15 research outputs found

    Improved dead-time correction for PET scanners: Application to small-animal PET

    Get PDF
    Pile-up and dead-time are two main causes of nonlinearity in the response of a PET scanner as a function of activity in the field of view (FOV). For a given scanner and acquisition system, pile-up effects depend on the material and size of the object being imaged and on the distribution of activity inside and outside the FOV, because these factors change the singles-to-coincidences ratio (SCR). Thus, it is difficult to devise an accurate correction that would be valid for any acquisition. In this work, we demonstrate a linear relationship between SCR and effective dead-time, which measures the effects of both dead-time (losses) and pile-up (gains and losses). This relationship allows us to propose a simple method to accurately estimate dead-time and pile-up corrections using only two calibration acquisitions with, respectively, a high and low SCR. The method has been tested with simulations and experimental data for two different scanner geometries: a scanner with large area detectors and no pile-up rejection, and a scanner composed of two full rings of smaller detectors. Our results show that the SCR correction method is accurate within 7%, even for high activities in the FOV, and avoids the bias of the standard single-parameter method. © 2013 Institute of Physics and Engineering in Medicine.This work was partially funded by AMIT project (CEN-20101014) from the CDTICENIT program, CIBERsam (CB07/09/0031), projects TEC2010-21619-C04-01 and TEC2011-28972-C02-01 from Spanish Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE Grant, PSE-300000-2009-5), PRECISION grant IPT-300000- 2010-3, CPAN (CSD-2007-00042@Ingenio2010), MEC (FPA2010-17142) and ARTEMIS program (S2009/DPI-1802) from Spanish Comunidad de Madrid and EU-ERDF program.Peer Reviewe

    Recovery and normalization of triple coincidences in PET

    Get PDF
    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements.Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners.Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%.Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.This work was funded by Consejería de Educación, Juventud y Deporte de la Comunidad de Madrid (Spain) through the Madrid-MIT M + Visión Consortium. The authors also acknowledge the company Sedecal S.A. (Madrid, Spain) and the M + Visión Faculty for their support during this work.Publicad

    Noninvasive multiparametric characterization of mammary tumors with transmission-reflection optoacoustic ultrasound

    Get PDF
    Development of imaging methods capable of furnishing tumor-specific morphological, functional, and molecular information is paramount for early diagnosis, staging, and treatment of breast cancer. Ultrasound (US) and optoacoustic (OA) imaging methods exhibit excellent traits for tumor imaging in terms of fast imaging speed, ease of use, excellent contrast, and lack of ionizing radiation. Here, we demonstrate simultaneous tomographic whole body imaging of optical absorption, US reflectivity, and speed of sound (SoS) in living mice. In vivo studies of 4T1 breast cancer xenografts models revealed synergistic and complementary value of the hybrid imaging approach for characterizing mammary tumors. While neovasculature surrounding the tumor areas were observed based on the vascular anatomy contrast provided by the OA data, the tumor boundaries could be discerned by segmenting hypoechoic structures in pulse-echo US images. Tumor delineation was further facilitated by enhancing the contrast and spatial resolution of the SoS maps with a full-wave inversion method. The malignant lesions could thus be distinguished from other hypoechoic regions based on the average SoS values. The reported findings corroborate the strong potential of the hybrid imaging approach for advancing cancer research in small animal models and fostering development of new clinical diagnostic approaches

    Quasi elastic cross sections for the 209Bi(e,e'p)208Pb reaction: Jefferson Lab experiment E06007

    No full text
    6 pags., 4 figs., 1 tab. -- Rutherford Centennial Conference on Nuclear Physics 8–12 August 2011, Manchester, UKQuasi elastic cross sections were measured for the first time for both negative and positive missing momenta for the 209Bi(e, e′p) 208P b reaction leading to the ground state and hole states of 208P b. Experimental cross sections obtained between -0.3 GeV/c to 0.3 GeV/c agree with theoretical calculations using RDWIA techniques both in shape and magnitude for the ground state. The data for the ground state production of 208P b are consistent with a theoretical model assuming a single proton(1.06 ± 0.10) in the 1h9/2 orbit in 209Bi.Peer reviewe

    Parallel transmission pulse design with explicit control for the specific absorption rate in the presence of radiofrequency errors

    No full text
    Purpose A new framework for the design of parallel transmit (pTx) pulses is presented introducing constraints for local and global specific absorption rate (SAR) in the presence of errors in the radiofrequency (RF) transmit chain. Methods The first step is the design of a pTx RF pulse with explicit constraints for global and local SAR. Then, the worst possible SAR associated with that pulse due to RF transmission errors (“worst-case SAR”) is calculated. Finally, this information is used to re-calculate the pulse with lower SAR constraints, iterating this procedure until its worst-case SAR is within safety limits. Results Analysis of an actual pTx RF transmit chain revealed amplitude errors as high as 8% (20%) and phase errors above 3° (15°) for spokes (spiral) pulses. Simulations show that using the proposed framework, pulses can be designed with controlled “worst-case SAR” in the presence of errors of this magnitude at minor cost of the excitation profile quality. Conclusion Our worst-case SAR-constrained pTx design strategy yields pulses with local and global SAR within the safety limits even in the presence of RF transmission errors. This strategy is a natural way to incorporate SAR safety factors in the design of pTx pulses.National Institutes of Health (U.S.) (R01EB006847

    Computer-Vision Techniques for Water-Fat Separation in Ultra High-Field MRI Local Specific Absorption Rate Estimation

    No full text
    Objective: The purpose of this paper is to prove that computer-vision techniques allow synthesizing water-fat separation maps for local specific absorption rate (SAR) estimation, when patient-specific water-fat images are not available. Methods: We obtained ground truth head models by using patient-specific water-fat images. We obtained two different label-fusion water-fat models generating a water-fat multiatlas and applying the STAPLE and local-MAP-STAPLE label-fusion methods. We also obtained patch-based water-fat models applying a local group-wise weighted combination of the multiatlas. Electromagnetic (EM) simulations were performed, and B1+ magnitude and 10 g averaged SAR maps were generated. Results: We found local approaches provide a high DICE overlap (72.6 ± 10.2% fat and 91.6 ± 1.5% water in local-MAP-STAPLE, and 68.8 ± 8.2% fat and 91.1 ± 1.0% water in patch-based), low Hausdorff distances (18.6 ± 7.7 mm fat and 7.4 ± 11.2 mm water in local-MAP-STAPLE, and 16.4 ± 8.5 mm fat and 7.2 ± 11.8 mm water in patch-based) and a low error in volume estimation (15.6 ± 34.4% fat and 5.6 ± 4.1% water in the local-MAP-STAPLE, and 14.0 ± 17.7% fat and 4.7 ± 2.8% water in patch-based). The positions of the peak 10 g-averaged local SAR hotspots were the same for every model. Conclusion: We have created patient-specific head models using three different computer-vision-based water-fat separation approaches and compared the predictions of B1+ field and SAR distributions generated by simulating these models. Our results prove that a computer-vision approach can be used for patient-specific water-fat separation, and utilized for local SAR estimation in high-field MRI. Significance: Computer-vision approaches can be used for patient-specific water-fat separation and for patient specific local SAR estimation, when water-fat images of the patient are not available

    Inter-rater variability in the evaluation of lung ultrasound in videos acquired from COVID-19 patients

    No full text
    Lung ultrasound (LUS) allows for the detection of a series of manifestations of COVID-19, such as B-lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the performance of the test in a longitudinal or transverse orientation. Thirty-three physicians with advanced experience in LUS independently evaluated ultrasound videos previously acquired using the ULTRACOV system on 20 patients with confirmed COVID-19. For each patient, 24 videos of 3 s were acquired (using 12 positions with the probe in longitudinal and transverse orientations). The physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS ( = 0.74), with only a fair IRR for the presence of individual B-lines ( = 0.36) and for confluent B-lines occupying 50% ( = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR for LUS of COVID-19 patients may benefit from more standardized clinical protocols

    Multimodal assessment of non-alcoholic fatty liver disease with transmission-reflection optoacoustic ultrasound

    No full text
    Non-alcoholic fatty liver disease (NAFLD) is an umbrella term referring to a group of conditions associated to fat deposition and damage of liver tissue. Early detection of fat accumulation is essential to avoid progression of NAFLD to serious pathological stages such as liver cirrhosis and hepatocellular carcinoma. Methods: We exploited the unique capabilities of transmission-reflection optoacoustic ultrasound (TROPUS), which combines the advantages of optical and acoustic contrasts, for an early-stage multi-parametric assessment of NAFLD in mice. Results: The multispectral optoacoustic imaging allowed for spectroscopic differentiation of lipid content, as well as the bio-distributions of oxygenated and deoxygenated hemoglobin in liver tissues in vivo. The pulse-echo (reflection) ultrasound (US) imaging further provided a valuable anatomical reference whilst transmission US facilitated the mapping of speed of sound changes in lipid-rich regions, which was consistent with the presence of macrovesicular hepatic steatosis in the NAFLD livers examined with ex vivo histological staining. Conclusion: The proposed multimodal approach facilitates quantification of liver abnormalities at early stages using a variety of optical and acoustic contrasts, laying the ground for translating the TROPUS approach toward diagnosis and monitoring NAFLD in patients.ISSN:1838-764