made using the resonant depolarisation technique. The linearity of the relationship is tested by comparing the fields measured by the probes with the total bending field measured by a flux loop. This test results in the largest contribution to the systematic uncertainty. Several further corrections are applied to derive the the centre-of-mass energies at each interaction point. In addition the centre-of-mass energy spread is evaluated. The beam energy has been determined with a precision of 25 MeV for the data taken in 1997, corresponding to a relative precision of 2.7x10^{-4}. This is small in comparison to the present uncertainty on the W mass measurement at LEP. However, the ultimate statistical precision on the W mass with the full LEP2 data sample should be around 25 MeV, and a smaller uncertainty on the beam energy is desirable. Prospects for improvements are outlined.Comment: 24 pages, 10 figures, Latex, epsfig; replaced by version accepted by European Physical Journal

    High Resolution Hybrid Pixel Sensors for the e+e- TESLA Linear Collider Vertex Tracker

    Get PDF
    In order to fully exploit the physics potential of a future high energy e+e- linear collider, a Vertex Tracker, providing high resolution track reconstruction, is required. Hybrid Silicon pixel sensors are an attractive option, for the sensor technology, due to their read-out speed and radiation hardness, favoured in the high rate environment of the TESLA e+e- linear collider design but have been so far limited by the achievable single point space resolution. In this paper, a conceptual design of the TESLA Vertex Tracker, based on a novel layout of hybrid pixel sensors with interleaved cells to improve their spatial resolution, is presented.Comment: 12 pages, 5 figures, to appear in the Proceedings of the Vertex99 Workshop, Texel (The Netherlands), June 199

    On Synergies Between Information Retrieval and Digital Libraries

    Get PDF
    In this paper we present the results of a longitudinal analysis of ACM SIGIR papers from 2003 to 2017. ACM SIGIR is the main venue where Information Retrieval (IR) research and innovative results are presented yearly; it is a highly competitive venue and only the best and most relevant works are accepted for publication. The analysis of ACM SIGIR papers gives us a unique opportunity to understand where the field is going and what are the most trending topics in information access and search. In particular, we conduct this analysis with a focus on Digital Library (DL) topics to understand what is the relation between these two fields that we know to be closely linked. We see that DL provide document collections and challenging tasks to be addressed by the IR community and in turn exploit the latest advancements in IR to improve the offered services. We also point to the role of public investments in the DL field as one of the core drivers of DL research which in turn may also have a positive effect on information accessing and searching in general

    Refractive change following pseudophakic vitrectomy: a retrospective review

    Get PDF
    Background To assess the occurrence and magnitude of refractive change in pseudophakic eyes undergoing 20 gauge pars plana vitrectomy without scleral buckling and to investigate possible aetiological factors. Methods Retrospective case note review of 87 pseudophakic eyes undergoing 20 gauge pars plana vitrectomy for a variety of vitreo-retinal conditions over a three-year period. Anterior chamber depth (ACD) was measured before and after vitrectomy surgery in 32 eyes. Forty-three pseudophakic fellow eyes were used as controls. Results Eighty-seven eyes (84 patients) were included in the study. Mean spherical equivalent refraction prior to vitrectomy was -0.20 dioptres, which changed to a mean of -0.65 dioptres postoperatively (standard deviation of refractive change 0.59, range-2.13 to 0.75 dioptres) (p < 0.001). Sixty-one of the 87(70%) eyes experienced a myopic shift and 45(52%) eyes had a myopic shift of -0.5 dioptres or more. Mean fellow eye refraction was -0.19 dioptres preoperatively and -0.17 dioptres postoperatively (p = 0.14)(n = 37) Mean ACD preoperatively was 3.29 mm and postoperatively 3.27 mm (p = 0.53) (n = 32) and there was no significant change in ACD with tamponade use. Regression analysis revealed no statistically significant association between changes in anterior chamber depth, as well as a wide variety of other pre-, intra and postoperative factors examined, and the refractive change observed. Conclusion Significant refractive changes occur in some pseudophakic patients undergoing 20 g pars plana vitrectomy. The mean change observed was a small myopic shift but the range was large. The aetiology of the refractive change is uncertain

    Recent Results on Energy Calibration at LEP

    Get PDF
    The determination of the centre-of-mass energy at the four experiments installed on the CERN Large Electron Positron (LEP) collider is one of the major ingredients in the Standard Model investigations being carried on in the context of the experimental programme. Several depolarising effects at beam energies beyond 60 GeV limit the application of the Resonant Depolarisation (RD) method, which provi des an energy uncertainty of about ±1 MeV at the Z0 resonance. Extrapolation techniques from magnetic field measurements are used to obtain beam energies in the W-pair region, aiming at a total energy error £15 MeV. Consistency checks over a large range of precisely calibrated energies are mandatory to contain systematic errors from extrapolation. Progress obtained in extending the polarisable ener gy range in the 1997 LEP Run and the preliminary extrapolation errors are reported
    • 

    corecore