710 research outputs found

    A novel copper precursor for electron beam induced deposition

    Get PDF
    A fluorine free copper precursor, Cu(tbaoac)2 with the chemical sum formula CuC16O6H26 is introduced for focused electron beam induced deposition (FEBID). FEBID with 15 keV and 7 nA results in deposits with an atomic composition of Cu:O:C of approximately 1:1:2. Transmission electron microscopy proved that pure copper nanocrystals with sizes of up to around 15 nm were dispersed inside the carbonaceous matrix. Raman investigations revealed a high degree of amorphization of the carbonaceous matrix and showed hints for partial copper oxidation taking place selectively on the surfaces of the deposits. Optical transmission/reflection measurements of deposited pads showed a dielectric behavior of the material in the optical spectral range. The general behavior of the permittivity could be described by applying the Maxwell–Garnett mixing model to amorphous carbon and copper. The dielectric function measured from deposited pads was used to simulate the optical response of tip arrays fabricated out of the same precursor and showed good agreement with measurements. This paves the way for future plasmonic applications with copper-FEBID

    A Fast Sextupole Probe for Snapback Measurement in the LHC Dipoles

    Get PDF
    In superconducting particle accelerators a fast change of the magnetic field occurs during the first few seconds after the start of an energy ramp. Standard magnetic measurements using a coil rotating at 1 Hz do not have the time resolution required to completely resolve this phase, usually called snapback. For this reason we have developed a new and fast system dedicated to sextupole measurements. The basic component consists of three Hall plates mounted on a ring. In an ideal case this arrangement compensates the main dipole field and produces a signal proportional to the sextupole only. Mechanical tolerances and differences in the sensitivity of the Hall plates are compensated by instrumentation amplifiers and an in situ fine adjustment of the probe orientation. Using this hybrid compensation technique we have measured sextupole variations in an LHC dipole prototype during snapback at a rate of 5 Hz. In this paper we present details on the device and the results of our measurements

    Relative timing jitter measurements with an indirect phase comparison method

    Get PDF
    We propose and demonstrate experimentally a method for the sensitive measurement of the relative timing jitter of two mode-locked lasers, which can be either free-running or timing-synchronized to a common reference oscillator. The method is based on the indirect comparison of the phases of two photodetector outputs, using a microwave oscillator, the noise of which does not affect the results, electronic mixers, and a sampling oscilloscope. We carefully analyze and experimentally demonstrate the potential of this method. Compared to phase detector methods, it has a broader scope of applications and a lower sensitivity to intensity noise. We also obtained data on the coupling of intensity to timing noise in photodetector

    Intramedullary nailing versus sliding hip screw for A1 and A2 trochanteric hip fractures

    Get PDF
    AIMS: This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). METHODS: A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. RESULTS: The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1 fractures (Type A2 OR 10 (95% CI 8.4 to 12); p < 0.001). CONCLUSION: In an international cohort of orthopaedic surgeons, there was a large variation in implant preference for patients with A1 and A2 trochanteric fractures. This is due to surgeon bias (country of practice and aspects of training). The observation that surgeons favoured the more expensive implant (IMN) in the absence of convincing evidence of its superiority suggests that surgeon de-biasing strategies may be a useful focus for optimizing patient outcomes and promoting value-based healthcare. Cite this article: Bone Joint J 2021;103-B(4):775-781

    The Harris hip score: Do ceiling effects limit its usefulness in orthopedics?: A systematic review

    Get PDF
    The Harris hip score (HHS), a disease-specific health status scale that is frequently used to measure the outcome of total hip arthroplasty, has never been validated properly. A questionnaire is suitable only when all 5 psychometric properties are of sufficient quality. We questioned the usefulness of the HHS by investigating its content validity. We performed a systematic review based on a literature search in PubMed, Embase, and the Cochrane Library for descriptive studies published in 2007. 54 studies (59 patient groups) met our criteria and were included in the data analysis. To determine the content validity, we calculated the ceiling effect (percentage) for each separate study and we pooled data to measure the weighted mean. A subanalysis of indications for THA was performed to differentiate the populations for which the HHS would be suitable and for which it would not. A ceiling effect of 15% or less was considered to be acceptable. Over half the studies (31/59) revealed unacceptable ceiling effects. Pooled data across the studies included (n = 6,667 patients) suggested ceiling effects of 20% (95%CI: 18-22). Ceiling effects were greater (32%, 95%CI:12-52) in those patients undergoing hip resurfacing arthroplasty. Although the Harris hip score is widely used in arthroplasty research on outcomes, ceiling effects are common and these severely limit its validity in this field of researc

    Advances for Treating in-Hospital Cardiac Arrest: Safety and Effectiveness of a New Automatic External Cardioverter-Defibrillator

    Get PDF
    OBJECTIVES: The purpose of this study was to prospectively analyze the performance and safety of a new programmable, fully automatic external cardioverter-defibrillator (AECD) in a European multicenter trial. BACKGROUND Although, the response time to cardiac arrest (CA) is a major determinant of mortality and morbidity, in-hospital strategies have not significantly changed during the last 30 years. METHODS: Patients (n = 117) at risk of CA in monitored wards (n = 51) and patients undergoing electrophysiologic testing or implantable cardioverter-defibrillator (ICD) implantation (n = 66) were enrolled. The accuracy of the automatic response of the device to any change of rhythm (lasting >1 s and >4 beats) was confirmed by reviewing the simultaneously recorded Holter data and the programmed parameters. RESULTS: During 1,240 h, 1,988 episodes of rhythm changes were documented. A total of 115 episodes lasted > or =10 s or needed treatment (pacing, n = 32; ICD, n = 51; AECD, n = 35) for termination. The device detected ventricular tachyarrhythmias with a sensitivity of 100% and specificity of 97.6% (true negatives, n = 1,454; true positives, n = 499; false positives, n = 35; false negatives, n = 0). The false positives were all caused by T-wave oversensing during ventricular pacing. There were no complications or adverse events. The mean response time was 14.4 s for those episodes needing a full charge of the capacitor. CONCLUSIONS: This new AECD is safe and effective in detecting, monitoring, and treating spontaneous arrhythmias. This fully automatic device shortens the response time to treatment, and it is likely that it will significantly improve the outcome of patients with in-hospital CA

    Seizure-Related Gene 6 (Sez-6) in Amacrine Cells of the Rodent Retina and the Consequence of Gene Deletion

    Get PDF
    Background: Seizure-related gene 6 (Sez-6) is expressed in neurons of the mouse brain, retina and spinal cord. In the cortex, Sez-6 plays a role in specifying dendritic branching patterns and excitatory synapse numbers during development. Methodology/Principal Findings: The distribution pattern of Sez-6 in the retina was studied using a polyclonal antibody that detects the multiple isoforms of Sez-6. Prominent immunostaining was detected in GABAergic, but not in All glycinergic, amacrine cell subpopulations of the rat and mouse retina. Amacrine cell somata displayed a distinct staining pattern with the Sez-6 antibody: a discrete, often roughly triangular-shaped bright spot positioned between the nucleus and the apical dendrite superimposed over weaker general cytoplasmic staining. Displaced amacrines in the ganglion cell layer were also positive for Sez-6 and weaker staining was occasionally observed in neurons with the morphology of alpha ganglion cells. Two distinct Sez-6 positive strata were present in the inner plexiform layer in addition to generalized punctate staining. Certain inner nuclear layer cells, including bipolar cells, stained more weakly and diffusely than amacrine cells, although some bipolar cells exhibited a perinuclear "bright spot" similar to amacrine cells. In order to assess the role of Sez-6 in the retina, we analyzed the morphology of the Sez-6 knockout mouse retina with immunohistochemical markers and compared ganglion cell dendritic arbor patterning in Sez-6 null retinae with controls. The functional importance of Sez-6 was assessed by dark-adapted paired-flash electroretinography (ERG). Conclusions: In summary, we have reported the detailed expression pattern of a novel retinal marker with broad cell specificity, useful for retinal characterization in rodent experimental models. Retinal morphology, ganglion cell dendritic branching and ERG waveforms appeared normal in the Sez-6 knockout mouse suggesting that, in spite of widespread expression of Sez-6, retinal function in the absence of Sez-6 is not affected

    Incorporating lessons from high-input research into a low-margin year

    Get PDF
    Increased soybean commodity prices in recent years have generated interest in developing high-input systems to increase yield. However, little information exists about the effects of input-intensive, high-yield management on soybean yield and profitability, as well as interactions with basic agronomic practices

    Fundamental electronic changes upon intersystem crossing in large aromatic photosensitizers free base 5,10,15,20 tetrakis 4 carboxylatophenyl porphyrin

    Get PDF
    Free base 5,10,15,20 tetrakis 4 carboxylatophenyl porphyrin stands for the class of powerful porphyrin photosensitizers for singlet oxygen generation and light harvesting. The atomic level selectivity of dynamic UV pump N K edge probe X ray absorption spectroscopy in combination with time dependent density functional theory TD DFT gives direct access to the crucial excited molecular states within the unusual relaxation pathway. The efficient intersystem crossing, that is El Sayed forbidden and not facilitated by a heavy atom is confirmed to be the result of the long singlet excited state lifetime Qx 4.9 ns and thermal effects. Overall, the interplay of stabilization by conservation of angular momenta and vibronic relaxation drive the de excitation in these chromophore
    • …
    corecore