298 research outputs found

    Innovative Metallic Microfluidic Device for Intensified Biodiesel Production

    Get PDF
    We present a strategy for intensified biodiesel production in a novel metallic microdevice. Additive manufacturing using Selective Laser Melting (SLM) was employed to build the metallic device consisting of multiple micro reactors monolithically integrated with multiple micro heat exchangers. This device allows high conversion rate of biodiesel production with concomitant use of the rejected heat from external source to enhance the reaction temperature and, thereby, its output. The biodiesel production was carried out using soybean oil, ethanol and NaOH as the catalyst. The influences of the reaction temperature and the residence time in the biodiesel production was examined. Biodiesel yield increased with the reaction temperature and a rate of conversion of 99.6% was achieved with a reactor residence time of less than 35 seconds. The work opens up a pathway to exploit waste heat to intensify biodiesel production and contribute significantly to global sustainability

    Genetic diversity analysis in the section Caulorrhizae (genus Arachis) using microsatellite markers

    Get PDF
    Diversity in 26 microsatellite loci from section Caulorrhizae germplasm was evaluated by using 33 accessions of A. pintoi Krapov. & W.C. Gregory and ten accessions of Arachis repens Handro. Twenty loci proved to be polymorphic and a total of 196 alleles were detected with an average of 9.8 alleles per locus. The variability found in those loci was greater than the variability found using morphological characters, seed storage proteins and RAPD markers previously used in this germplasm. The high potential of these markers to detect species-specific alleles and discriminate among accessions was demonstrated. The set of microsatellite primer pairs developed by our group for A. pintoi are useful molecular tools for evaluating Section Caulorrhizae germplasm, as well as that of species belonging to other Arachis sections

    Sheets of vertically aligned BaTiO<sub>3</sub> nanotubes reduce cell proliferation but not viability of NIH-3T3 cells

    Get PDF
    All biomaterials initiate a tissue response when implanted in living tissues. Ultimately this reaction causes fibrous encapsulation and hence isolation of the material, leading to failure of the intended therapeutic effect of the implant. There has been extensive bioengineering research aimed at overcoming or delaying the onset of encapsulation. Nanotechnology has the potential to address this problem by virtue of the ability of some nanomaterials to modulate interactions with cells, thereby inducing specific biological responses to implanted foreign materials. To this effect in the present study, we have characterised the growth of fibroblasts on nano-structured sheets constituted by BaTiO3, a material extensively used in biomedical applications. We found that sheets of vertically aligned BaTiO3 nanotubes inhibit cell cycle progression - without impairing cell viability - of NIH-3T3 fibroblast cells. We postulate that the 3D organization of the material surface acts by increasing the availability of adhesion sites, promoting cell attachment and inhibition of cell proliferation. This finding could be of relevance for biomedical applications designed to prevent or minimize fibrous encasement by uncontrolled proliferation of fibroblastic cells with loss of material-tissue interface underpinning long-term function of implants

    Validation of the questionnaire on beliefs about medication with type 2 diabetic patients

    Get PDF
    O presente trabalho teve como objectivo validar o Questionário Crenças sobre a Medicação, que avalia Crenças Gerais e Crenças Específicas, estudando suas propriedades psicométricas em uma amostra de 387 pacientes diabéticos tipo 2. O estudo de validade para as Crenças Gerais revelou uma solução de um factor, com um alfa de 0,76, e para as Crenças Específicas, dois factores – Necessidades e Preocupações –, com um alfa de 0,77 e 0,69 respectivamente. Quanto à validade de constructo, verificou-se uma relação entre as Crenças Gerais e a subescala Necessidades das Crenças Específicas com Adesão à Medicação, avaliada pela Escala de Avaliação de Aderência Médica. O instrumento apresenta boas qualidades psicométricas para ser utilizado em pacientes diabéticos tipo 2.The present paper focused on the validation of the Questionnaire on Beliefs about Medication, which assesses both General Beliefs and Specific Beliefs. The psychometric properties of the instrument were analyzed on a sample of 387 type 2 diabetic patients. The validity study for General Beliefs found a unifactorial solution, with an alpha of .76, and for Specific Beliefs, a two-factor solution – Necessities and Concern –, with an alpha of .77 and .69, respectively. In terms of construct validity, a relationship between General Beliefs, subscale Necessities from Specific Beliefs, and adherence to medication, as evaluated by Medical Adherence Rating Scale, was found. The instrument presents good psychometric qualities to be used in type 2 diabetic patients.Fundação para a Ciência e Tecnologia (FCT
    • …
    corecore