116 research outputs found

    X-ray full field microscopy at 30 KeV

    Get PDF
    In our X-ray full field microscopy experiments, we demonstrated a resolution better than 260 nm over the entire field of view of 80 ÎŒm x 80 ÎŒm at 30 keV. Our experimental setup at PETRA III, P05, had a length of about 5 m consisting of an illumination optics, an imaging lens and a detector. For imaging, we used a compound refractive lens (CLR) consisting of mr-L negative photo resist, which was fabricated by deep X-ray lithography. As illumination optics, we choose a refractive rolled X-ray prism lens, which was adapted to the numerical aperture of the imaging lens

    Machine learning denoising of high-resolution X-ray nanotomography data

    Get PDF
    High-resolution X-ray nano­tomography is a quantitative tool for investigating specimens from a wide range of research areas. However, the quality of the reconstructed tomogram is often obscured by noise and therefore not suitable for automatic segmentation. Filtering methods are often required for a detailed quantitative analysis. However, most filters induce blurring in the reconstructed tomograms. Here, machine learning (ML) techniques offer a powerful alternative to conventional filtering methods. In this article, we verify that a self-supervised denoising ML technique can be used in a very efficient way for eliminating noise from nano­tomography data. The technique presented is applied to high-resolution nano­tomography data and compared to conventional filters, such as a median filter and a nonlocal means filter, optimized for tomographic data sets. The ML approach proves to be a very powerful tool that outperforms conventional filters by eliminating noise without blurring relevant structural features, thus enabling efficient quantitative analysis in different scientific fields

    Nanotomography endstation at the P05 beamline : Status and perspectives

    Get PDF
    The Imaging Beamline IBL/P05 at the DESY storage ring PETRA III, operated by the Helmholtz-Zentrum Geesthacht, has two dedicated endstations optimized for micro- and nanotomography experiments [1-3]. Here we present the status of the nanotomography endstation, highlight the latest instrumentation upgrades and present first experimental results. In particular in materials science, where structures with ceramics or metallic materials are of interest, X-ray energies of 15 keV and above are required even for sample sizes of several 10 ÎŒm in diameter. The P05 imaging beamline is dedicated to materials science and is designed to allow for imaging applications with X-ray energies of 10 to 50 keV. In addition to the full field X-ray microscopy setup, the layout of the nanotomography endstation allows switching to cone-beam configuration. Kinematics for X-ray optics like compound refractive lenses (CRLs), Fresnel zone plates (FZP) or beam-shaping optics are implemented and the installation of a Kirkpatrick Baez-mirror (KB mirror) system is foreseen at a later stage of the beamline development. Altogether this leads to a high flexibility of the nanotomography setup such that the instrument can be tailored to the specific experimental requirements of a range of sample systems

    Pushing the temporal resolution in absorption and Zernike phase contrast nanotomography: Enabling fast in situ experiments

    Get PDF
    Hard X-ray nanotomography enables 3D investigations of a wide range of samples with high resolution (<100 nm) with both synchrotron-based and laboratory-based setups. However, the advantage of synchrotron-based setups is the high flux, enabling time resolution, which cannot be achieved at laboratory sources. Here, the nanotomography setup at the imaging beamline P05 at PETRA III is presented, which offers high time resolution not only in absorption but for the first time also in Zernike phase contrast. Two test samples are used to evaluate the image quality in both contrast modalities based on the quantitative analysis of contrast-to-noise ratio (CNR) and spatial resolution. High-quality scans can be recorded in 15 min and fast scans down to 3 min are also possible without significant loss of image quality. At scan times well below 3 min, the CNR values decrease significantly and classical image-filtering techniques reach their limitation. A machine-learning approach shows promising results, enabling acquisition of a full tomography in only 6 s. Overall, the transmission X-ray microscopy instrument offers high temporal resolution in absorption and Zernike phase contrast, enabling in situ experiments at the beamline

    Reasons of general practitioners for not prescribing lipid-lowering medication to patients with diabetes: a qualitative study

    Get PDF
    Background: Lipid-lowering medication remains underused, even in high-risk populations. The objective of this study was to determine factors underlying general practitioners' decisions not to prescribe such drugs to patients with type 2 diabetes. Methods: A qualitative study with semi-structured interviews using real cases was conducted to explore reasons for not prescribing lipid-lowering medication after a guideline was distributed that recommended the use of statins in most patients with type 2 diabetes. Seven interviews were conducted with general practitioners (GPs) in The Netherlands, and analysed using an analytic inductive approach. Results: Reasons for not-prescribing could be divided into patient and physician-attributed factors. According to the GPs, some patients do not follow-up on agreed medication and others object to taking lipid-lowering medication, partly for legitimate reasons such as expected or perceived side effects. Furthermore, the GPs themselves perceived reservations for prescribing lipid-lowering medication in patients with short life expectancy, expected compliance problems or near goal lipid levels. GPs sometimes postponed the start of treatment because of other priorities. Finally, barriers were seen in the GPs' practice organisation, and at the primary-secondary care interface. Conclusion: Some of the barriers mentioned by GPs seem to be valid reasons, showing that guideline non-adherence can be quite rational. On the other hand, treatment quality could improve by addressing issues, such as lack of knowledge or motivation of both the patient and the GP. More structured management in general practice may also lead to better treatment

    Differential Scanning Fluorimetry provides high throughput data on silk protein transitions

    Get PDF
    Here we present a set of measurements using Differential Scanning Fluorimetry (DSF) as an inexpensive, high throughput screening method to investigate the folding of silk protein molecules as they abandon their first native melt conformation, dehydrate and denature into their final solid filament conformation. Our first data and analyses comparing silks from spiders, mulberry and wild silkworms as well as reconstituted ‘silk’ fibroin show that DSF can provide valuable insights into details of silk denaturation processes that might be active during spinning. We conclude that this technique and technology offers a powerful and novel tool to analyse silk protein transitions in detail by allowing many changes to the silk solutions to be tested rapidly with microliter scale sample sizes. Such transition mechanisms will lead to important generic insights into the folding patterns not only of silks but also of other fibrous protein (bio)polymers

    What differentiates primary care physicians who predominantly prescribe diuretics for treating mild to moderate hypertension from those who do not? A comparative qualitative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Thiazide diuretics are cost-effective for the treatment of mild to moderate hypertension, but physicians often opt for more expensive treatment options such as angiotensin II receptor blockers or angiotensin converting enzyme inhibitors. With escalating health care costs, there is a need to elucidate the factors influencing physicians' treatment choices for this highly prevalent chronic condition. The purpose of this study was to describe the characteristics of physicians' decision-making process regarding hypertension treatment choices.</p> <p>Methods</p> <p>A comparative qualitative study was conducted in 2009 in the Canadian province of Quebec. Overall, 29 primary care physicians--who are also participating in an electronic health record research program--participated in a semi-structured interview about their prescribing decisions. Physicians were categorized into two groups based on their patterns of prescribing antihypertensive drugs: physicians who predominantly prescribe diuretics, and physicians who predominantly prescribe drug classes other than diuretics. Cases of hypertension that were newly started on antihypertensive therapy were purposely selected from each physician's electronic health record database. Chart stimulated recall interview, a technique utilizing patient charts to probe recall and provide context to physician decision-making during clinical encounters, was used to elucidate reasons for treatment choices. Interview transcripts were synthesized using content analysis techniques, and factors influencing physicians' decision making were inductively generated from the data.</p> <p>Results</p> <p>We identified three themes that differentiated physicians who predominantly prescribe diuretics from those who predominantly prescribe other drug classes for the initial treatment of mild to moderate hypertension: a) perceptions about the efficacy of diuretics, b) preferred approach to hypertension management and, c) perceptions about hypertension guidelines. Specifically, physicians had differences in beliefs about the efficacy, safety and tolerability of diuretics, the most effective approach for managing mild to moderate hypertension, and in aggressiveness to achieve treatment targets. Marketing strategies employed by the pharmaceutical industry and practice experience appear to contribute to these differences in management approach.</p> <p>Conclusions</p> <p>Physicians preferring more expensive treatment options appear to have several misperceptions about the efficacy, safety and tolerability of diuretics. Efforts to increase physicians' prescribing of diuretics may need to be directed at overcoming these misperceptions.</p

    Flexible plenoptic X-ray microscopy

    Get PDF
    X-ray computed tomography (CT) is an invaluable technique for generating three-dimensional (3D) images of inert or living specimens. X-ray CT is used in many scientific, industrial, and societal fields. Compared to conventional 2D X-ray imaging, CT requires longer acquisition times because up to several thousand projections are required for reconstructing a single high-resolution 3D volume. Plenoptic imaging—an emerging technology in visible light field photography—highlights the potential of capturing quasi-3D information with a single exposure. Here, we show the first demonstration of a flexible plenoptic microscope operating with hard X-rays; it is used to computationally reconstruct images at different depths along the optical axis. The experimental results are consistent with the expected axial refocusing, precision, and spatial resolution. Thus, this proof-of-concept experiment opens the horizons to quasi-3D X-ray imaging, without sample rotation, with spatial resolution of a few hundred nanometres

    Clinical course of untreated cerebral cavernous malformations: A meta-analysis of individual patient data

    Get PDF
    SummaryBackgroundCerebral cavernous malformations (CCMs) can cause symptomatic intracranial haemorrhage (ICH), but the estimated risks are imprecise and predictors remain uncertain. We aimed to obtain precise estimates and predictors of the risk of ICH during untreated follow-up in an individual patient data meta-analysis.MethodsWe invited investigators of published cohorts of people aged at least 16 years, identified by a systematic review of Ovid MEDLINE and Embase from inception to April 30, 2015, to provide individual patient data on clinical course from CCM diagnosis until first CCM treatment or last available follow-up. We used survival analysis to estimate the 5-year risk of symptomatic ICH due to CCMs (primary outcome), multivariable Cox regression to identify baseline predictors of outcome, and random-effects models to pool estimates in a meta-analysis.FindingsAmong 1620 people in seven cohorts from six studies, 204 experienced ICH during 5197 person-years of follow-up (Kaplan-Meier estimated 5-year risk 15·8%, 95% CI 13·7–17·9). The primary outcome of ICH within 5 years of CCM diagnosis was associated with clinical presentation with ICH or new focal neurological deficit (FND) without brain imaging evidence of recent haemorrhage versus other modes of presentation (hazard ratio 5·6, 95% CI 3·2–9·7) and with brainstem CCM location versus other locations (4·4, 2·3–8·6), but age, sex, and CCM multiplicity did not add independent prognostic information. The 5-year estimated risk of ICH during untreated follow-up was 3·8% (95% CI 2·1–5·5) for 718 people with non-brainstem CCM presenting without ICH or FND, 8·0% (0·1–15·9) for 80 people with brainstem CCM presenting without ICH or FND, 18·4% (13·3–23·5) for 327 people with non-brainstem CCM presenting with ICH or FND, and 30·8% (26·3–35·2) for 495 people with brainstem CCM presenting with ICH or FND.InterpretationMode of clinical presentation and CCM location are independently associated with ICH within 5 years of CCM diagnosis. These findings can inform decisions about CCM treatment.FundingUK Medical Research Council, Chief Scientist Office of the Scottish Government, and UK Stroke Association

    Women performing repetitive work: Is there a difference in the prevalence of shoulder pain and pathology in supermarket cashiers compared to the general female population?

    Get PDF
    Objectives: Shoulder disorders in the occupational environment have been widely studied, but the quality of research and methodology applied vary. Little has been done to ascertain whether shoulder pain in female repetitive workers is due to any verifiable pathology, or to compare findings with the general population. Therefore, we decided to evaluate the prevalence of self-reported shoulder pain in a group of female supermarket cashiers and in the general female population using a standardized questionnaire. Shoulder pain prevalence was then compared to imaging findings in order to assess specific and non-specific pain prevalence. Material and Methods: 196 cashiers and 302 controls filled in a standardized shoulder questionnaire and underwent an imaging examination of a shoulder. Results: The prevalence of shoulder pain was significantly higher in the group of cashiers (46.4%) than in the general population (25.5%) (OR = 1.821; 95% CI: 1.426–2.325). Specific pain prevalence was higher among the controls (19.5%) than among the cashiers (13.2%). Conclusions: The more frequent reports of shoulder pain in the supermarket cashiers are not correlated with a higher prevalence of imaging abnormalities. The causes of these more frequent complaints should be probably sought in the psycho-social and occupational environment
    • 

    corecore