124 research outputs found

    The Nordic Arthroplasty Register Association: A unique collaboration between 3 national hip arthroplasty registries with 280,201 THRs

    Get PDF
    Background and purpose The possibility of comparing results and of pooling the data has been limited for the Nordic arthroplasty registries, because of different registration systems and questionnaires. We have established a common Nordic database, in order to compare demographics and the results of total hip replacement surgery between countries. In addition, we plan to study results in patient groups in which the numbers are too small to be studied in the individual countries

    No bias of ignored bilaterality when analysing the revision risk of knee prostheses: Analysis of a population based sample of 44,590 patients with 55,298 knee prostheses from the national Swedish Knee Arthroplasty Register

    Get PDF
    BACKGROUND: The current practice of the Swedish Knee Register is not to take into consideration if one or both knees in a patient are subject to surgery when evaluating risk of revision after arthroplasty. Risk calculations are typically done by statistical methods, such as Kaplan-Meier analyses and Cox's proportional hazards models, that are based on the assumption that observed events are independent, and this is rarely appreciated. The purpose of this study was to investigate if ignoring bilateral operations when using these methods biases the results. METHODS: The bias of not taking bilateral operations into account was investigated by statistically analysing 55 298 prostheses in 44 590 patients, undergoing knee arthroplasty surgery in Sweden during 1985–1999, using traditional proportional hazards analysis, which assumes that all observations are independent, and a shared gamma frailty model, which allows patients to contribute repeated observations. RESULTS: The effect of neglecting bilateral prostheses is minute, possibly because bilateral prosthesis failure is a rare event. CONCLUSION: We conclude that the revision risk of knee prostheses in general can be analysed without consideration for subject dependency, at least in study populations with a relatively low proportion of subjects having experienced bilateral revisions

    Statistical analysis of arthroplasty data: II. Guidelines

    Get PDF
    It is envisaged that guidelines for statistical analysis and presentation of results will improve the quality and value of research. The Nordic Arthroplasty Register Association (NARA) has therefore developed guidelines for the statistical analysis of arthroplasty register data. The guidelines are divided into two parts, one with an introduction and a discussion of the background to the guidelines (Ranstam et al. 2011a, see pages x-y in this issue), and this one with a more technical statistical discussion on how specific problems can be handled. This second part contains (1) recommendations for the interpretation of methods used to calculate survival, (2) recommendations on howto deal with bilateral observations, and (3) a discussion of problems and pitfalls associated with analysis of factors that influence survival or comparisons between outcomes extracted from different hospitals

    Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register

    Get PDF
    Background and purpose: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods: Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results: Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0– 97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation: With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation

    MOBILE and the provision of total joint replacement

    Get PDF
    Modern joint replacements have been available for 45 years, but we still do not have clear indications for these interventions, and we do not know how to optimize the outcome for patients who agree to have them done. The MOBILE programme has been investigating these issues in relation to primary total hip and knee joint replacements, using mixed methods research

    Risk factors for revision after shoulder arthroplasty: 1,825 shoulder arthroplasties from the Norwegian Arthroplasty Register

    Get PDF
    Background and purpose Previous studies on shoulder arthroplasty have usually described small patient populations, and few articles have addressed the survival of shoulder implants. We describe the results of shoulder replacement in the Norwegian population (of 4.7 million) during a 12-year period. Trends in the use of shoulder arthroplasty during the study period were also investigated

    Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty 163,368 hip replacements in the Nordic Arthroplasty Register Association database with 5-11 years of follow-up

    Get PDF
    Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis.Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups).Results - The CPE version of the ZCA cup had a risk of revision for any reason similar to that of the XLPE version (p = 0.09), but showed a 6-fold higher risk of revision for aseptic loosening (p < 0.001). The CPE version of the Reflection All Poly cup had an 8-fold elevated risk of revision for any reason (p < 0.001) and a 5-fold increased risk of revision for aseptic loosening (p < 0.001). The Charnley Elite Ogee/Marathon cup and the Trilogy cup did not show such differences.Interpretation Whether XLPE has any advantage over CPE regarding revision risk may depend on the properties of the polyethylene materials being compared, as well as the respective cup designs, fixation type, and follow-up times. Further research is needed to elucidate how cup design factors interact with polyethylene type to affect the risk of revision
    corecore