1,197 research outputs found

    Camera-based in-process quality measurement of hairpin welding

    Get PDF
    The technology of hairpin welding, which is frequently used in the automotive industry, entails high-quality requirements in the welding process. It can be difficult to trace the defect back to the affected weld if a non-functioning stator is detected during the final inspection. Often, a visual assessment of a cooled weld seam does not provide any information about its strength. However, based on the behavior during welding, especially about spattering, conclusions can be made about the quality of the weld. In addition, spatter on the component can have serious consequences. In this paper, we present in-process monitoring of laser-based hairpin welding. Using an in-process image analyzed by a neural network, we present a spatter detection method that allows conclusions to be drawn about the quality of the weld. In this way, faults caused by spattering can be detected at an early stage and the affected components sorted out. The implementation is based on a small data set and under consideration of a fast process time on hardware with limited computing power. With a network architecture that uses dilated convolutions, we obtain a large receptive field and can therefore consider feature interrelation in the image. As a result, we obtain a pixel-wise classifier, which allows us to infer the spatter areas directly on the production lines

    Energy Dissipation on Stepped Spillways

    Get PDF
    The author provided interesting data on stepped spillway flows. The writer would like to add some information on flow resistance of skimming flows and discuss the energy dissipation on stepped chutes. It will be shown that the author's results are not dissimilar with results previously obtained by other researchers

    Local bifurcations in differential equations with state-dependent delay

    Get PDF
    This is the author accepted manuscript. The final version is available from AIP Publishing via the DOI in this record.A common task when analysing dynamical systems is the determination of normal forms near local bifurcations of equilibria. As most of these normal forms have been classified and analysed, finding which particular class of normal form one encounters in a numerical bifurcation study guides follow-up computations. This paper builds on normal form algorithms for equilibria of delay differential equations with constant delay that were developed and implemented in DDE-Biftool recently. We show how one can extend these methods to delay-differential equations with state-dependent delay (sd-DDEs). Since higher degrees of regularity of local center manifolds are still open for sd-DDEs, we give an independent (still only partial) argument which phenomena from the truncated normal must persist in the full sd-DDE. In particular, we show that all invariant manifolds with a sufficient degree of normal hyperbolicity predicted by the normal form exist also in the full sd-DDEJ.S. gratefully acknowledges the financial support of the EPSRC via grants EP/N023544/1 and EP/N014391/1. J.S. has also received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement number 643073

    Are Laparoscopic Staplers Effective for Ligation of Large Intraabdominal Arteries?

    Get PDF
    AbstractObjectives. To evaluate ligation of aortoiliac arteries with laparoscopic staplers in order to develop specifically designed staplers.Methods. Cadaveric study. Seven human cadaver aortas were stapled using EndoGIA60Âź staplers. Efficiency was evaluated macroscopically and on a hydrodynamic bench.Clinical study. Twelve patients had ligation of 14 large abdominal arteries (aorta: nine, iliac artery: four, hepatic artery: one) using a laparoscopic stapler. Stapling efficiency was judged on peroperative clinical and postoperative CT scan criteria.Results. Cadaveric study. Stapling was performed perfectly on four moderately calcified aortas, without leakage with a pulsatile pressure of >250 mmHg. For three aortas with severe calcification, stapling was not efficient and major leakage occurred.Clinical study. Stapling appeared clinically efficient on all arteries but one aorta: this severely calcified aorta was ligated conventionally. The staplers are not easy to use due to their shape and their lack of articulation. After a mean follow-up of 31.3 months, all the other stapled arteries were effectively ligated.Conclusion. The commercially available staplers can be used securely on moderately calcified arteries but stapling of severely calcified arteries should be avoided. These devices should be redesigned to facilitate their use in vascular surgery

    Risk Factor Analysis of Bird Beak Occurrence after Thoracic Endovascular Aortic Repair

    Get PDF
    ObjectivesThe aim was to analyze the role played by anatomy and stent graft in the incidence of incomplete apposition to aortic arch.MethodsBetween 2007 and 2014 data including available and suitable computed tomographic angiography (CTA) imaging of patients who had undergone thoracic endovascular aortic repair were reviewed. The study included 80 patients (65 men, 54 ± 21 years) treated for traumatic aortic rupture (n = 27), thoracic aortic aneurysm (n = 15), type B aortic dissection (n = 24), penetrating aortic ulcer (n = 5), intramural hematoma (n = 2), aorto-oesophageal fistula (n = 2), and aortic mural thrombus (n = 5). Pre- and post-operative CTA images were analyzed to characterize bird beak in terms of length and angle, and to calculate aortic angulation within a 30 mm range at the proximal deployment zone.ResultsBird beak configuration was detected in 46 patients (57%): mean stent protrusion length was 16 mm (range: 8–29 mm) and mean bird beak angle was 20° (range: 7–40°). The bird beak effect was significantly more frequent after traumatic aortic rupture treatment (p = .05) and in landing zone 2 (p = .01). No influence of either stent graft type or generation, or degree of oversizing was observed (p = .29, p = .28, p = .81 respectively). However, the mean aortic angle of patients with bird beak was higher in the Pro-form group than that in the Zenith TX2 group (62° vs. 48°, p = .13). Multivariate analysis identified the aortic angle of the deployment zone as the unique independent risk factor of malapposition (HR = 1.05, 95% CI 1–1.10, p = .005). The cutoff value of 51° was found to be predictive of bird beak occurrence with a sensitivity of 58% and a specificity of 85%.ConclusionsAssessment of proximal landing zone morphology to avoid deployment zones generating an aortic angle of over 50° can be recommended to improve aortic curvature apposition with the current available devices

    Endovascular Stent Treatment for Symptomatic Benign Iliofemoral Venous Occlusive Disease: Long-Term Results 1987–2009

    Get PDF
    Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18–66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical result was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0–70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0–70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0–48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0–47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate

    A nondestructive Bell-state measurement on two distant atomic qubits

    Get PDF
    • 

    corecore