220 research outputs found

    System identification of an enclosure with leakages using a probabilistic approach

    Get PDF
    This paper presents a model-based method for the system identification of a rectangular enclosure with an unknown number of air leakages subjected to uniform external noise, according to the probabilistic approach. The method aims to identify the number and corresponding locations and sizes of air leakages utilizing a set of measured, interior, sound pressure data in the frequency domain. System identification of an enclosure with an unknown number of air leakages is not trivial. Different classes of acoustic models are required to simulate an enclosure with different numbers of leakages. By following the traditional system of identification techniques, the "optimal" class of models is selected by minimizing the discrepancy between the measured and modeled interior sound pressure. By doing this, the most complicated model class (that is, the one with the highest number of uncertain parameters) will always be selected. Therefore, the traditional system identification techniques found in the literature to date cannot be employed to solve this problem. Our proposed system identification methodology relies on the Bayesian information criterion (BIC) to identify accurately the number of leakages in an enclosure. Unlike all deterministic system identification approaches, the proposed methodology aims to calculate the posterior (updated) probability density function (PDF) of leakage locations and sizes. Therefore, the uncertainties introduced by measurement noise and modeling error can be explicitly addressed. The coefficient of variable (COV) of uncertain parameters, which can be easily calculated from the PDF, provides valuable information about the reliability of the identification results. © 2008 Elsevier Ltd. All rights reserved.H. F. Lam, C. T. Ng, Y. Y. Lee and H. Y. Sunhttp://www.elsevier.com/wps/find/journaldescription.cws_home/622899/description#descriptio

    Wide-bandgap InAs/InGaP quantum-dot intermediate band solar cells

    Get PDF
    Current prototypes of quantum-dot intermediate band solar cells suffer from voltage reduction due to the existence of carrier thermal escape. An enlarged sub-bandgap EL would not only minimize this problem, but would also lead to a bandgap distribution that exploits more efficiently the solar spectrum. In this work we demonstrate InAs/InGaP QD-IBSC prototypes with the following bandgap distribution: EG = 1.88 eV, EH = 1.26 eV and EL > 0.4 eV. We have measured, for the first time in this material, both the interband and intraband transitions by means of photocurrent experiments. The activation energy of the carrier thermal escape in our devices has also been measured. It is found that its value, compared to InAs/GaAs-based prototypes, does not follow the increase in EL. The benefits of using thin AlGaAs barriers before and after the quantum-dot layers are analyzed

    Circulating Levels of Adipocyte and Epidermal Fatty Acid–Binding Proteins in Relation to Nephropathy Staging and Macrovascular Complications in Type 2 Diabetic Patients

    Get PDF
    OBJECTIVE—To investigate the relationships of serum adipocyte fatty acid–binding protein (A-FABP) and epidermal fatty acid–binding protein (E-FABP) with renal dysfunction and macrovascular complications in type 2 diabetic patients

    The aminobisphosphonate pamidronate controls influenza pathogenesis by expanding a γδ T cell population in humanized mice

    Get PDF
    As shown in humanized mice, a population of Vγ9Vδ2 T cells can reduce the severity and mortality of disease caused by infection with human and avian influenza viruses

    Effects of School Closures, 2008 Winter Influenza Season, Hong Kong

    Get PDF
    In winter 2008, kindergartens and primary schools in Hong Kong were closed for 2 weeks after media coverage indicated that 3 children had died, apparently from influenza. We examined prospective influenza surveillance data before, during, and after the closure. We did not find a substantial effect on community transmission

    Immunofluorescence Assay for Serologic Diagnosis of SARS

    Get PDF
    We evaluated a virus-infected cell-based indirect immunofluorescence assay for detecting anti–severe acute respiratory syndrome-associated coronavirus (SARS-CoV) immunoglobulin (Ig) G antibody. All confirmed SARS cases demonstrated seroconversion or fourfold rise in IgG antibody titer; no control was positive. Sensitivity and specificity of this assay were both 100%. Immunofluorescence assay can ascertain the status of SARS-CoV infection

    Surveillance of emerging drugs of abuse in Hong Kong: Validation of an analytical tool

    Get PDF
    © 2015, Hong Kong Academy of Medicine Press. All rights reserved. Objective: To validate a locally developed chromatography-based method to monitor emerging drugs of abuse whilst performing regular drug testing in abusers. Design: Cross-sectional study. Setting: Eleven regional hospitals, seven social service units, and a tertiary level clinical toxicology laboratory in Hong Kong. Participants: A total of 972 drug abusers and high-risk individuals were recruited from acute, rehabilitation, and high-risk settings between 1 November 2011 and 31 July 2013. A subset of the participants was of South Asian ethnicity. In total, 2000 urine or hair specimens were collected. Main outcome measures: Proof of concept that surveillance of emerging drugs of abuse can be performed whilst conducting routine drug of abuse testing in patients. Results: The method was successfully applied to 2000 samples with three emerging drugs of abuse detected in five samples: PMMA (paramethoxymethamphetamine), TFMPP [1-(3-trifluoromethylphenyl)piperazine], and methcathinone. The method also detected conventional drugs of abuse, with codeine, methadone, heroin, methamphetamine, and ketamine being the most frequently detected drugs. Other findings included the observation that South Asians had significantly higher rates of using opiates such as heroin, methadone, and codeine; and that ketamine and cocaine had significantly higher detection rates in acute subjects compared with the rehabilitation population. Conclusions: This locally developed analytical method is a valid tool for simultaneous surveillance of emerging drugs of abuse and routine drug monitoring of patients at minimal additional cost and effort. Continued, proactive surveillance and early identification of emerging drugs will facilitate prompt clinical, social, and legislative management.Link_to_subscribed_fulltex

    Genetic variants for head size share genes and pathways with cancer

    Get PDF
    The size of the human head is highly heritable, but genetic drivers of its variation within the general population remain unmapped. We perform a genome-wide association study on head size (N = 80,890) and identify 67 genetic loci, of which 50 are novel. Neuroimaging studies show that 17 variants affect specific brain areas, but most have widespread effects. Gene set enrichment is observed for various cancers and the p53, Wnt, and ErbB signaling pathways. Genes harboring lead variants are enriched for macrocephaly syndrome genes (37-fold) and high-fidelity cancer genes (9-fold), which is not seen for human height variants. Head size variants are also near genes preferentially expressed in intermediate progenitor cells, neural cells linked to evolutionary brain expansion. Our results indicate that genes regulating early brain and cranial growth incline to neoplasia later in life, irrespective of height. This warrants investigation of clinical implications of the link between head size and cancer.</p

    Search for gravitational waves from Scorpius X-1 in the second Advanced LIGO observing run with an improved hidden Markov model

    Get PDF
    We present results from a semicoherent search for continuous gravitational waves from the low-mass x-ray binary Scorpius X-1, using a hidden Markov model (HMM) to track spin wandering. This search improves on previous HMM-based searches of LIGO data by using an improved frequency domain matched filter, the J-statistic, and by analyzing data from Advanced LIGO's second observing run. In the frequency range searched, from 60 to 650 Hz, we find no evidence of gravitational radiation. At 194.6 Hz, the most sensitive search frequency, we report an upper limit on gravitational wave strain (at 95% confidence) of h095%=3.47×10-25 when marginalizing over source inclination angle. This is the most sensitive search for Scorpius X-1, to date, that is specifically designed to be robust in the presence of spin wandering. © 2019 American Physical Society
    corecore