495 research outputs found

    Notions and subnotions in information structure

    Get PDF
    Three dimensions can be distinguished in a cross-linguistic account of information structure. First, there is the definition of the focus constituent, the part of the linguistic expression which is subject to some focus meaning. Second and third, there are the focus meanings and the array of structural devices that encode them. In a given language, the expression of focus is facilitated as well as constrained by the grammar within which the focus devices operate. The prevalence of focus ambiguity, the structural inability to make focus distinctions, will thus vary across languages, and within a language, across focus meanings

    Average and worst-case specifications of precipitating auroral electron environment

    Get PDF
    The precipitation electrons in the auroral environment are highly variable in their energy and intensity in both space and time. As such they are a source of potential hazard to the operation of the Space Shuttle and other large spacecraft operating in polar orbit. In order to assess these hazards both the average and extreme states of the precipitating electrons must be determined. Work aimed at such a specification is presented. First results of a global study of the average characteristics are presented. In this study the high latitude region was divided into spatial elements in magnetic local time and corrected geomagnetic latitude. The average electron spectrum was then determined in each spatial element for seven different levels of activity as measured by K sub p using an extremely large data set of auroral observations. Second a case study of an extreme auroral electron environment is presented, in which the electrons are accelerated through field aligned potential as high as 30,000 volts and in which the spacecraft is seen to charge negatively to a potential approaching .5 kilovolts

    Editorial: Crosstalk between intonation and lexical tones: Linguistic, cognitive and neuroscience perspectives

    Get PDF
    The interplay between categorical and continuous aspects of the speech signal remains central and yet controversial in the fields of phonetics and phonology. The division between phonological abstractions and phonetic variations has been particularly relevant to the unraveling of diverse communicative functions of pitch in the domain of prosody. Pitch influences vocal communication in two major but fundamentally different ways, and lexical and intonational tones exquisitely capture these functions. Lexical tone contrasts convey lexical meanings as well as derivational meanings at the word level and are grammatically encoded as discrete structures. Intonational tones, on the other hand, signal post-lexical meanings at the phrasal level and typically allow gradient pragmatic variations. Since categorical and gradient uses of pitch are ubiquitous and closely intertwined in their physiological and psychological processes, further research is warranted for a more detailed understanding of their structural and functional characterisations. This Research Topic addresses this matter from a wide range of perspectives, including first and second language acquisition, speech production and perception, structural and functional diversity, and working with distinct languages and experimental measures. In the following, we provide a short overview of the contributions submitted to this topi

    Universal and language-specific effects in the perception of question intonation

    Get PDF
    Three groups of monolingual listeners, with Standard Chinese, Dutch and Hungarian as their native language, judged pairs of trisyllabic stimuli which differed only in their itch pattern. The segmental structure of the stimuli was made up by the experimenters and presented to subjects as being taken from a little-known language spoken on a South Pacific island. Pitch patterns consisted of a single rise-fall located on or near the second syllable. By and large, listeners selected the stimulus with the higher peak, the later eak, and the higher end rise as the one that signalled a question, regardless of language group. The result is argued to reflect innate, non-linguistic knowledge of the meaning of pitch variation, notably Ohala’s Frequency Code. A significant difference between groups is explained as due to the influence of the mother tongue

    The sequence recall task and lexicality of tone: Exploring tone “deafness”

    Get PDF
    Many perception and processing effects of the lexical status of tone have been found in behavioral, psycholinguistic, and neuroscientific research, often pitting varieties of tonal Chinese against non-tonal Germanic languages. While the linguistic and cognitive evidence for lexical tone is therefore beyond dispute, the word prosodic systems of many languages continue to escape the categorizations of typologists. One controversy concerns the existence of a typological class of “pitch accent languages,” another the underlying phonological nature of surface tone contrasts, which in some cases have been claimed to be metrical rather than tonal. We address the question whether the Sequence Recall Task (SRT), which has been shown to discriminate between languages with and without word stress, can distinguish languages with and without lexical tone. Using participants from non-tonal Indonesian, semi-tonal Swedish, and two varieties of tonal Mandarin, we ran SRTs with monosyllabic tonal contrasts to test the hypothesis that high performance in a tonal SRT indicates the lexical status of tone. An additional question concerned the extent to which accuracy scores depended on phonological and phonetic properties of a language’s tone system, like its complexity, the existence of an experimental contrast in a language’s phonology, and the phonetic salience of a contrast. The results suggest that a tonal SRT is not likely to discriminate between tonal and non-tonal languages within a typologically varied group, because of the effects of specific properties of their tone systems. Future research should therefore address the first hypothesis with participants from otherwise similar tonal and non-tonal varieties of the same language, where results from a tonal SRT may make a useful contribution to the typological debate on word prosody

    Voiced fricatives in Dutch: sources and present-day usage

    Get PDF
    De geschiedenis van het Engels: taalkunde en historiografi

    Intravascular ultrasonography allows accurate assessment of abdominal aortic aneurysm: An in vitro validation study

    Get PDF
    AbstractObjective: The objective of this study was to acquire insight into the interpretation of intravascular ultrasound images of the abdominal aorta and to assess to what extent this technique can provide useful parameters for the endovascular treatment of patients with abdominal aortic aneurysm. Study Design: This was a descriptive study. Methods: Fifteen abdominal aortic specimens (normal, atherosclerotic, or aneurysmal) were studied. Ultrasonic images and corresponding histologic sections were compared for vessel wall characteristics, lesion morphologic characteristics, and lumen diameter. The length of the aneurysm and the length of the proximal and distal neck were measured and compared with external measurements. Tomographic images were reconstructed to a three-dimensional format. Results: Normal aortic wall was seen as a two- or three-layered structure corresponding with intima, media, and adventitia. A distinction could be made among fibrous lesion, calcified lesion, and thrombus and between normal and aneurysmal aorta. Correlation between the histologic specimens and intravascular ultrasonography for lumen diameter measurements was high (r = 0.93; p < 0.001). In a similar fashion, correlation between external measurements and intravascular ultrasound measurements on the length of the aneurysm and its proximal and distal neck was high (r = 0.99; p < 0.001). Three-dimensional analysis enhanced interpretation of the tomographic images by visualizing the spatial position of anatomic structures and contributed to understanding the shape and dimensions of the aneurysm. Conclusions: Intravascular ultrasonography provides accurate information on the vessel wall, lesion morphologic characteristics, and quantitative parameters of the abdominal aorta. Spatial information supplied by three-dimensional analysis contributes to a more realistic interpretation of the tomographic images. (J Vasc Surg 1998;27:347-53.

    Accurate assessment of abdominal aortic aneurysm with intravascular ultrasound scanning: Validation with computed tomographic angiography

    Get PDF
    AbstractPurpose: The purpose of this study was to assess the accuracy of intravascular ultrasound (IVUS) parameters of abdominal aortic aneurysm, used for endovascular grafting, in comparison with computed tomographic angiography (CTA). Methods: This study was designed as a descriptive study. Between March 1997 and March 1998, 16 patients with abdominal aortic aneurysms were studied with angiography, IVUS (12.5 MHz), and CTA. The length of the aneurysm and the length and lumen diameter of the proximal and distal neck obtained with IVUS were compared with the data obtained with CTA. The measurements with IVUS were repeated by a second observer to assess the reproducibility. Tomographic IVUS images were reconstructed into a longitudinal format. Results: IVUS results identified 31 of 32 renal arteries and four of five accessory renal arteries. A comparison of the length measurements of the aneurysm and the proximal and distal neck obtained with IVUS and CTA revealed a correlation of 0.99 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate the length as compared with the CTA results (0.48 ± 0.52 cm; P < .001). A comparison of the lumen diameter measurements of the proximal and distal neck derived from IVUS and CTA showed a correlation of 0.93 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate aneurysm neck diameter as compared with CTA results (0.68 ± 1.76 mm; P = .006). Interobserver agreement of IVUS length and diameter measurements showed a good correlation (r = 1.0; P < .001), with coefficients of variation of 3% and 2%, respectively, and no significant differences (0.0 ± 0.16 cm and 0.06 ± 0.36 mm, respectively). The longitudinal IVUS images displayed the important vascular structures and improved the spatial insight in aneurysmal anatomy. Conclusion: Intravascular ultrasound scanning results provided accurate and reproducible measurements of abdominal aortic aneurysm. The longitudinal reconstruction of IVUS images provided additional knowledge on the anatomy of the aneurysm and its proximal and distal neck. (J Vasc Surg 1999;29:631-8.
    corecore