95 research outputs found
Råpidas reaçÔes evasivas de copépodes (Copepoda, Calanoida) evitam a predação por medusas juvenis de Lychnorhiza lucerna (Scyphozoa, Rhizostomeae)
Fundação de Amparo Ă Pesquisa do Estado de SĂŁo Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de NĂvel Superior (CAPES)NĂșcleo de Pesquisa em Biodiversidade Marinha da Universidade de SĂŁo Paulo (NP-BioMar/USP
Absence of association between pyronaridine in vitro responses and polymorphisms in genes involved in quinoline resistance in Plasmodium falciparum
<p>Abstract</p> <p>Background</p> <p>The aim of the present work was to assess the <it>in vitro </it>cross-resistance of pyronaridine with other quinoline drugs, artesunate and several other commonly used anti-malarials and to evaluate whether decreased susceptibility to pyronaridine could be associated with genetic polymorphisms in genes involved in reduced quinoline susceptibility, such as <it>pfcrt</it>, <it>pfmdr1</it>, <it>pfmrp </it>and <it>pfnhe</it>.</p> <p>Methods</p> <p>The <it>in vitro </it>chemosusceptibility profiles of 23 strains of <it>Plasmodium falciparum </it>were analysed by the standard 42-hour <sup>3</sup>H-hypoxanthine uptake inhibition method for pyronaridine, artesunate, chloroquine, monodesethylamodiaquine, quinine, mefloquine, lumefantrine, atovaquone, pyrimethamine and doxycycline. Genotypes were assessed for <it>pfcrt</it>, <it>pfmdr1</it>, <it>pfnhe-1 </it>and <it>pfmrp </it>genes.</p> <p>Results</p> <p>The IC<sub>50 </sub>values for pyronaridine ranged from 15 to 49 nM (geometric mean = 23.1 nM). A significant positive correlation was found between responses to pyronaridine and responses to artesunate (<it>r<sup>2 </sup></it>= 0.20; <it>P </it>= 0.0317) but too low to suggest cross-resistance. No significant correlation was found between pyronaridine IC<sub>50 </sub>and responses to other anti-malarials. Significant associations were not found between pyronaridine IC<sub>50 </sub>and polymorphisms in <it>pfcrt</it>, <it>pfmdr1</it>, <it>pfmrp </it>or <it>pfnhe-1</it>.</p> <p>Conclusion</p> <p>There was an absence of cross-resistance between pyronaridine and quinolines, and the IC<sub>50 </sub>values for pyronaridine were found to be unrelated to mutations in the transport protein genes <it>pfcrt</it>, <it>pfmdr1</it>, <it>pfmrp </it>or <it>pfnhe-1</it>, known to be involved in quinoline resistance. These results confirm the interest and the efficacy of the use of a combination of pyronaridine and artesunate in areas in which parasites are resistant to quinolines.</p
Thiamine Diphosphate in Whole Blood, Thiamine and Thiamine Monophosphate in Breast-Milk in a Refugee Population
BACKGROUND: The provision of high doses of thiamine may prevent thiamine deficiency in the post-partum period of displaced persons. METHODOLOGY/PRINCIPAL FINDINGS: The study aimed to evaluate a supplementation regimen of thiamine mononitrate (100 mg daily) at the antenatal clinics in Maela refugee camp. Women were enrolled during antenatal care and followed after delivery. Samples were collected at 12 weeks post partum. Thiamine diphosphate (TDP) in whole blood and thiamine in breast-milk of 636 lactating women were measured. Thiamine in breast-milk consisted of thiamine monophosphate (TMP) in addition to thiamine, with a mean TMP to total thiamine ratio of 63%. Mean whole blood TDP (130 nmol/L) and total thiamine in breast-milk (755 nmol/L) were within the upper range reported for well-nourished women. The prevalence of women with low whole blood TDP (<65 nmol/L) was 5% and with deficient breast-milk total thiamine (<300 nmol/L) was 4%. Whole blood TDP predicted both breast-milk thiamine and TMP (R(2)â=â0.36 and 0.10, p<0.001). A ratio of TMP to total thiamine â„63% was associated with a 7.5 and 4-fold higher risk of low whole blood TDP and deficient total breast-milk thiamine, respectively. Routine provision of daily 100 mg of thiamine mononitrate post-partum compared to the previous weekly 10 mg of thiamine hydrochloride resulted in significantly higher total thiamine in breast-milk. CONCLUSIONS/SIGNIFICANCE: Thiamine supplementation for lactating women in Maela refugee camp is effective and should be continued. TMP and its ratio to total thiamine in breast-milk, reported for the first time in this study, provided useful information on thiamine status and should be included in future studies of breast-milk thiamine
Micronutrient status in lactating mothers before and after introduction of fortified flour: cross-sectional surveys in Maela refugee camp
Background Deficiency of micronutrients is common in refugee populations. Objectives Identify deficiencies and whether provided supplements and wheat flour fortified with 10 micronutrients impacts upon status among breast-feeding women from Maela refugee camp. Methods Two sequential cross-sectional studies were conducted in different groups of lactating mothers at 12 weeks postpartum. The first survey was before and the second 4-5 months after micronutrient fortified flour (MFF) had been provided to the camp (in addition to the regular food basket). Iron status and micronutrients were measured in serum, whole blood, and in breast milk samples. Results Iron and zinc deficiency and anemia were highly prevalent while low serum retinol and thiamine deficiency were rarely detected. Iron and zinc deficiency were associated with anemia, and their proportions were significantly lower after the introduction of MFF (21 vs. 35% with soluble transferrin receptor (sTfR)>8.5 mg/L, P = 0.042, and 50 vs. 73% with serum zinc<0.66 mg/L, P = 0.001). Serum sTfR, whole-blood thiamine diphosphate (TDP) and serum ÎČ-carotene were significant predictors (P<0.001) of milk iron, thiamine and ÎČ-carotene, respectively. Lower prevalence of iron deficiency in the MFF group was associated with significantly higher iron and thiamine in breast milk. Conclusions High whole-blood TDP and breast milk thiamine reflected good compliance to provided thiamine; high prevalence of iron deficiency suggested insufficient dietary iron and low acceptance to ferrous sulfate supplements. MFF as an additional food ration in Maela refugee camp seemed to have an effect in reducing both iron and zinc deficiency postpartum. © Springer-Verlag 2012
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Measurements of electrons from interactions are crucial for the Deep
Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as
searches for physics beyond the standard model, supernova neutrino detection,
and solar neutrino measurements. This article describes the selection and
reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector.
ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and
operated at CERN as a charged particle test beam experiment. A sample of
low-energy electrons produced by the decay of cosmic muons is selected with a
purity of 95%. This sample is used to calibrate the low-energy electron energy
scale with two techniques. An electron energy calibration based on a cosmic ray
muon sample uses calibration constants derived from measured and simulated
cosmic ray muon events. Another calibration technique makes use of the
theoretically well-understood Michel electron energy spectrum to convert
reconstructed charge to electron energy. In addition, the effects of detector
response to low-energy electron energy scale and its resolution including
readout electronics threshold effects are quantified. Finally, the relation
between the theoretical and reconstructed low-energy electron energy spectrum
is derived and the energy resolution is characterized. The low-energy electron
selection presented here accounts for about 75% of the total electron deposited
energy. After the addition of lost energy using a Monte Carlo simulation, the
energy resolution improves from about 40% to 25% at 50~MeV. These results are
used to validate the expected capabilities of the DUNE far detector to
reconstruct low-energy electrons.Comment: 19 pages, 10 figure
Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is
to measure the MeV neutrinos produced by a Galactic
core-collapse supernova if one should occur during the lifetime of the
experiment. The liquid-argon-based detectors planned for DUNE are expected to
be uniquely sensitive to the component of the supernova flux, enabling
a wide variety of physics and astrophysics measurements. A key requirement for
a correct interpretation of these measurements is a good understanding of the
energy-dependent total cross section for charged-current
absorption on argon. In the context of a simulated extraction of
supernova spectral parameters from a toy analysis, we investigate the
impact of modeling uncertainties on DUNE's supernova neutrino
physics sensitivity for the first time. We find that the currently large
theoretical uncertainties on must be substantially reduced
before the flux parameters can be extracted reliably: in the absence of
external constraints, a measurement of the integrated neutrino luminosity with
less than 10\% bias with DUNE requires to be known to about 5%.
The neutrino spectral shape parameters can be known to better than 10% for a
20% uncertainty on the cross-section scale, although they will be sensitive to
uncertainties on the shape of . A direct measurement of
low-energy -argon scattering would be invaluable for improving the
theoretical precision to the needed level.Comment: 25 pages, 21 figure
Descontinuidades e ressurgĂȘncias: entre o normal e o patolĂłgico na teoria do controle social
Highly-parallelized simulation of a pixelated LArTPC on a GPU
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype
Prevalence of chronic ocular complications in Stevens-Johnson syndrome and toxic epidermal necrolysis
Error detection thresholds for routine real time in vivo dosimetry in HDR prostate brachytherapy
Purpose: Routine real time in vivo dosimetry (IVD) is performed in HDR prostate brachytherapy to independently verify dose delivery. This study investigates impact of position uncertainty on error detection thresholds for IVD.
Methods: IVD is implemented using a microMOSFET placed centrally in the prostate using an additional needle. 144 IVD measurements were made for 15Gy or 19Gy single fraction treatments. Needle insertion and treatment planning used real-time trans-rectal ultrasound. Source-MOSFET position thresholds of ±1, ±2 and ±3mm were used to calculate per-needle and total plan error detection thresholds for the measured dose using an uncertainty analysis based on the treatment plan data.
Results: The median dose difference from 144 total plan measurements was â5.2% (range +7.4% to â17.3%). 8 plans measured outside the total plan error detection threshold for position threshold ±1mm, no plans measured outside the total plan error detection threshold for larger position thresholds. For 2233 individual needle measurements, for position thresholds of ±1mm, ±2mm and ±3mm the number of needles outside the per-needle error detection threshold was 103, 25 and 10 respectively and the number of treatments that would have required interruption based on these thresholds for real-time IVD was 66, 16 and 8 respectively.
Conclusion: IVD in HDR prostate brachytherapy using a microMOSFET provides a high level of confidence that we are correctly delivering the planned dose to our patients. A ±2-3mm position threshold gives an appropriate balance between error detection and avoiding unnecessary treatment interruptions
- âŠ