277 research outputs found

    Music enrichment for gifted children in the first grade

    Full text link
    Thesis (Ed.M.)--Boston Universit

    Prenatal to Grade 3 Alignment Initiative

    Get PDF
    The purpose of this project is to create stronger connections between elementary schools & providers of early childhood care/education programs; and between schools & parents of young children in 10 grantee communities across Oregon. The evaluation team developed data collection tools and is currently providing data collection and utilization training and technical assistance, and conducting systems evaluation data collection and analysis

    The streptococcal collagen-like protein-1 (Scl1) is a significant determinant for biofilm formation by group a Streptococcus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Group A <it>Streptococcus </it>(GAS) is a human-specific pathogen responsible for a number of diseases characterized by a wide range of clinical manifestations. During host colonization GAS-cell aggregates or microcolonies are observed in tissues. GAS biofilm, which is an <it>in vitro </it>equivalent of tissue microcolony, has only recently been studied and little is known about the specific surface determinants that aid biofilm formation. In this study, we demonstrate that surface-associated streptococcal collagen-like protein-1 (Scl1) plays an important role in GAS biofilm formation.</p> <p>Results</p> <p>Biofilm formation by M1-, M3-, M28-, and M41-type GAS strains, representing an intraspecies breadth, were analyzed spectrophotometrically following crystal violet staining, and characterized using confocal and field emission scanning electron microscopy. The M41-type strain formed the most robust biofilm under static conditions, followed by M28- and M1-type strains, while the M3-type strains analyzed here did not form biofilm under the same experimental conditions. Differences in architecture and cell-surface morphology were observed in biofilms formed by the M1- and M41-wild-type strains, accompanied by varying amounts of deposited extracellular matrix and differences in cell-to-cell junctions within each biofilm. Importantly, all Scl1-negative mutants examined showed significantly decreased ability to form biofilm <it>in vitro</it>. Furthermore, the Scl1 protein expressed on the surface of a heterologous host, <it>Lactococcus lactis</it>, was sufficient to induce biofilm formation by this organism.</p> <p>Conclusions</p> <p>Overall, this work (i) identifies variations in biofilm formation capacity among pathogenically different GAS strains, (ii) identifies GAS surface properties that may aid in biofilm stability and, (iii) establishes that the Scl1 surface protein is an important determinant of GAS biofilm, which is sufficient to enable biofilm formation in the heterologous host <it>Lactococcus</it>. In summary, the GAS surface adhesin Scl1 may have an important role in biofilm-associated pathogenicity.</p

    A Spitzer Study of Comets 2P/Encke, 67P/Churyumov-Gerasimenko, and C/2001 HT50 (LINEAR-NEAT)

    Get PDF
    We present infrared images and spectra of comets 2P/Encke, 67P/Churyumov-Gerasimenko, and C/2001 HT50 (LINEAR-NEAT) as part of a larger program to observe comets inside of 5 AU from the sun with the Spitzer Space Telescope. The nucleus of comet 2P/Encke was observed at two vastly different phase angles (20 degrees and 63 degrees). Model fits to the spectral energy distributions of the nucleus suggest comet Encke's infrared beaming parameter derived from the near-Earth asteroid thermal model may have a phase angle dependence. The observed emission from comet Encke's dust coma is best-modeled using predominately amorphous carbon grains with a grain size distribution that peaks near 0.4 microns, and the silicate contribution by mass to the sub-micron dust coma is constrained to 31%. Comet 67P/Churyumov-Gerasimenko was observed with distinct coma emission in excess of a model nucleus at a heliocentric distance of 5.0 AU. The coma detection suggests that sublimation processes are still active or grains from recent activity remain near the nucleus. Comet C/2001 HT50 (LINEAR-NEAT) showed evidence for crystalline silicates in the spectrum obtained at 3.2 AU and we derive a silicate-to-carbon dust ratio of 0.6. The ratio is an order of magnitude lower than that derived for comets 9P/Tempel 1 during the Deep Impact encounter and C/1995 O1 (Hale-Bopp).Comment: Accepted for publication in the Astrophysical Journal 48 pages, 15 figures, 10 table

    Water in Comets 71P/Clark and C/2004 B1 (LINEAR) with Spitzer

    Get PDF
    We present 5.5 to 7.6 micron spectra of comets 71P/Clark (2006 May 27.56 UT, r_h = 1.57 AU pre-perihelion) and C/2004 B1 (LINEAR) (2005 October 15.22 UT, r_h = 2.21 AU pre-perihelion and 2006 May 16.22 UT, r_h = 2.06 AU post-perihelion) obtained with the Spitzer Space Telescope. The nu_2 vibrational band of water is detected with a signal-to-noise ratio of 11 to 50. Fitting the spectra using a fluorescence model of water emission yields a water rotational temperature of < 18 K for 71P/Clark and approximately less than or equivalent to 14 +/- 2 K (pre-perihelion) and 23 +/- 4 K (post-perihelion) for C/2004 B1 (LINEAR). The water ortho-to-para ratio in C/2004 B1 (LINEAR) is measured to be 2.31 +/- 0.18, which corresponds to a spin temperature of 26^{+3}_{-2} K. Water production rates are derived. The agreement between the water model and the measurements is good, as previously found for Spitzer spectra of C/2003 K4 (LINEAR). The Spitzer spectra of these three comets do not show any evidence for emission from PAHs and carbonate minerals, in contrast to results reported for comets 9P/Tempel~1 and C/1995 O1 (Hale-Bopp).Comment: 16 pages, 1 table, 7 figures, ApJ accepted 200

    Engaging African American breast cancer survivors in an intervention trial: culture, responsiveness and community

    Get PDF
    Younger breast cancer survivors often lead extremely busy lives with multiple demands and responsibilities, making them difficult to recruit into clinical trials. African American women are even more difficult to recruit because of additional historical and cultural barriers. In a randomized clinical trial of an intervention, we successfully used culturally informed, population-specific recruitment and retention strategies to engage younger African-American breast cancer survivors

    Freshwater shrimp (Palaemonetes australis) as a potential bioindicator of crustacean health

    Get PDF
    Palaemonetes australis is a euryhaline shrimp found in south-western Australian estuaries. To determine if P. australis is a suitable bioindicator species for monitoring the health of estuarine biota, they were exposed to measured concentrations of the polycyclic aromatic hydrocarbon, benzo[a]pyrene (B[a]P) at 0.01, 0.1 or 1 ppm for 14 days under laboratory conditions. At the end of exposure the shrimp were sacrificed for biomarker [ethoxycoumarin O-deethylase (ECOD), 8-oxo-dG concentration, and sorbitol dehydrogenase (SDH) activity] analyses. Gender did not appear to influence biomarker responses of the shrimp in this study. ECOD activity was induced in the treatment groups in a linear fashion from 3 (0.01 ppm) times to 12 (1 ppm) times the negative controls. 8-oxo-dG concentration was reduced 3 times in treatment groups below the controls suggesting impaired DNA repair pathways. There was no increase in SDH, signifying hepatopancreatic cell damage had not occurred in any treatment group. The response of P australis to B[a]P exposure indicates that this crustacean is suitable bioindicator species for both laboratory studies and field monitoring. A combination of ECOD and SDH activities and 8-oxo-dG concentration represent a suitable suite of biomarkers for environmental monitoring of the sublethal effects of organic pollution to crustaceans from an estuarine environment

    The Sound Sensation of Apical Electric Stimulation in Cochlear Implant Recipients with Contralateral Residual Hearing

    Get PDF
    BACKGROUND: Studies using vocoders as acoustic simulators of cochlear implants have generally focused on simulation of speech understanding, gender recognition, or music appreciation. The aim of the present experiment was to study the auditory sensation perceived by cochlear implant (CI) recipients with steady electrical stimulation on the most-apical electrode. METHODOLOGY/PRINCIPAL FINDINGS: Five unilateral CI users with contralateral residual hearing were asked to vary the parameters of an acoustic signal played to the non-implanted ear, in order to match its sensation to that of the electric stimulus. They also provided a rating of similarity between each acoustic sound they selected and the electric stimulus. On average across subjects, the sound rated as most similar was a complex signal with a concentration of energy around 523 Hz. This sound was inharmonic in 3 out of 5 subjects with a moderate, progressive increase in the spacing between the frequency components. CONCLUSIONS/SIGNIFICANCE: For these subjects, the sound sensation created by steady electric stimulation on the most-apical electrode was neither a white noise nor a pure tone, but a complex signal with a progressive increase in the spacing between the frequency components in 3 out of 5 subjects. Knowing whether the inharmonic nature of the sound was related to the fact that the non-implanted ear was impaired has to be explored in single-sided deafened patients with a contralateral CI. These results may be used in the future to better understand peripheral and central auditory processing in relation to cochlear implants

    Efficiency and safety of varying the frequency of whole blood donation (INTERVAL): a randomised trial of 45 000 donors

    Get PDF
    Background: Limits on the frequency of whole blood donation exist primarily to safeguard donor health. However, there is substantial variation across blood services in the maximum frequency of donations allowed. We compared standard practice in the UK with shorter inter-donation intervals used in other countries. Methods: In this parallel group, pragmatic, randomised trial, we recruited whole blood donors aged 18 years or older from 25 centres across England, UK. By use of a computer-based algorithm, men were randomly assigned (1:1:1) to 12-week (standard) versus 10-week versus 8-week inter-donation intervals, and women were randomly assigned (1:1:1) to 16-week (standard) versus 14-week versus 12-week intervals. Participants were not masked to their allocated intervention group. The primary outcome was the number of donations over 2 years. Secondary outcomes related to safety were quality of life, symptoms potentially related to donation, physical activity, cognitive function, haemoglobin and ferritin concentrations, and deferrals because of low haemoglobin. This trial is registered with ISRCTN, number ISRCTN24760606, and is ongoing but no longer recruiting participants. Findings: 45 263 whole blood donors (22 466 men, 22 797 women) were recruited between June 11, 2012, and June 15, 2014. Data were analysed for 45 042 (99·5%) participants. Men were randomly assigned to the 12-week (n=7452) versus 10-week (n=7449) versus 8-week (n=7456) groups; and women to the 16-week (n=7550) versus 14-week (n=7567) versus 12-week (n=7568) groups. In men, compared with the 12-week group, the mean amount of blood collected per donor over 2 years increased by 1·69 units (95% CI 1·59–1·80; approximately 795 mL) in the 8-week group and by 0·79 units (0·69–0·88; approximately 370 mL) in the 10-week group (p&lt;0·0001 for both). In women, compared with the 16-week group, it increased by 0·84 units (95% CI 0·76–0·91; approximately 395 mL) in the 12-week group and by 0·46 units (0·39–0·53; approximately 215 mL) in the 14-week group (p&lt;0·0001 for both). No significant differences were observed in quality of life, physical activity, or cognitive function across randomised groups. However, more frequent donation resulted in more donation-related symptoms (eg, tiredness, breathlessness, feeling faint, dizziness, and restless legs, especially among men [for all listed symptoms]), lower mean haemoglobin and ferritin concentrations, and more deferrals for low haemoglobin (p&lt;0·0001 for each) than those observed in the standard frequency groups. Interpretation: Over 2 years, more frequent donation than is standard practice in the UK collected substantially more blood without having a major effect on donors' quality of life, physical activity, or cognitive function, but resulted in more donation-related symptoms, deferrals, and iron deficiency. Funding: NHS Blood and Transplant, National Institute for Health Research, UK Medical Research Council, and British Heart Foundation
    corecore