145 research outputs found

    Role of the Delta Resonance in the Population of a Four-Nucleon State in the 56Fe to 54Fe Reaction at Relativistic Energies

    Get PDF
    The 54Fe nucleus was populated from a 56Fe beam impinging on a Be target with an energy of E/A=500MeV. The internal decay via γ-ray emission of the 10+ metastable state was observed. As the structure of this isomeric state has to involve at least four unpaired nucleons, it cannot be populated in a simple two-neutron removal reaction from the 56Fe ground state. The isomeric state was produced in the low-momentum (-energy) tail of the parallel momentum (energy) distribution of 54Fe, suggesting that it was populated via the decay of the Δ0 resonance into a proton. This process allows the population of four-nucleon states, such as the observed isomer. Therefore, it is concluded that the observation of this 10+ metastable state in 54Fe is a consequence of the quark structure of the nucleons

    Characterisation of a small electrode HPGe detector

    Get PDF
    © 2019 Elsevier B.V. Small electrode HPGe detectors in an inverted coaxial geometry are increasingly in use in applications where both high efficiency and excellent energy resolution are required. The unusual electric field configuration of these detectors results in extremely long charge collection times compared to planar and coaxial devices. In this work we have characterised such a detector using gamma-ray coincidence measurements and optimised an electric field simulation to reproduce the positional variation of detector response. We show that, alongside accurate crystal geometry and applied electric potential, a temperature correction is crucial to correctly determining appropriate charge carrier mobility parameters. This work will help to guide the future development of HPGE detectors for applications including radioactive waste assay, radio-isotope dating, and fundamental nuclear physics

    Characterisation of a CZT detector for dosimetry of molecular radiotherapy

    Get PDF
    A pixelated cadmium zinc telluride (CZT) detector has been characterised for the purpose of developing a quantitative single photon emission computed tomography (SPECT) system for dosimetry of molecular radiotherapy (MRT). This is the aim of the Dosimetric Imaging with CZT (DEPICT) project, which is a collaboration between the University of Liverpool, The Royal Marsden Hospital, The Royal Liverpool and Broadgreen University Hospital, and the commercial partner Kromek. CZT is a direct band gap semiconductor with superior energy resolution and stopping power compared to scintillator detectors used in current SPECT systems. The inherent detector properties have been investigated and operational parameters such as bias voltage and peaking time have been selected to optimise the performance of the system. Good energy resolution is required to discriminate Îł-rays that are scattered as they are emitted from the body and within the collimator, and high photon throughput is essential due to the high activities of isotopes administered in MRT. The system has an average measured electronic noise of 3.31 keV full width at half maximum (FWHM), determined through the use of an internal pulser. The energy response of the system was measured across the energy region of interest 59.5 keV to 364.5 keV and found to be linear. The reverse bias voltage and peaking time producing the optimum FWHM and maximum photon throughput were 600 V and 0.5 ÎĽs respectively. The average dead time of the system was measured as 4.84 ÎĽs and charge sharing was quantified to be 0.71 % at 59.5 keV . A pixel sensitivity calibration map was created and planar images of the medical imaging isotopes 99mTc and 123I were acquired by coupling the device to a prototype collimator, thereby demonstrating the suitability of the detector for the DEPICT project

    Investigation of attentional bias in obsessive compulsive disorder with and without depression in visual search

    Get PDF
    Copyright: © 2013 Morein-Zamir et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are creditedWhether Obsessive Compulsive Disorder (OCD) is associated with an increased attentional bias to emotive stimuli remains controversial. Additionally, it is unclear whether comorbid depression modulates abnormal emotional processing in OCD. This study examined attentional bias to OC-relevant scenes using a visual search task. Controls, non-depressed and depressed OCD patients searched for their personally selected positive images amongst their negative distractors, and vice versa. Whilst the OCD groups were slower than healthy individuals in rating the images, there were no group differences in the magnitude of negative bias to concern-related scenes. A second experiment employing a common set of images replicated the results on an additional sample of OCD patients. Although there was a larger bias to negative OC-related images without pre-exposure overall, no group differences in attentional bias were observed. However, OCD patients subsequently rated the images more slowly and more negatively, again suggesting post-attentional processing abnormalities. The results argue against a robust attentional bias in OCD patients, regardless of their depression status and speak to generalized difficulties disengaging from negative valence stimuli. Rather, post-attentional processing abnormalities may account for differences in emotional processing in OCD.Peer reviewedFinal Published versio

    Nuclear structure of Au-181 studied via beta(+)/EC decay of Hg-181 at ISOLDE

    Get PDF
    The β+\beta ^+/EC decay of mass separated samples of 181^{181}Hg was studied employing the TATRA spectrometer at the ISOLDE facility at CERN. The decay scheme was constructed for the first time. A Broad Energy Germanium detector was used to achieve this by combination of high-gain γ\gamma -ray singles spectroscopy and γ\gamma –γ\gamma  coincidences. The systematics of excited states associated with the 1h11/2h_{11/2} proton-hole configuration in odd-Au isotopes was extended

    Beta-delayed proton emission from 20Mg

    Get PDF
    Beta-delayed proton emission from 20 Mg has been measured at ISOLDE, CERN, with the ISOLDE Decay Station (IDS) setup including both charged-particle and gamma-ray detection capabilities. A total of 27 delayed proton branches were measured including seven so far unobserved. An updated decay scheme, including three new resonances above the proton separation energy in 20 Na and more precise resonance energies, is presented. Beta-decay feeding to two resonances above the Isobaric Analogue State (IAS) in 20 Na is observed. This may allow studies of the 4032.9(2.4)keV resonance in 19 Ne through the beta decay of 20 Mg, which is important for the astrophysically relevant reaction 15O( α \alpha , γ \gamma )19Ne . Beta-delayed protons were used to obtain a more precise value for the half-life of 20 Mg, 91.4(1.0)ms

    Fast-timing study of the l -forbidden 12+→32+ M1 transition in Sn 129 FAST-TIMING STUDY of the l -FORBIDDEN ⋯ R. LICǎ et al.

    Get PDF
    © 2016 authors. Published by the American Physical Society.The levels in Sn129 populated from the β- decay of In129 isomers were investigated at the ISOLDE facility of CERN using the newly commissioned ISOLDE Decay Station (IDS). The lowest 12+ state and the 32+ ground state in Sn129 are expected to have configurations dominated by the neutron s12 (l=0) and d32 (l=2) single-particle states, respectively. Consequently, these states should be connected by a somewhat slow l-forbidden M1 transition. Using fast-timing spectroscopy we have measured the half-life of the 12+ 315.3-keV state, T12= 19(10) ps, which corresponds to a moderately fast M1 transition. Shell-model calculations using the CD-Bonn effective interaction, with standard effective charges and g factors, predict a 4-ns half-life for this level. We can reconcile the shell-model calculations to the measured T12 value by the renormalization of the M1 effective operator for neutron holes
    • …
    corecore