196 research outputs found

    Seasonal variation of the transport of black carbon aerosol from the Asian continent to the Arctic during the ARCTAS aircraft campaign

    Get PDF
    Extensive measurements of black carbon (BC) aerosol were conducted in and near the North American Arctic during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) aircraft campaign in April and June-July 2008. We identify the pathways and mechanisms of transport of BC to the Arctic from the Asian continent using these data. The concentration, transport efficiency, and measured altitude of BC over the North American Arctic were highly dependent on season and origin of air parcels, e.g., biomass burning (BB) in Russia (Russian BB) and anthropogenic (AN) in East Asia (Asian AN). Russian BB air was mainly measured in the middle troposphere and caused maximum BC concentrations at this altitude in spring. The median BC concentration and transport efficiency of the Russian BB air were 270 ng m -3 (at STP) and 80% in spring and 20 ng m-3 and 4% in summer, respectively. Asian AN air was measured most frequently in the upper troposphere, with median values of 20 ng m-3 and 13% in spring and 5 ng m-3 and 0.8% in summer. These distinct differences are explained by differences in the transport mechanisms and accumulated precipitation along trajectories (APT), which is a measure of wet removal processes during transport. The transport of Russian BB air to the Arctic was nearly isentropic with slow ascent (low APT), while Asian AN air underwent strong uplift associated with warm conveyor belts (high APT). The APT values in summer were much larger than those in spring due to the increase in humidity in summer. These results show that the impact of BC emitted from AN sources in East Asia on the Arctic was very limited in both spring and summer. The BB emissions in Russia in spring are demonstrated to be the most important sources of BC transported to the North American Arctic. Copyright 2011 by the American Geophysical Union

    Accumulation-mode aerosol number concentrations in the Arctic during the ARCTAS aircraft campaign: Long-range transport of polluted and clean air from the Asian continent

    Get PDF
    We evaluate the impact of transport from midlatitudes on aerosol number concentrations in the accumulation mode (light-scattering particles (LSP) with diameters >180 nm) in the Arctic during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) campaign. We focus on transport from the Asian continent. We find marked contrasts in the number concentration (NLSP), transport efficiency (TE N-LSP, the fraction transported from sources to the Arctic), size distribution, and the chemical composition of aerosols between air parcels from anthropogenic sources in East Asia (Asian AN) and biomass burning sources in Russia and Kazakhstan (Russian BB). Asian AN air had lower NLSP and TEN-LSP (25 cm-3 and 18% in spring and 6.2 cm-3 and 3.0% in summer) than Russian BB air (280 cm-3 and 97% in spring and 36 cm-3 and 7.6% in summer) due to more efficient wet scavenging during transport from East Asia. Russian BB in this spring is the most important source of accumulation-mode aerosols over the Arctic, and BB emissions are found to be the primary source of aerosols within all the data in spring during ARCTAS. On the other hand, the contribution of Asian AN transport had a negligible effect on the accumulation-mode aerosol number concentration in the Arctic during ARCTAS. Compared with background air, NLSP was 2.3-4.7 times greater for Russian BB air but 2.4-2.6 times less for Asian AN air in both spring and summer. This result shows that the transport of Asian AN air decreases aerosol number concentrations in the Arctic, despite the large emissions of aerosols in East Asia. The very low aerosol number concentrations in Asian AN air were caused by wet removal during vertical transport in association with warm conveyor belts (WCBs). Therefore, this cleansing effect will be prominent for air transported via WCBs from other midlatitude regions and seasons. The inflow of clean midlatitude air can potentially have an important impact on accumulation-mode aerosol number concentrations in the Arctic. Copyright 2011 by the American Geophysical Union

    Analysis of factor interactions with RNA polymerase II elongation complexes using a new electrophoretic mobility shift assay

    Get PDF
    The elongation phase of transcription by RNA polymerase II (RNAP II) is controlled by a carefully orchestrated series of interactions with both negative and positive factors. However, due to the limitations of current methods and techniques, not much is known about whether and how these proteins physically associate with the engaged polymerases. To gain insight into the detailed mechanisms involved, we established an experimental system for analyzing direct factor interactions to RNAP II elongation complexes on native gels, namely elongation complex electrophoretic mobility shift assay (EC-EMSA). This new assay effectively allowed detection of interactions of TFIIF, TTF2, TFIIS, DSIF and P-TEFb with elongation complexes generated from a natural promoter using an immobilized template. As an application of this assay system, we characterized the association of transcription elongation factor DSIF with RNAP II elongation complexes and discovered that the nascent transcript facilitated recruitment of DSIF. Examples of how the system can be manipulated to address different questions are provided. EC-EMSA should be useful for further investigation of factor interactions with RNAP II elongation complexes

    Effects of microperfusion in hepatic diffusion weighted imaging

    Get PDF
    Clinical hepatic diffusion weighted imaging (DWI) generally relies on mono-exponential diffusion. The aim was to demonstrate that mono-exponential diffusion in the liver is contaminated by microperfusion and that the bi-exponential model is required. Nineteen fasting healthy volunteers were examined with DWI (seven b-values) using fat suppression and respiratory triggering (1.5 T). Five different regions in the liver were analysed regarding the mono-exponentially fitted apparent diffusion coefficient (ADC), and the bi-exponential model: molecular diffusion (D (slow) ) microperfusion (D (fast) ) and the respective fractions (f (slow/fast)). Data were compared using ANOVA and Kruskal-Wallis tests. Simulations were performed by repeating our data analyses, using just the DWI series acquired with b-values approximating those of previous studies. Median mono-exponentially fitted ADCs varied significantly (P <0.001) between 1.107 and 1.423 x 10(-3) mm(2)/s for the five regions. Bi-exponential fitted D-slow varied between 0.923 and 1.062 x 10(-3) mm(2)/s without significant differences (P = 0.140). D (fast) varied significantly, between 17.8 and 46.8 x 10(-3) mm(2)/s (P <0.001). F-tests showed that the diffusion data fitted the bi-exponential model significantly better than the mono-exponential model (F > 21.4, P <0.010). These results were confirmed by the simulations. ADCs of normal liver tissue are significantly dependent on the measurement location because of substantial microperfusion contamination; therefore the bi-exponential model should be used. Diffusion weighted MR imaging helps clinicians to differentiate tumours by diffusion properties Fast moving water molecules experience microperfusion, slow molecules diffusion Hepatic diffusion should be measured by bi-exponential models to avoid microperfusion contamination Mono-exponential models are contaminated with microperfusion, resulting in apparent regional diffusion differences Bi-exponential models are necessary to measure diffusion and microperfusion in the liver

    Prevalence of primary biliary cirrhosis in adults referring hospital for annual health check-up in Southern China

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Primary biliary cirrhosis (PBC) is an autoimmune liver disease characterized by the presence of anti-mitocondrial autoantibodies (AMA) which has an essential role also for diagnosis. In addition, also some anti-nuclear antibodies (ANA) have been shown to be highly specific PBC. The purpose of this study was to assess the prevalence of PBC among the adults referring hospital for annual health check-up in Southern China by screening sera for PBC-specific autoantibodies.</p> <p>Methods</p> <p>AMA and ANA were screened in 8,126 adults (mean age 44 ± 15 years, 48% females) by indirect immunofluorenscence (IIF). Positive sera were tested by ELISA/immunoblotting for AMA-M2, anti-sp100 and anti-gp210. A diagnosis of PBC was re-assessed six months after the initial testing.</p> <p>Results</p> <p>Out of 8,126 individuals 35 were positive for AMA and 79 positive for ANA. Nineteen, 4, and 3 of the subjects positive for AMA and/or ANA showed reactivity for AMA-M2, anti-sp100 or gp210, respectively, further tested with ELISA/immunoblotting. Fourteen in the 39 individuals positive for AMA at IIF, AMA-M2, anti-gp210, or anti-sp100 had abnormal cholestatic liver functional indices. One definite and 3 probable PBC diagnosis could be made in 4 cases including 3 females and 1 male after half a year.</p> <p>Conclusions</p> <p>We found a point prevalence rate of PBC among Southern Chinese adults attending for yearly health check-up of 492 cases per million (95% CI, 128 to 1,093) and 1,558 cases per million (95% CI, 294 to 3,815) for women over 40, a finding similar to prevalence reported in other geographical areas.</p

    Evaluation of Black Carbon Estimations in Global Aerosol Models

    Get PDF
    We evaluate black carbon (BC) model predictions from the AeroCom model intercomparison project by considering the diversity among year 2000 model simulations and comparing model predictions with available measurements. These 5 model-measurement intercomparisons include BC surface and aircraft concentrations, aerosol absorption optical depth (AAOD) from AERONET and Ozone Monitoring Instrument (OMI) retrievals and BC column estimations based on AERONET. In regions other than Asia, most models are biased high compared to surface concentration measurements. However compared with (column) AAOD or BC burden retreivals, the models 10 are generally biased low. The average ratio of model to retrieved AAOD is less than 0.7 in South American and 0.6 in African biomass burning regions; both of these regions lack surface concentration measurements. In Asia the average model to observed ratio is 0.6 for AAOD and 0.5 for BC surface concentrations. Compared with aircraft measurements over the Americas at latitudes between 0 and 50 N, the average model is a 15 factor of 10 larger than observed, and most models exceed the measured BC standard deviation in the mid to upper troposphere. At higher latitudes the average model to aircraft BC is 0.6 and underestimates the observed BC loading in the lower and middle troposphere associated with springtime Arctic haze. Low model bias for AAOD but overestimation of surface and upper atmospheric BC concentrations at lower latitudes 20 suggests that most models are underestimating BC absorption and should improve estimates for refractive index, particle size, and optical effects of BC coating. Retrieval uncertainties and/or differences with model diagnostic treatment may also contribute to the model-measurement disparity. Largest AeroCom model diversity occurred in northern Eurasia and the remote Arctic, regions influenced by anthropogenic sources. 25 Changing emissions, aging, removal, or optical properties within a single model generated a smaller change in model predictions than the range represented by the full set of AeroCom models. Upper tropospheric concentrations of BC mass from the aircraft measurements are suggested to provide a unique new benchmark to test scavenging and vertical dispersion of BC in global models.JRC.H.2-Climate chang
    corecore