277 research outputs found

    Stiffer optical tweezers through real-time feedback control

    Get PDF
    Using real-time re-programmable signal processing we connect acousto-optic steering and back-focal-plane interferometric position detection in optical tweezers to create a fast feedback controlled instrument. When trapping 3 µm latex beads in water we find that proportional-gain position-clamping increases the effective lateral trap stiffness ~13-fold. A theoretical power spectrum for bead fluctuations during position-clamped trapping is derived and agrees with the experimental data. The loop delay, ~19 µs in our experiment, limits the maximum achievable effective trap stiffness

    Transfer standard for traceable dynamic calibration of stroboscopic scanning white light interferometer

    Get PDF
    The reconstructed image of a moving sample always shows a distorted representation of reality. Therefore, one needs to calibrate, for example, out-of-plane nano-videos for quality control of nano-microelectromechanical systems (N-MEMS). Here we discuss how to calibrate and obtain confidence limits for stroboscopic scanning white light interferometry (SSWLI) data when there are differences in speed and amplitude across the field of view. Many N-MEMS devices rely on oscillating structures; consequently, one must calibrate movie recordings of these structures to have global standards and to allow inter-device comparison. We propose to use a quartz tuning fork driven off-resonance as a transfer standard. This approach allows a broad range of traceable frequencies and out-of-plane amplitudes to be introduced into selected parts of the field of view of the SSWLI device featuring similar optical surface properties to many N-MEMS devices without demanding an additional reference surface. (C) 2017 Optical Society of AmericaPeer reviewe

    Bayesian inference of physiologically meaningful parameters from body sway measurements

    Get PDF
    The control of the human body sway by the central nervous system, muscles, and conscious brain is of interest since body sway carries information about the physiological status of a person. Several models have been proposed to describe body sway in an upright standing position, however, due to the statistical intractability of the more realistic models, no formal parameter inference has previously been conducted and the expressive power of such models for real human subjects remains unknown. Using the latest advances in Bayesian statistical inference for intractable models, we fitted a nonlinear control model to posturographic measurements, and we showed that it can accurately predict the sway characteristics of both simulated and real subjects. Our method provides a full statistical characterization of the uncertainty related to all model parameters as quantified by posterior probability density functions, which is useful for comparisons across subjects and test settings. The ability to infer intractable control models from sensor data opens new possibilities for monitoring and predicting body status in health applications.Peer reviewe

    Single-molecule measurements of viral ssRNA packaging

    Get PDF
    Genome packaging of double-stranded RNA (dsRNA) phages has been widely studied using biochemical and molecular biology methods. We adapted the existing in vitro packaging system of one such phage for single-molecule experimentation. To our knowledge, this is the first attempt to study the details of viral RNA packaging using optical tweezers. Pseudomonas phage phi 6 is a dsRNA virus with a tripartite genome. Positive-sense (+) single-stranded RNA (ssRNA) genome precursors are packaged into a preformed procapsid (PC), where negative strands are synthesized. We present single-molecule measurements of the viral ssRNA packaging by the phi 6 PC. Our data show that packaging proceeds intermittently in slow and fast phases, which likely reflects differences in the unfolding of the RNA secondary structures of the ssRNA being packaged. Although the mean packaging velocity was relatively low (0.07-0.54 nm/sec), packaging could reach 4.62 nm/sec during the fast packaging phase.Peer reviewe

    Delivering Agents Locally into Articular Cartilage by Intense MHz Ultrasound

    Get PDF
    There is no cure for osteoarthritis. Current drug delivery relies on systemic delivery or injections into the joint. Because articular cartilage (AC) degeneration can be local and drug exposure outside the lesion can cause adverse effects, localized drug delivery could permit new drug treatment strategies. We investigated whether intense megahertz ultrasound (frequency: 1.138 MHz, peak positive pressure: 2.7 MPa, I-spta: 5 W/cm(2), beam width: 5.7 mm at -6 dB, duty cycle: 5%, pulse repetition frequency: 285 Hz, mechanical index: 1.1) can deliver agents into AC without damaging it. Using ultrasound, we delivered a drug surrogate down to a depth corresponding to 53% depth of the AC thickness without causing histologically detectable damage to the AC. This may be important because early osteoarthritis typically exhibits histopathologic changes in the superficial AC. In conclusion, we identify intense megahertz ultrasound as a technique that potentially enables localized non-destructive delivery of osteoarthritis drugs or drug carriers into articular cartilage. (E-mail: [email protected]) (C) 2015 World Federation for Ultrasound in Medicine & Biology.Peer reviewe

    Lyophilic matrix method for dissolution and release studies of nanoscale particles

    Get PDF
    We introduce a system with a lyophilic matrix to aid dissolution studies of powders and particulate systems. This lyophilic matrix method (LM method) is based on the ability to discriminate between non-dissolved particles and the dissolved species. In the LM method the test substance is embedded in a thin lyophilic core-shell matrix. This permits rapid contact with the dissolution medium while minimizing dispersion of non-dissolved particles without presenting a substantial diffusion barrier. The method produces realistic dissolution and release results for particulate systems, especially those featuring nanoscale particles. By minimizing method-induced effects on the dissolution profile of nanopowders, the LM method overcomes shortcomings associated with current dissolution tests. (C) 2017 Elsevier B.V. All rights reserved.Peer reviewe

    Practical realization of a sub-λ/2 acoustic jet

    Get PDF
    Studies in optics and acoustics have employed metamaterial lenses to achieve sub-wavelength localization, e.g. a recently introduced concept called 'acoustojet' which in simulations localizes acoustic energy to a spot smaller than lambda/2. However previous experimental results on the acoustojet have barely reached lambda/2-wide localization. Here we show, by simulations and experiments, that a sub-lambda/2 wide localization can be achieved by translating the concept of a photonic jet into the acoustic realm. We performed nano-to macroscale molecular dynamics (MD) and finite element method (FEM) simulations as well as macroscale experiments. We demonstrated that by choosing a suitable size cylindrical lens, and by selecting the speed-of-sound ratio between the lens material(s) and the surrounding medium, an acoustic jet ('acoustic sheet') is formed with a full width at half maximum (FWHM) less than lambda/2. The results show, that the acoustojet approach can be experimentally realized with easy-to-manufacture acoustic lenses at the macroscale. MD simulations demonstrate that the concept can be extended to coherent phonons at nanoscale. Finally, our FEM simulations identify some micrometer size structures that could be realized in practice. Our results may contribute to starting a new era of super resolution acoustic imaging: We foresee that jet generating constructs can be readily manufactured, since suitable material combinations can be found from nanoscale to macroscale. Tight focusing of mechanical energy is highly desirable in e.g. electronics, materials science, medicine, biosciences, and energy harvesting.Peer reviewe

    Effects of acoustic levitation on the development of zebrafish, Danio rerio, embryos

    Get PDF
    Acoustic levitation provides potential to characterize and manipulate material such as solid particles and fluid in a wall-less environment. While attempts to levitate small animals have been made, the biological effects of such levitation have been scarcely documented. Here, our goal was to explore if zebrafish embryos can be levitated (peak pressures at the pressure node and anti-node: 135 dB and 144 dB, respectively) with no effects on early development. We levitated the embryos (n = 94) at 2-14 hours post fertilization (hpf) for 1000 (n = 47) or 2000 seconds (n = 47). We compared the size and number of trunk neuromasts and otoliths in sonicated samples to controls (n = 94), and found no statistically significant differences (p > 0.05). While mortality rate was lower in the control group (22.3%) compared to that in the 1000 s (34.0%) and 2000 s (42.6%) levitation groups, the differences were statistically insignificant (p > 0.05). The results suggest that acoustic levitation for less than 2000 sec does not interfere with the development of zebrafish embryos, but may affect mortality rate. Acoustic levitation could potentially be used as a non-contacting wall-less platform for characterizing and manipulating vertebrae embryos without causing major adverse effects to their development.Peer reviewe
    corecore