1,694 research outputs found
Comparison of four mobility particle sizers with different time resolution for stationary exposure measurements
Performance and Carcass Traits of Market Beef Cattle Supplemented Self-Fed Byproducts on Pasture: Final Report
Over a two year period (2007 and 2008), 162 head of beef steers were finished with self-fed byproducts on cool season grass pastures. Yearling steers were continuously grazed at the Neely-Kinyon Farm in southwest Iowa on cool season grasses that were predominantly fescue at a stocking density of 2.25 head/acre. Half of the cattle were implanted (with Synovex®-S) or half were not. Cattle received a diet of either soyhulls-dried distillers grain with solubles (DDGS) or ground corn-dried distillers grains with solubles that was offered through self-feeders. The rations were mixed at a 1:1 ratio with a mineral balancer added which included Rumensin®.
Live cattle performance and carcass traits were not affected by diet. Implanted cattle outgained non-implanted over the entire finishing period (3.52 lbs/d vs. 3.17 lbs/d). This led to implanted cattle coming off test heavier (1324 lbs vs. 1277 lbs) and railing with heavier carcasses (826 lbs vs. 800 lbs). Ribeye areas were greater (13.1 in2 vs. 12.7 in2) for implanted cattle; which was probably due to the heavier carcass weights. Non-implanted cattle had superior quality grades (55% vs. 40%) of low choice or better. Fatty acid profiles from the first year were analyzed and showed that raw beef samples from cattle on the soyhulls diet had significantly higher C18:2
In conclusion, pasture rearing cattle, when given access to self-fed by-products, provides for excellent performance on both live performance and carcass traits. Some considerations should be made by the feeder in regards to time of year when marketing cattle and the cattle’s genetics. This system is an alternative to high-grain conventional beef finishing production in feedlots
Noise propagation issues in Belle II pixel detector power cable
The vertex detector used in the upgrade of High-Energy physics experiment Belle II includes DEPFET pixel detector (PXD) technology. In this complex topology the power supply units and the front-end electronics are connected through a PXD power cable bundle which may propagate the output noise from the power supplies to the vertex area. This paper presents a study of the propagation of noise caused by power converters in the PXD cable bundle based on Multi-conductor Transmission Line (MTL) theory. The work exposes the effect of the complex cable topology and shield connections on the noise propagation, which has an impact on the requirements of the power supplies. This analysis is part of the electromagnetic compatibility based design focused on functional safety to define the shield connections and power supply specifications required to ensure the successful integration of the detector and, specifically, to achieve the designed performance of the front-end electronics
Performance and Carcass Traits of Market Beef Cattle Supplemented Self-Fed Byproducts on Pasture: A Progress Report
Over a two year period (2007 and 2008), 162 head of beef steers were finished with self-fed byproducts on cool season grass pastures. Yearling steers were continuously grazed at the Neely-Kinyon Farm in southwest Iowa on cool season grasses that were predominantly fescue at a stocking density of 2.25 head/acre. Half of the cattle were implanted (with Synovex®-S) or and half were not. Cattle received a diet of either soyhulls-dried distillers grain with solubles or corn-dried distillers grains with solubles (DDGS) that was offered as a meal through self-feeders. The rations were mixed in at 1:1 with a mineral balancer that included Rumensin®.
Live cattle performance and carcass traits were not affected by diet. Implanted cattle outgained non-implanted over the entire finishing period (3.52 lbs/d vs. 3.17 lbs/d). This led to implanted cattle coming off test heavier (1324 lbs vs. 1277 lbs) and railing with heavier carcasses (826 lbs vs. 800 lbs). Ribeye areas were greater (13.1 in 2 vs. 12.7 in 2 ) for implanted cattle; which was probably due to the heavier carcass weights. Non-implanted cattle had superior quality grades (55% vs. 40%) of low choice or better.
Year differences in quality grade (1023 vs. 985 in 2007 and 2008, respectively) were observed. This difference was attributed to factors that include genetic makeup of cattle, initial weights of cattle, time of year when cattle were harvested and grading technology.
In conclusion, pasture rearing cattle, when given access to self-fed by-products, provides for excellent performance on both live performance and carcass traits. Some considerations should be made by the feeder in regards to time of year when marketing cattle and the cattle’s genetics. This system is an alternative to high-grain conventional beef finishing production in feedlots
Complete Next to Leading Order QCD Corrections to the Photon Structure Functions and
We present the complete NLO QCD analysis of the photon structure functions
and for a real photon target. In
particular we study the heavy flavor content of the structure functions which
is due to two different production mechanisms, namely collisions of a virtual
photon with a real photon, and with a parton. We observe that the charm
contributions are noticeable for as well as
in the x-region studied.Comment: Latex 34 pages, 24 figures, uuencoded, attached at end, ITP-SB-93-46,
FERMILAB-Pub-93/240-T, SMU HEP 93-1
The main concerns of European anaesthesiology postgraduate trainees: A European survey
This is the first study intended to identify the European anaesthesiology trainees' main concerns, to initiate a process of improvement of the training in anaesthesiology by the European Society of Anaesthesiology (ESA). The authors developed an electronic survey which addressed seven different concerns: autonomy transition, technical skills, exchange programs, residency costs, residency workload, employment prospects and educational contents/preparation for the European Diploma in Anaesthesiology and Intensive Care (EDAIC). The survey was disseminated by email to all anaesthesiology trainees registered in ESA and all European National Societies were asked to distribute the survey to their graduating trainees. 665 trainees initiated the survey with a completion rate of 54.6%. The trainees' main concerns were in descending order: educational contents, residency costs, employment prospects, residency workload, exchange programs, technical skills and autonomy transition. This report analyzes the three main concerns in more detail. 68% of respondents were unaware of the existence of the ESA e-learning platform. Other means to improve the preparation for the EDAIC such as a multiple-choice questions book should be developed. The main reason for not becoming an ESA Trainee member was the associated cost and 68% of respondents gave up activities or opportunities during their residency due to economic constraints; 56% of respondents considered emigrating for economic reasons and 28% elected Northern/Central Europe. The results of the present survey may provide additional background information for the development of specific improvements in strategies for training in anaesthesiology. (c) 2018 Elsevier Ltd. All rights reserved
Search for CP violation in tau -> K^0_S pi nu_tau decays at Belle
We report on a search for CP violation in tau -> K^0_S pi nu_tau decays using
a data sample of 699 fb^{-1} collected in the Belle experiment at the KEKB
electron-positron asymmetric-energy collider. The CP asymmetry is measured in
four bins of the invariant mass of the K^0_S pi system and found to be
compatible with zero with a precision of O(10^{-3}) in each mass bin. Limits
for the CP violation parameter Im(eta_S) are given at a 90 % confidence level.
These limits are |Im(eta_S)|<0.026 or better, depending on the parameterization
used to describe the hadronic form factors and improve upon previous limits by
one order of magnitude
Observation of B+ -> Dbar*0 tau+ nu_tau and Evidence for B+ -> Dbar^0 tau+ nu_tau at Belle
We present measurements of B+ -> Dbar*0 tau+ nu_tau and B+ -> Dbar^0 tau+
nu_tau decays in a data sample of 657 x 10^6 BBbar pairs collected with the
Belle detector at the KEKB asymmetric-energy e+e- collider. We find
446^{+58}_{-56} events of the decay B+ -> Dbar*0 tau+ nu_tau with a
significance of 8.1 standard deviations, and 146^{+42}_{-41} events of the
decay B+ -> Dbar0 tau+ nu_tau with a significance of 3.5 standard deviations.
The latter signal provides the first evidence for this decay mode. The measured
branching fractions are B(B+ -> Dbar*0 tau+ nu_tau)=(2.12^{+0.28}_{-0.27}
(stat) +- 0.29 (syst)) % and B(B+ -> Dbar0 tau+ nu_tau)=(0.77 +- 0.22 (stat) +-
0.12 (syst)) %.Comment: 6 pages, 4 figures, submitted to Phys. Rev. Let
Evidence for a new resonance and search for the Y(4140) in
The process \gamma \gamma \to \phi \jpsi is measured for \phi \jpsi
masses between threshold and 5 GeV/, using a data sample of 825
fb collected with the Belle detector. A narrow peak of
events, with a significance of 3.2 standard deviations
including systematic uncertainty, is observed. The mass and natural width of
the structure (named X(4350)) are measured to be
and
, respectively. The
product of its two-photon decay width and branching fraction to \phi\jpsi is
for , or
for . No
signal for the Y(4140)\to \phi \jpsi structure reported by the CDF
Collaboration in B\to K^+ \phi \jpsi decays is observed, and limits of
\Gamma_{\gamma \gamma}(Y(4140)) \BR(Y(4140)\to\phi \jpsi)<41 \hbox{eV} for
or for are determined at the 90% C.L. This
disfavors the scenario in which the Y(4140) is a molecule.Comment: 9 pages, 3 figures, publication in Phys. Rev. Lett. 104, 112004, 201
- …