58 research outputs found

    Applicability and usage of dose mapping/accumulation in radiotherapy

    Get PDF
    Dose mapping/accumulation (DMA) is a topic in radiotherapy (RT) for years, but has not yet found its widespread way into clinical RT routine. During the ESTRO Physics workshop 2021 on "commissioning and quality assurance of deformable image registration (DIR) for current and future RT applications", we built a working group on DMA from which we present the results of our discussions in this article. Our aim in this manuscript is to shed light on the current situation of DMA in RT and to highlight the issues that hinder consciously integrating it into clinical RT routine. As a first outcome of our discussions, we present a scheme where representative RT use cases are positioned, considering expected anatomical variations and the impact of dose mapping uncertainties on patient safety, which we have named the DMA landscape (DMAL). This tool is useful for future reference when DMA applications get closer to clinical day-to-day use. Secondly, we discussed current challenges, lightly touching on first-order effects (related to the impact of DIR uncertainties in dose mapping), and focusing in detail on second-order effects often dismissed in the current literature (as resampling and interpolation, quality assurance considerations, and radiobiological issues). Finally, we developed recommendations, and guidelines for vendors and users. Our main point include: Strive for context-driven DIR (by considering their impact on clinical decisions/judgements) rather than perfect DIR; be conscious of the limitations of the implemented DIR algorithm; and consider when dose mapping (with properly quantified uncertainties) is a better alternative than no mapping

    NaF PET/CT for response assessment of prostate cancer bone metastases treated with single fraction stereotactic ablative body radiotherapy

    Get PDF
    Introduction: In prostate cancer patients, imaging of bone metastases is enhanced through the use of sodium fluoride positron emission tomography (18F-NaF PET/CT). This imaging technique shows areas of enhanced osteoblastic activity and blood flow. In this work, 18F-NaF PET/CT was investigated for response assessment to single fraction stereotactic ablative body radiotherapy (SABR) to bone metastases in prostate cancer patients. Methods: Patients with bone metastases in a prospective trial treated with single fraction SABR received a 18F-NaF PET/CT scan prior to and 6 months post-SABR. The SUVmax in the tumour was determined and the difference between before and after SABR determined. The change in uptake in the non-tumour bone was also measured as a function of the received SABR dose. Results: Reduction in SUVmax was observed in 29 of 33 lesions 6 months after SABR (mean absolute decrease in SUVmax 17.7, 95% CI 25.8 to - 9.4, p = 0.0001). Of the three lesions with increased SUVmax post-SABR, two were from the same patient and located in the vertebral column. Both were determined to be local progression in addition to one fracture. The third lesion (in a rib) was shown to be controlled locally but suffered from a fracture at 24 months. Progression adjacent to the treated volume was observed in two patients. The non-tumour bone irradiated showed increased loss in uptake with increasing dose, with a median loss in uptake of 23.3% for bone receiving 24 Gy. Conclusion: 18F-NaF PET/CT for response assessment of bone metastases to single fraction SABR indicates high rates of reduction of osteoblastic activity in the tumour and non-tumour bone receiving high doses. The occurrence of marginal recurrence indicates use of larger clinical target volumes may be warranted in treatment of bone metastases. Trial registration: POPSTAR, \u27Pilot Study of patients with Oligometastases from Prostate cancer treated with STereotactic Ablative Radiotherapy\u27, Universal Trial Number U1111-1140-7563, Registered 17th April 2013

    Associations with photoreceptor thickness measures in the UK Biobank.

    Get PDF
    Spectral-domain OCT (SD-OCT) provides high resolution images enabling identification of individual retinal layers. We included 32,923 participants aged 40-69 years old from UK Biobank. Questionnaires, physical examination, and eye examination including SD-OCT imaging were performed. SD OCT measured photoreceptor layer thickness includes photoreceptor layer thickness: inner nuclear layer-retinal pigment epithelium (INL-RPE) and the specific sublayers of the photoreceptor: inner nuclear layer-external limiting membrane (INL-ELM); external limiting membrane-inner segment outer segment (ELM-ISOS); and inner segment outer segment-retinal pigment epithelium (ISOS-RPE). In multivariate regression models, the total average INL-RPE was observed to be thinner in older aged, females, Black ethnicity, smokers, participants with higher systolic blood pressure, more negative refractive error, lower IOPcc and lower corneal hysteresis. The overall INL-ELM, ELM-ISOS and ISOS-RPE thickness was significantly associated with sex and race. Total average of INL-ELM thickness was additionally associated with age and refractive error, while ELM-ISOS was additionally associated with age, smoking status, SBP and refractive error; and ISOS-RPE was additionally associated with smoking status, IOPcc and corneal hysteresis. Hence, we found novel associations of ethnicity, smoking, systolic blood pressure, refraction, IOPcc and corneal hysteresis with photoreceptor thickness

    The Relationship Between Ambient Atmospheric Fine Particulate Matter (PM2.5) and Glaucoma in a Large Community Cohort.

    Get PDF
    Purpose: Glaucoma is more common in urban populations than in others. Ninety percent of the world's population are exposed to air pollution above World Health Organization (WHO) recommended limits. Few studies have examined the association between air pollution and glaucoma. Methods: Questionnaire data, ophthalmic measures, and ambient residential area air quality data for 111,370 UK Biobank participants were analyzed. Particulate matter with an aerodynamic diameter < 2.5 μm (PM2.5) was selected as the air quality exposure of interest. Eye measures included self-reported glaucoma, intraocular pressure (IOP), and average thickness of macular ganglion cell-inner plexiform layer (GCIPL) across nine Early Treatment Diabetic Retinopathy Study (ETDRS) retinal subfields as obtained from spectral-domain optical coherence tomography. We examined the associations of PM2.5 concentration with self-reported glaucoma, IOP, and GCIPL. Results: Participants resident in areas with higher PM2.5 concentration were more likely to report a diagnosis of glaucoma (odds ratio = 1.06, 95% confidence interval [CI] = 1.01-1.12, per interquartile range [IQR] increase P = 0.02). Higher PM2.5 concentration was also associated with thinner GCIPL (β = -0.56 μm, 95% CI = -0.63 to -0.49, per IQR increase, P = 1.2 × 10-53). A dose-response relationship was observed between higher levels of PM2.5 and thinner GCIPL (P < 0.001). There was no clinically relevant relationship between PM2.5 concentration and IOP. Conclusions: Greater exposure to PM2.5 is associated with both self-reported glaucoma and adverse structural characteristics of the disease. The absence of an association between PM2.5 and IOP suggests the relationship may occur through a non-pressure-dependent mechanism, possibly neurotoxic and/or vascular effects

    Retinal asymmetry in multiple sclerosis.

    Get PDF
    The diagnosis of multiple sclerosis is based on a combination of clinical and paraclinical tests. The potential contribution of retinal optical coherence tomography (OCT) has been recognized. We tested the feasibility of OCT measures of retinal asymmetry as a diagnostic test for multiple sclerosis at the community level. In this community-based study of 72 120 subjects, we examined the diagnostic potential of the inter-eye difference of inner retinal OCT data for multiple sclerosis using the UK Biobank data collected at 22 sites between 2007 and 2010. OCT reporting and quality control guidelines were followed. The inter-eye percentage difference (IEPD) and inter-eye absolute difference (IEAD) were calculated for the macular retinal nerve fibre layer (RNFL), ganglion cell inner plexiform layer (GCIPL) complex and ganglion cell complex. Area under the receiver operating characteristic curve (AUROC) comparisons were followed by univariate and multivariable comparisons accounting for a large range of diseases and co-morbidities. Cut-off levels were optimized by ROC and the Youden index. The prevalence of multiple sclerosis was 0.0023 [95% confidence interval (CI) 0.00229-0.00231]. Overall the discriminatory power of diagnosing multiple sclerosis with the IEPD AUROC curve (0.71, 95% CI 0.67-0.76) and IEAD (0.71, 95% CI 0.67-0.75) for the macular GCIPL complex were significantly higher if compared to the macular ganglion cell complex IEPD AUROC curve (0.64, 95% CI 0.59-0.69, P = 0.0017); IEAD AUROC curve (0.63, 95% CI 0.58-0.68, P  0.14) with narrow confidence intervals. In conclusion, the OCT macular GCIPL complex IEPD and IEAD may be considered as supportive measurements for multiple sclerosis diagnostic criteria in a young patient without relevant co-morbidity. The metric does not allow separation of multiple sclerosis from neuromyelitis optica. Retinal OCT imaging is accurate, rapid, non-invasive, widely available and may therefore help to reduce need for invasive and more costly procedures. To be viable, higher sensitivity and specificity levels are needed

    Association between polygenic risk score and risk of myopia

    Get PDF
    YesImportance: Myopia is a leading cause of untreatable visual impairment and is increasing in prevalence worldwide. Interventions for slowing childhood myopia progression have shown success in randomized clinical trials; hence, there is a need to identify which children would benefit most from treatment intervention. Objectives: To examine whether genetic information alone can identify children at risk of myopia development and whether including a child’s genetic predisposition to educational attainment is associated with improved genetic prediction of the risk of myopia. Design, Setting, and Participants: Meta-analysis of 3 genome-wide association studies (GWAS) including a total of 711 984 individuals. These were a published GWAS for educational attainment and 2 GWAS for refractive error in the UK Biobank, which is a multisite cohort study that recruited participants between January 2006 and October 2010. A polygenic risk score was applied in a population-based validation sample examined between September 1998 and September 2000 (Avon Longitudinal Study of Parents and Children [ALSPAC] mothers). Data analysis was performed from February 2018 to May 2019. Main Outcomes and Measures: The primary outcome was the area under the receiver operating characteristic curve (AUROC) in analyses for predicting myopia, using noncycloplegic autorefraction measurements for myopia severity levels of less than or equal to −0.75 diopter (D) (any), less than or equal to -3.00 D (moderate), or less than or equal to −5.00 D (high). The predictor variable was a polygenic risk score (PRS) derived from genome-wide association study data for refractive error (n = 95 619), age of onset of spectacle wear (n = 287 448), and educational attainment (n = 328 917). Results: A total of 383 067 adults aged 40 to 69 years from the UK Biobank were included in the new GWAS analyses. The PRS was evaluated in 1516 adults aged 24 to 51 years from the ALSPAC mothers cohort. The PRS had an AUROC of 0.67 (95% CI, 0.65-0.70) for myopia, 0.75 (95% CI, 0.70-0.79) for moderate myopia, and 0.73 (95% CI, 0.66-0.80) for high myopia. Inclusion in the PRS of information associated with genetic predisposition to educational attainment marginally improved the AUROC for myopia (AUROC, 0.674 vs 0.668; P = .02), but not those for moderate and high myopia. Individuals with a PRS in the top 10% were at 6.1-fold higher risk (95% CI, 3.4–10.9) of high myopia. Conclusions and Relevance: A personalized medicine approach may be feasible for detecting very young children at risk of myopia. However, accuracy must improve further to merit uptake in clinical practice; currently, cycloplegic autorefraction remains a better indicator of myopia risk (AUROC, 0.87).PhD studentship grant from the College of Optometrists (Drs Guggenheim and Williams; supporting Mr Mojarrad) entitled Genetic prediction of individuals at-risk for myopia development) and National Institute for Health Research (NIHR) Senior Research Fellowship award SRF-2015-08-005 (Dr Williams). The UK Medical Research Council and Wellcome grant 102215/2/13/2 and the University of Bristol provide core support for the Avon Longitudinal Study of Parents and Children (ALSPAC). A comprehensive list of grants funding is available on the ALSPAC website (http://www.bristol.ac.uk/alspac/external/documents/grant-acknowledgements.pdf). This research was conducted using the UK Biobank Resource (application 17351). The UK Biobank was established by the Wellcome Trust, the UK Medical Research Council, the Department for Health (London, England), the Scottish government (Edinburgh, Scotland), and the Northwest Regional Development Agency (Warrington, England). It also received funding from the Welsh Assembly Government (Cardiff, Wales), the British Heart Foundation, and Diabetes UK

    A new polygenic score for refractive error improves detection of children at risk of high myopia but not the prediction of those at risk of myopic macular degeneration

    Get PDF
    Background High myopia (HM), defined as a spherical equivalent refractive error (SER) ≤ −6.00 diopters (D), is a leading cause of sight impairment, through myopic macular degeneration (MMD). We aimed to derive an improved polygenic score (PGS) for predicting children at risk of HM and to test if a PGS is predictive of MMD after accounting for SER. Methods The PGS was derived from genome-wide association studies in participants of UK Biobank, CREAM Consortium, and Genetic Epidemiology Research on Adult Health and Aging. MMD severity was quantified by a deep learning algorithm. Prediction of HM was quantified as the area under the receiver operating curve (AUROC). Prediction of severe MMD was assessed by logistic regression. Findings In independent samples of European, African, South Asian and East Asian ancestry, the PGS explained 19% (95% confidence interval 17–21%), 2% (1–3%), 8% (7–10%) and 6% (3–9%) of the variation in SER, respectively. The AUROC for HM in these samples was 0.78 (0.75–0.81), 0.58 (0.53–0.64), 0.71 (0.69–0.74) and 0.67 (0.62–0.72), respectively. The PGS was not associated with the risk of MMD after accounting for SER: OR = 1.07 (0.92–1.24). Interpretation Performance of the PGS approached the level required for clinical utility in Europeans but not in other ancestries. A PGS for refractive error was not predictive of MMD risk once SER was accounted fo
    • …
    corecore