62 research outputs found

    Asprosin exerts pro-inflammatory effects in THP-1 macrophages mediated via the Toll-like receptor 4 (TLR4) pathway

    Get PDF
    Adipose tissue is a dynamic endocrine organ, secreting a plethora of adipokines which play a key role in regulating metabolic homeostasis and other physiological processes. An altered adipokine secretion profile from adipose tissue depots has been associated with obesity and related cardio-metabolic diseases. Asprosin is a recently described adipokine that is released in response to fasting and can elicit orexigenic and glucogenic effects. Circulating asprosin levels are elevated in a number of cardio-metabolic diseases, including obesity and type 2 diabetes. In vitro studies have reported pro-inflammatory effects of asprosin in a variety of tissues. The present study aimed to further elucidate the role of asprosin in inflammation by exploring its potential effect(s) in THP-1 macrophages. THP-1 monocytes were differentiated to macrophages by 48 h treatment with dihydroxyvitamin D3. Macrophages were treated with 100 nM recombinant human asprosin, 100 ng/mL lipopolysaccharide (LPS), and 10 μM caffeic acid phenethyl ester (CAPE; an inhibitor of NFκB activation) or 1 µM TAK-242 (a Toll-like receptor 4, TLR4, inhibitor). The expression and secretion of pertinent pro-inflammatory mediators were measured by qPCR, Western blot, ELISA and Bioplex. Asprosin stimulation significantly upregulated the expression and secretion of the pro-inflammatory cytokines: tumour necrosis factor α (TNFα), interleukin-1β (IL-1β), IL-8 and IL-12 in vitro. This pro-inflammatory response in THP-1 macrophages was partly attenuated by the treatments with CAPE and was significantly inhibited by TAK-242 treatment. Asprosin-induced inflammation is significantly counteracted by TLR4 inhibition in THP-1 macrophages, suggesting that asprosin exerts its pro-inflammatory effects, at least in part, via the TLR4 signalling pathway

    Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

    Get PDF
    This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes

    A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings

    Get PDF
    BackgroundA composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data.MethodsWe assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low-glucose and low-glucose hypoglycemia; very high-glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation.ResultsThe analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals.ConclusionThe GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments

    Benchmarking Hydrogen Evolving Reaction and Oxygen Evolving Reaction Electrocatalysts for Solar Water Splitting Devices

    Full text link

    Design, synthesis and evaluation of a series of acyclic fleximer nucleoside analogues with anti-coronavirus activity

    No full text
    A series of doubly flexible nucleoside analogues were designed based on the acyclic sugar scaffold of acyclovir and the flex-base moiety found in the fleximers. The target compounds were evaluated for their antiviral potential and found to inhibit several coronaviruses. Significantly, compound 2 displayed selective antiviral activity (CC(50) > 3x EC(50)) towards human coronavirus (HCoV)-NL63 and Middle East respiratory syndrome-coronavirus, but not severe acute respiratory syndrome-coronavirus. In the case of HCoV-NL63 the activity was highly promising with an EC(50) < 10 μM and a CC(50) > 100 μM. As such, these doubly flexible nucleoside analogues are viewed as a novel new class of drug candidates with potential for potent inhibition of coronaviruses

    Design, synthesis and evaluation of a series of acyclic fleximer nucleoside analogues with anti-coronavirus activity

    No full text
    A series of doubly flexible nucleoside analogues were designed based on the acyclic sugar scaffold of acyclovir and the flex-base moiety found in the fleximers. The target compounds were evaluated for their antiviral potential and found to inhibit several coronaviruses. Significantly, compound 2 displayed selective antiviral activity (CC50 >3× EC50) towards human coronavirus (HCoV)-NL63 and Middle East respiratory syndrome-coronavirus, but not severe acute respiratory syndrome-coronavirus. In the case of HCoV-NL63 the activity was highly promising with an EC50 100μM. As such, these doubly flexible nucleoside analogues are viewed as a novel new class of drug candidates with potential for potent inhibition of coronaviruses.publisher: Elsevier articletitle: Design, synthesis and evaluation of a series of acyclic fleximer nucleoside analogues with anti-coronavirus activity journaltitle: Bioorganic & Medicinal Chemistry Letters articlelink: http://dx.doi.org/10.1016/j.bmcl.2015.05.039 content_type: article copyright: Copyright © 2015 Elsevier Ltd. All rights reserved.status: publishe

    PRIDE Statement on the Need for a Moratorium on the CMS Plan to Cite Hospitals for Performing Point- of-Care Capillary Blood Glucose Monitoring on Critically Ill Patients

    No full text
    Objective: A writing committee of the Planning Research in Inpatient Diabetes (PRIDE) group has written this consensus article on behalf of the group in response to a specific request for input from the Centers for Medicare and Medicaid Services (CMS). The purpose of this article is to respond to the March 13, 2015 statement from that agency regarding plans to enforce prohibition of the off-label use of point of care (POC) capillary blood glucose monitor (BGM) testing in most critically ill patients. The article discusses: 1) how POC BGM testing is currently regulated; 2) how POC BGM testing is currently used in the United States; and 3) how POC BGM testing can be safely and effectively regulated in the future through cooperation between the clinician, laboratory, regulatory, industry, and patient communities. Participants: Nine members of PRIDE volunteered to write the statement on behalf of the entire group. Evidence: Descriptions of current medical practice for critically ill patients were derived from the experience of the authors. Descriptions of the performance of various methods for measuring glucose levels for intensive insulin therapy came from a literature review. Consensus Process: Eleven questions were developed by the PRIDE writing group. After extensive electronic and telephone discussion, the article was written and reviewed by all nine authors and then reviewed by two outside experts in the care of critically ill patients. All suggestions by the authors and the outside experts were incorporated. Conclusions: Although the CMS is attempting to protect patients with abnormal glycemic control from harm due to inaccurate POC fingerstick capillary BGM testing, their plan will result in more harm than good. A moratorium on enforcement of the prohibition of off-label use of POC capillary BGM testing is needed. (J Clin Endocrinol Metab 100: 0000 -0000, 2015

    PRIDE Statement on the Need for a Moratorium on the CMS Plan to Cite Hospitals for Performing Point- of-Care Capillary Blood Glucose Monitoring on Critically Ill Patients

    No full text
    Objective: A writing committee of the Planning Research in Inpatient Diabetes (PRIDE) group has written this consensus article on behalf of the group in response to a specific request for input from the Centers for Medicare and Medicaid Services (CMS). The purpose of this article is to respond to the March 13, 2015 statement from that agency regarding plans to enforce prohibition of the off-label use of point of care (POC) capillary blood glucose monitor (BGM) testing in most critically ill patients. The article discusses: 1) how POC BGM testing is currently regulated; 2) how POC BGM testing is currently used in the United States; and 3) how POC BGM testing can be safely and effectively regulated in the future through cooperation between the clinician, laboratory, regulatory, industry, and patient communities. Participants: Nine members of PRIDE volunteered to write the statement on behalf of the entire group. Evidence: Descriptions of current medical practice for critically ill patients were derived from the experience of the authors. Descriptions of the performance of various methods for measuring glucose levels for intensive insulin therapy came from a literature review. Consensus Process: Eleven questions were developed by the PRIDE writing group. After extensive electronic and telephone discussion, the article was written and reviewed by all nine authors and then reviewed by two outside experts in the care of critically ill patients. All suggestions by the authors and the outside experts were incorporated. Conclusions: Although the CMS is attempting to protect patients with abnormal glycemic control from harm due to inaccurate POC fingerstick capillary BGM testing, their plan will result in more harm than good. A moratorium on enforcement of the prohibition of off-label use of POC capillary BGM testing is needed. (J Clin Endocrinol Metab 100: 0000 -0000, 2015
    corecore