4 research outputs found

    VRLA battery state of health estimation based on charging time

    Get PDF
    Battery state of health (SoH) is an important parameter of the battery’s ability to store and deliver electrical energy. Various methods have been so far developed to calculate the battery SoH, such as through the calculation of battery impedance or battery capacity using Kalman Filter, Fuzzy theory, Probabilistic Neural Network, adaptive hybrid battery model, and Double Unscented Kalman Filtering (D-UKF) algorithm. This paper proposes an approach to estimate the value of battery SoH based on the charging time measurement. The results of observation and measurements showed that a new and used batteries would indicate different charging times. Unhealthy battery tends to have faster charging and discharging time. The undertaken analysis has been focused on finding out the relationship between the battery SoH and the charging time range. To validate the results of this proposed approach, the use of battery capacity method has been considered as comparison. It can be concluded that there is a strong correlation between the two discussed SoH estimation methods, confirming that the proposed method is feasible as an alternative SoH estimation method to the widely known battery capacity method. The correlation between the charging-disharging times of healthy and unhealthy batteries is very prospective to develop a battery charger in the future with a prime advantage of not requiring any sensor for the data acquisition

    Identifikasi Rentang Waktu Pengisian Terhadap State Of Health Baterai Valve-Regulated Lead Acid (VRLA)

    No full text
    State of Health baterai adalah suatu ukuran kemampuan sebuah baterai untuk menyimpan dan menyalurkan energi listrik. Nilai Estimasi State of Health pada sebuah baterai adalah suatu parameter penting dalam pemakaian baterai karena layak atau tidaknya baterai untuk tetap digunakan mengacu pada nilai estimasi tersebut. Berhubungan dengan semakin majunya perkembangan baterai Lead Acid hingga bertambahnya penggunaan baterai Valve-Regulated Lead Acid (VRLA) dalam sistem kelistrikan, maka pada penelitian ini akan dibahas keterkaitan antara State of Health baterai dengan rentang waktu pengisian, rancang bangun sebuah alat yang mampu menghitung nilai State of Health sebuah baterai VRLA dan menyimpan parameter tegangan, arus dan waktu selama proses pengisian. Data tersebut diolah di personal computer serta diidentifikasi keterkaitan antara rentang waktu pengisian dengan nilai State of Health suatu baterai. Metode yang dijadikan referensi nilai State of Health adalah metode perbandingan antara kapasitas akhir pengisian dan kapasitas nominal baterai tersebut. Hasil dari penelitian ini menunjukkan alat ini mampu membaca arus perubahan hingga 5 A dengan error pembacaan 2,828% serta sensor tegangan yang mampu membaca tegangan hingga 25 V dengan error pembacaan sebesar 0,257%. Hasil identifikasi menunjukkan metode perbandingan waktu pengisian baterai bekas terhadap baterai baru memiliki rentang error mulai dari 1,593% hingga 39,941% dengan persamaan trendline y = -0,5874x + 48,167 ( x = SOH). Batas error maksimal State of Health Baterai yang dapat diterima harus memiliki nilai dibawah 6% seperti yang ditunjukkan oleh Baterai Bekas 1 dan 2. Sedangkan untuk Baterai Bekas 3 dan 4 memiliki error melebihi 6% karena baterai yang memiliki nilai State of Health jauh di bawah 80% sudah dinyatakan sebagai baterai tidak layak pakai

    IDENTIFIKASI RENTANG WAKTU PENGISIAN TERHADAP STATE OF HEALTH BATERAI VALVE-REGULATED LEAD ACID (VRLA)

    No full text
    State of Health baterai adalah suatu ukuran kemampuan sebuah baterai untuk menyimpan dan menyalurkan energi listrik. Nilai Estimasi State of Health pada sebuah baterai adalah suatu parameter penting dalam pemakaian baterai karena layak atau tidaknya baterai untuk tetap digunakan mengacu pada nilai estimasi tersebut. Berhubungan dengan semakin majunya perkembangan baterai Lead-acid hingga bertambahnya penggunaan baterai Valve-Regulated Lead Acid (VRLA) dalam sistem kelistrikan, maka pada penelitian ini akan dibahas keterkaitan antara State of Health baterai dengan rentang waktu pengisian, rancang bangun sebuah alat yang mampu menghitung nilai State of Health sebuah baterai VRLA dan menyimpan parameter tegangan, arus dan waktu selama proses pengisian. Data tersebu diolah di personal computer serta diidentifikasi keterkaitan antara rentang waktu pengisian dengan nilai State of Health suatu baterai. Metode yang dijadikan referensi nilai State of Health adalah metode perbandingan antara kapasitas akhir pengisian dan kapasitas nominal baterai tersebut. Hasil dari penelitian ini menunjukkan alat ini mampu membaca arus perubahan hingga 5A dengan error pembacaan 2.828% serta sensor tegangan yang mampu membaca tegangan hingga 25 V dengan error pembacaan sebesar 0.257%. Hasil identifikasi menunjukkan metode perbandingan waktu pengisian memiliki rentang error mulai dari  1.593% hingga 39.941%. Kata kunci: State of Health, Valve-Regulated Lead Acid (VRLA), perbandingan kapasitas, waktu pengisian, testbench ABSTRACT The battery state of health (SOH) is a measure of the battery’s ability to store and deliver electrical energy. The Value of the State of Health on a battery is an important parameter in the use of the battery because the feasibleof  the battery to be used is based on the estimated value. Due to the increasing development of Lead-acid batteries to the increasing usage of Valve-Regulated Lead Acid (VRLA) batteries in electrical systems, this study will discuss the relationship between State of Health of the battery with the charging time range, design of a tool that can calculate the value State of Health a VRLA battery and store voltage, current and time parameters during charging process. The data is processed in personal computer and then identified the relationship between the charging time range with the value of the State of Health of a battery. The method which is used as a reference value State of Health is a method of comparison between the final charging capacity and the nominal capacity of the battery. The results of this study show that this tool is able to read the current changes up to 5A with error reading of 2828% and voltage sensors capable of reading voltages up to 25 V with error readings of 0.257%. The results of this identification shows that the method of comparison of charging time has an error ranging from 1.593% to 39.941%. Keywords: State of Health, Valve-Regulated Lead Acid (VRLA), capacity comparison, charging time, testbenc

    IDENTIFIKASI RENTANG WAKTU PENGISIAN TERHADAP STATE OF HEALTH BATERAI VALVE-REGULATED LEAD ACID (VRLA)

    No full text
    State of Health baterai adalah suatu ukuran kemampuan sebuah baterai untuk menyimpan dan menyalurkan energi listrik. Nilai Estimasi State of Health pada sebuah baterai adalah suatu parameter penting dalam pemakaian baterai karena layak atau tidaknya baterai untuk tetap digunakan mengacu pada nilai estimasi tersebut. Berhubungan dengan semakin majunya perkembangan baterai Lead-acid hingga bertambahnya penggunaan baterai Valve-Regulated Lead Acid (VRLA) dalam sistem kelistrikan, maka pada penelitian ini akan dibahas keterkaitan antara State of Health baterai dengan rentang waktu pengisian, rancang bangun sebuah alat yang mampu menghitung nilai State of Health sebuah baterai VRLA dan menyimpan parameter tegangan, arus dan waktu selama proses pengisian. Data tersebu diolah di personal computer serta diidentifikasi keterkaitan antara rentang waktu pengisian dengan nilai State of Health suatu baterai. Metode yang dijadikan referensi nilai State of Health adalah metode perbandingan antara kapasitas akhir pengisian dan kapasitas nominal baterai tersebut. Hasil dari penelitian ini menunjukkan alat ini mampu membaca arus perubahan hingga 5A dengan error pembacaan 2.828% serta sensor tegangan yang mampu membaca tegangan hingga 25 V dengan error pembacaan sebesar 0.257%. Hasil identifikasi menunjukkan metode perbandingan waktu pengisian memiliki rentang error mulai dari  1.593% hingga 39.941%. Kata kunci: State of Health, Valve-Regulated Lead Acid (VRLA), perbandingan kapasitas, waktu pengisian, testbench ABSTRACT The battery state of health (SOH) is a measure of the battery’s ability to store and deliver electrical energy. The Value of the State of Health on a battery is an important parameter in the use of the battery because the feasibleof  the battery to be used is based on the estimated value. Due to the increasing development of Lead-acid batteries to the increasing usage of Valve-Regulated Lead Acid (VRLA) batteries in electrical systems, this study will discuss the relationship between State of Health of the battery with the charging time range, design of a tool that can calculate the value State of Health a VRLA battery and store voltage, current and time parameters during charging process. The data is processed in personal computer and then identified the relationship between the charging time range with the value of the State of Health of a battery. The method which is used as a reference value State of Health is a method of comparison between the final charging capacity and the nominal capacity of the battery. The results of this study show that this tool is able to read the current changes up to 5A with error reading of 2828% and voltage sensors capable of reading voltages up to 25 V with error readings of 0.257%. The results of this identification shows that the method of comparison of charging time has an error ranging from 1.593% to 39.941%. Keywords: State of Health, Valve-Regulated Lead Acid (VRLA), capacity comparison, charging time, testbenc