6,168 research outputs found

    Connector for vacuum-jacketed lines cuts tubing system cost

    Get PDF
    A low-cost fitting, fabricated from standard connectors, is used for disconnecting flow lines in cryogenic systems. Utilizing vacuum-jacketed lines made from two sizes of tubing welded at the ends, the connectors are stronger and setup time is reduced

    Modification and improvements to cooled blades Patent

    Get PDF
    Modification and improvement of turbine blades for maximum cooling efficienc

    Full-field pulsed magneto-photoelasticity – Experimental Implementation

    No full text
    This paper contains a description of the experimental procedure employed when using a pulsed-magneto-polariscope (PMP) and some initial full-field through-thickness measurements of the stress distribution present in samples containing 3D stresses. The instrument uses the theory of magneto-photoelasticity (MPE), which is an experimental stress analysis technique that involves the application of a magnetic field to a birefringent model within a polariscope. MPE was developed for through-thickness stress measurement where the integrated through-thickness birefringent measurement disguises the actual stress distribution. MPE is mainly used in toughened glass where the through-thickness distribution can reduce its overall strength and so its determination is important. To date MPE has been a single-point 2D through-thickness measurement and the analysis time is prohibitive for the investigation of an area which may contain high localised stresses. The pulsed-magneto-polariscope (PMP) has been designed to enable the application of full-field 3D MPE [ ]. Using a proof-of concept PMP several experimental measurements were made, these were promising and demonstrate the potential of the new instrument. Further development of this technique presents several exciting possibilities including a tool for the measurement of the distribution of principal stress difference seen in a general 3D model

    Composite, vacuum-jacketed tubing replaces bellows in cryogenic systems

    Get PDF
    For reliability control of high pressure cryogenic systems, one or more 90 degree elbow expansion devices are substituted for the metal bellows normally used. The device consists of a conducting tube inside a support tube, with the space between the tubes evacuated for insulation

    Fencing Laws in Missouri-Restraining Animals

    Get PDF

    Driver behaviour at roadworks

    Get PDF
    corecore