185 research outputs found

    Optimaliseren van biotoetsen voor het meten van bodemweerbaarheid van Verticillium dahliae en Pythium spp.

    Get PDF
    In de grondgebonden teelten is de bestrijding van ziektes een lastig probleem doordat steeds meer chemische bestrijdingsmiddelen niet meer gebruikt mogen worden. Daarnaast zijn milieuvriendelijke oplossingen belangrijk. De competentie van de bodem om ziekten en plagen te onderdrukken wordt hierdoor steeds interessanter. De biotoets is op dit moment de enige manier om bodemweerbaarheid te mete

    An optical method to determine the thermodynamics of hydrogen absorption and desorption in metals

    Get PDF
    Hydrogenography, an optical high-throughput combinatorial technique to find hydrogen storage materials, has so far been applied only to materials undergoing a metal-to-semiconductor transition during hydrogenation. We show here that this technique works equally well for metallic hydrides. Additionally, we find that the thermodynamic data obtained optically on thin Pd-H films agree very well with Pd-H bulk data. This confirms that hydrogenography is a valuable general method to determine the relevant parameters for hydrogen storage in metal hydrides. © 2007 American Institute of Physics

    Een plek om vreemden te herkennen

    Get PDF
    Criminal Justice: Legitimacy, accountability, and effectivit

    Fiber-top cantilever:a new generation of micromachined sensors for multipurpose applications

    Get PDF
    Fiber-top cantilevers are new monolithic devices obtained by carving a cantilever out of the edge of a single-mode optical fiber. Here we report evidences of their potential impact as sensing devices for multipurpose applications

    Advances in Fecal Tests for Colorectal Cancer Screening

    Get PDF
    textabstractColorectal cancer (CRC) forms an important public health problem, especially in developed countries. CRC screening tests can be used to identify asymptomatic individuals with CRC precursors and (early) cancer. Removal of these lesions reduces CRC incidence and prevents CRC-related mortality. There are a range of screening tests available, each with advantages and disadvantages. Stool screening tests can broadly be divided into fecal occult blood tests (FOBTs) and molecular biomarker test, such as DNA/RNA marker tests, protein markers, and fecal microbiome marker tests. Guaiac fecal occult blood tests (gFOBT) have been demonstrated in large randomized screening trials to reduce CRC mortality. Fecal immunochemical tests (FIT) have superior adherence, usability, and accuracy as compared to gFOBT. Advantage of the use of quantitative FITs in CRC screening programs is the cut-off level that can be adjusted. Molecular biomarker DNA tests have shown to detect significantly more cancers than FIT. By combining biomarker DNA tests with FIT, sensitivity for advanced adenomas can be increased significantly. However, it has lower specificity thus demands more colonoscopy resources, is more cumbersome, and costly. The adherence has not been assessed in population screening trials. For these reasons, FIT is therefore at present regarded as the preferred method of non-invasive CRC screening. This chapter will review the current status of fecal test-based CRC screening

    Mg/Ti multilayers: structural, optical and hydrogen absorption properties

    Get PDF
    Mg-Ti alloys have uncommon optical and hydrogen absorbing properties, originating from a "spinodal-like" microstructure with a small degree of chemical short-range order in the atoms distribution. In the present study we artificially engineer short-range order by depositing Pd-capped Mg/Ti multilayers with different periodicities and characterize them both structurally and optically. Notwithstanding the large lattice parameter mismatch between Mg and Ti, the as-deposited metallic multilayers show good structural coherence. Upon exposure to H2 gas a two-step hydrogenation process occurs, with the Ti layers forming the hydride before Mg. From in-situ measurements of the bilayer thickness L at different hydrogen pressures, we observe large out-of-plane expansions of the Mg and Ti layers upon hydrogenation, indicating strong plastic deformations in the films and a consequent shortening of the coherence length. Upon unloading at room temperature in air, hydrogen atoms remain trapped in the Ti layers due to kinetic constraints. Such loading/unloading sequence can be explained in terms of the different thermodynamic properties of hydrogen in Mg and Ti, as shown by diffusion calculations on a model multilayered systems. Absorption isotherms measured by hydrogenography can be interpreted as a result of the elastic clamping arising from strongly bonded Mg/Pd and broken Mg/Ti interfaces

    Mg-Ti-H thin films for smart solar collectors

    Get PDF
    Mg-Ti-H thin films are found to have very attractive optical properties: they absorb 87% of the solar radiation in the hydrogenated state and only 32% in the metallic state. Furthermore, in the absorbing state Mg-Ti-H has a low emissivity; at 400 K only 10% of blackbody radiation is emitted. The transition between both optical states is fast, robust, and reversible. The sum of these properties highlights the applicability of such materials as switchable smart coatings in solar collector

    Structural and optical properties of Mg<sub>x</sub>Al<sub>1-x</sub>H<sub>y</sub> gradient thin films: a combinatorial approach

    Get PDF
    The structural, optical and dc electrical properties of MgxAl1-x (0.2≤x≤0.9) gradient thin films covered with Pd/Mg are investigated before and after exposure to hydrogen. We use hydrogenography, a novel high-throughput optical technique, to map simultaneously all the hydride forming compositions and the kinetics thereof in the gradient thin film. Metallic Mg in the MgxAl1-x layer undergoes a metal-to-semiconductor transition and MgH₂ is formed for all Mg fractions x investigated. The presence of an amorphous Mg-Al phase in the thin film phase diagram enhances strongly the kinetics of hydrogenation. In the Al-rich part of the film, a complex H-induced segregation of MgH₂ and Al occurs. This uncommon large-scale segregation is evidenced by metal and hydrogen profiling using Rutherford backscattering spectrometry and resonant nuclear analysis based on the reaction ¹H(¹⁵N,αγ)¹²C. Besides MgH₂, an additional semiconducting phase is found by electrical conductivity measurements around an atomic [Al]/[Mg] ratio of 2 (x=0.33). This suggests that the film is partially transformed into Mg(AlH₄)₂ at around this composition

    Cost-effectiveness of problem-solving treatment in comparison with usual care for primary care patients with menthal health problems: a randomized trial

    Get PDF
    BACKGROUND: Mental health problems are common and are associated with increased disability and health care costs. Problem-Solving Treatment (PST) delivered to these patients by nurses in primary care might be efficient. The aim of this study was to evaluate the cost-effectiveness of PST by mental health nurses compared with usual care (UC) by the general practitioner for primary care patients with mental health problems. METHODS: An economic evaluation from a societal perspective was performed alongside a randomized clinical trial. Patients with a positive General Health Questionnaire score (score ≥ 4) and who visited their general practitioner at least three times during the past 6 months were eligible. Outcome measures were improvement on the Hospital Anxiety and Depression Scale and QALYs based on the EQ-5D. Resource use was measured using a validated questionnaire. Missing cost and effect data were imputed using multiple imputation techniques. Bootstrapping was used to analyze costs and cost-effectiveness of PST compared with UC. RESULTS: There were no statistically significant differences in clinical outcomes at 9 months. Mean total costs were €4795 in the PST group and €6857 in the UC group. Costs were not statistically significantly different between the two groups (95% CI -4698;359). The cost-effectiveness analysis showed that PST was cost-effective in comparison with UC. Sensitivity analyses confirmed these findings. CONCLUSIONS: PST delivered by nurses seems cost-effective in comparison with UC. However, these results should be interpreted with caution, since the difference in total costs was mainly caused by 3 outliers with extremely high indirect costs in the UC group. TRIAL REGISTRATION: Nederlands Trial Register ISRCTN5102101
    corecore