174 research outputs found

    A low power colour-based skin detectors for smart environments

    Get PDF
    We describe an embedded optical system detecting human skin under a wide range of illuminant conditions. Our attention to such a system is justified by the many applications for which skin detection is needed, e.g. automatic people monitoring and tracking for security reasons or hand gesture recognition for fast and natural human-machine interaction. The presented system consists of a low power RGB sensor connected to an energy efficient microcontroller. The RGB sensor acquires the RGB signal from a region in front of it over a wide dynamic range, converts it in the rg chromaticity space directly on chip and delivers the processed data to the microcontroller. This latter classifies the input signal as skin or non-skin, testing its membership to a skin locus, i.e. to a compact set representing the chromaticities of the human skin tones acquired under several illuminant conditions. The system architecture distributes the computational load of skin detection on both hardware and software, providing a reliable skin detection with a limited energy consumption. This makes the system suitable to be used in smart environments, where energy efficiency is highly desired in order to keep the sensors always ready to receive, process and transmit data without affecting the performance

    Continuous low flow ascites drainage through the urinary bladder via the Alfapump system in palliative patients with malignant ascites.

    Get PDF
    BACKGROUND Malignant Ascites (MA) is a therapeutic dilemma significantly impairing patients' quality of life (QoL). The Sequana Medical alfapump System (AP), a subcutaneous, externally rechargeable, implantable device, continually draining ascites via the urinary bladder, has been well established in liver cirrhosis, but not yet in MA. The AP-system was evaluated in cancer patients in reducing the need for large volume paracentesis (LVP). METHODS A retrospective multicentre evaluation of all eligible patients who received an AP for MA-palliation was performed. AP was evaluated for its ability to reduce LVP and cross-correlated with adverse events (AE), survival and retrospective physician-reported QoL. RESULTS Seventeen patients with median age of 63 years (range: 18-81), 70.6% female, across 7 primary tumour types were analysed. Median duration of AP-implantation was 60 min (range: 30-270) and median post-implantation hospital stay: 4 days (range: 2-24). Twelve protocol-defined AE occurred in 5 patients (29.4%): 4 kidney failures, 4 pump/catheter-related blockages, 3 infections/peritonitis and 1 wound dehiscence. Median ascitic volume (AV) pumped daily was 303.6 ml/day (range:5.6-989.3) and median total AV drained was 28 L (range: 1-638.6). Median patient post-AP-survival was 111 days (range:10-715) and median pump survival was 89 days (range: 0-715). Median number of paracenteses was 4 (range: 1-15) per patient pre-implant versus 1 (range: 0-1) post-implant (p = 0.005). 71% of patients were reported to have an improvement of at least one physician reported QoL-parameters. CONCLUSIONS AP appears to be effective in palliating patients with MA by an acceptable morbidity profile. Its broader implementation in oncology services should be further explored. TRIAL REGISTRATION NCT03200106; June 27, 2017

    PENGARUH NEGARA ASAL, CITRA MEREK DAN KEPERCAYAAN MEREK TERHADAP PERSEPSI DARI KUALITAS PRODUK ETUDE HOUSE KOREA SELATAN

    Get PDF
    The aim of this research is to know the influence of country of origin, brand image and brand trust on perception of Etude House of South Korea Product Quality. Total sample used is 100 respondents as user of Etude House. The techique of analysis used is Structural Equation Modeling (SEM) with AMOS 18. The result shown that country of origin has an effect on perception of product quality, brand image has an effect on perception of product quality and brand trust can positively mediate country of origin and the perception of product quality

    Preliminary assessment of fentanyl and synthetic opioids prevalence among addiction patients by means of hair analysis

    Get PDF
    Background Although the diffusion of novel synthetic opioids has become a worldwide phenomenon, their prevalence of use in Italy seems to be limited. Existing national data is mainly derived by anamnestic surveyslacking of toxicological validation and not always disclosing the use of these compounds, which might remain under-diagnosed. Methods an assessment of the metabolites of the main synthetic opioids on hair samples was carried out among patients admitted at the Addiction Treatment Unit of Trento. The analytical approach included: (a) screening by means of immunoenzymatic method for fentanyl, fentanyl analogs and oxicodone; (b) confirmation of the samples resulted positive for fentanyl and oxicodone by means of HPLC-MS/; (c) search and dosage detection of Tramadol by means of HPLC-MS/MS. Results 3 out of 309 analysed samples were found positive: one was positive to Fentanyl and two to 4-ANPP. In the same cohort, 6 samples were also found positive for Oxycodone . Tramadol was searched in 189 samples and 12 of them resulted positive. Discussion and conclusion Those found positive were mainly young adults engaging in dangerous patterns of use and lacking awareness of risks. The phenomenon requires further consideration by health professionals. Training and more evidence-based information on synthetic opioids as well as other Novel Psychoactive Substances (NPS) are urgently needed.Peer reviewe

    The tumor microenvironment of colorectal cancer: stromal TLR-4 expression as a potential prognostic marker

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Colorectal cancer can be efficiently treated when found at early stages, thus the search for novel markers is of paramount importance. Since inflammation is associated with cancer progression and angiogenesis, we investigated expression of cytokines like IL-6 and other mediators that play a key role in the innate immune system, in particular toll like receptor 4 (TLR4), in the microenvironment of lesions from different stages of colon disease progression, from ulcerative colitis to adenoma and adenocarcinoma to find useful markers.</p> <p>Methods</p> <p>The presence of inflammatory cells and expression of key cytokines involved in the inflammation process were quantified by immunohistochemistry in specific tissue compartments (epithelial, stromal, endothelial) by immunohistochemistry. A murine azoxymethane/dextran sulfate model in which Tir8, a negative regulator of the inflammatory response, was ablated was used to confirm the clinical observations. 116 Archival tissue samples from patients with different stages of colorectal disease: 13 cases of ulcerative colitis (UC), 34 tubular or tubulo-villous adenomas (AD), and 53 infiltrating adenocarcinomas. 16 specimens of healthy mucosa surgically removed with the cancerous tissue were used as a control.</p> <p>Results</p> <p>The differences between healthy tissues and the diverse lesions was characterized by a marked inflammatory-angiogenic reaction, with significantly (P < 0.05) higher numbers of CD68, CD15, and CD31 expressing cells in all diseased tissues that correlated with increasing grade of malignancy. We noted down-regulation of a potential modulator molecule, Hepatocyte Growth Factor, in all diseased tissues (P < 0.05). TLR-4 and IL6 expression in the tumor microenvironment were associated with adenocarcinoma in human samples and in the murine model. We found that adenocarcinoma patients (pT1-4) with higher TLR-4 expression in stromal compartment had a significantly increased risk in disease progression. In those patients with a diagnosis of pT3 (33 cases) colon cancer, those with very high levels of TLR-4 in the tumor stroma relapsed significantly earlier than those with lower expression levels.</p> <p>Conclusions</p> <p>These data suggest that high TLR-4 expression in the tumor microenvironment represents a possible marker of disease progression in colon cancer.</p

    Disposition of Phytocannabinoids, Their Acidic Precursors and Their Metabolites in Biological Matrices of Healthy Individuals Treated with Vaporized Medical Cannabis

    Get PDF
    Inhalation by vaporization is a useful application mode for medical cannabis. In this study, we present the disposition of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), their acidic precursors, and their metabolites in serum, oral fluid, and urine together with the acute pharmacological effects in 14 healthy individuals treated with vaporized medical cannabis. THC and CBD peaked firstly in serum and then in oral fluid, with higher concentrations in the first biological matrices and consequent higher area under the curve AUCs. Acidic precursors Δ-9-tetrahydrocannabinolic acid A (THCA) and cannabidiolic acid (CBDA) showed a similar time course profile but lower concentrations due to the fact that vaporization partly decarboxylated these compounds. All THC and CBD metabolites showed a later onset with respect to the parent compounds in the absorption phase and a slower decrease to baseline. In agreement with serum kinetics, THC-COOH-GLUC and 7-COOH-CBD were the significantly most excreted THC and CBD metabolites. The administration of vaporized medical cannabis induced prototypical effects associated with the administration of cannabis or THC in humans, with a kinetic trend overlapping that of parent compounds and metabolites in serum. The pharmacokinetics of cannabinoids, their precursors, and their metabolites in biological fluids of individuals treated with vaporized medical cannabis preparations showed a high interindividual variability as in the case of oral medical cannabis decoction and oil. Inhaled medical cannabis was absorbed into the organism earlier than decoction and oil. Cannabinoids reached higher systemic concentrations, also due to the fact that the acid precursors decarboxylated to parent cannabinoids at high temperatures, and consequently, the physiological and subjective effects occurred earlier and resulted with higher intensity. No serious adverse effects were observed

    Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantifying Fentanyl and 22 Analogs and Metabolites in Whole Blood, Urine, and Hair

    Get PDF
    Recently, synthetic opioid-related overdose fatalities, led by illicitly manufactured fentanyl and analogs, increased at an alarming rate, posing a global public health threat. New synthetic fentanyl analogs have been constantly emerging onto the drug marked for the last few years, to circumvent the laws and avoid analytical detection. Analytical methods need to be regularly updated to keep up with the new trends. In this study, we aimed to develop a new method for detecting the newest fentanyl analogs with a high sensitivity, in whole blood, urine, and hair. The method is intended to provide to clinical and forensic toxicologists a tool for documenting consumption. We developed a comprehensive ultra-high-performance liquid chromatography-tandem mass spectrometry method for quantifying fentanyl and 22 analogs and metabolites. Urine samples were simply diluted before injection; a liquid-liquid extraction was performed for blood testing; and a solid phase extraction was performed in hair. The chromatographic separation was short (8 min). The method was validated with a high sensitivity; limits of quantifications ranged from 2 to 6 ng/L in blood and urine, and from 11 to 21 pg/g in hair. The suitability of the method was tested with 42 postmortem blood, urine, or hair specimens from 27 fatalities in which fentanyl analogs were involved. Average blood concentrations (±SD) were 7.84 ± 7.21 and 30.0 ± 18.0 μg/L for cyclopropylfentanyl and cyclopropyl norfentanyl, respectively (n = 8), 4.08 ± 2.30 μg/L for methoxyacetylfentanyl, (n = 4), 40.2 ± 38.6 and 44.5 ± 21.1 μg/L for acetylfentanyl and acetyl norfentanyl, respectively (n = 3), 33.7 and 7.17 μg/L for fentanyl and norfentanyl, respectively (n = 1), 3.60 and 0.90 μg/L for furanylfentanyl and furanyl norfentanyl, respectively (n = 1), 0.67 μg/L for sufentanil (n = 1), and 3.13 ± 2.37 μg/L for 4-ANPP (n = 9). Average urine concentrations were 47.7 ± 39.3 and 417 ± 296 μg/L for cyclopropylfentanyl and cyclopropyl norfentanyl, respectively (n = 11), 995 ± 908 μg/L for methoxyacetylfentanyl, (n = 3), 1,874 ± 1,710 and 6,582 ± 3,252 μg/L for acetylfentanyl and acetyl norfentanyl, respectively (n = 5), 146 ± 318 and 300 ± 710 μg/L for fentanyl (n = 5) and norfentanyl (n = 6), respectively, 84.0 and 23.0 μg/L for furanylfentanyl and furanyl norfentanyl, respectively (n = 1), and 50.5 ± 50.9 μg/L for 4-ANPP (n = 10). Average hair concentrations were 2,670 ± 184 and 82.1 ± 94.7 ng/g for fentanyl and norfentanyl, respectively (n = 2), and 10.8 ± 0.57 ng/g for 4-ANPP (n = 2)

    Disposition of Cannabidiol Metabolites in Serum and Urine from Healthy Individuals Treated with Pharmaceutical Preparations of Medical Cannabis

    Get PDF
    The use of cannabis flowering tops with standardized amounts of active phytocannabinoids was recently authorized in several countries to treat several painful pathological conditions. The acute pharmacological effects and disposition of Δ-9-tetrahydrocannabinol (THC), cannabidiol (CBD), their acidic precursors and THC metabolites after oil and decoction administration have been already described. In this study, the disposition of CBD metabolites: 7-carboxy-cannabidiol (7-COOH-CBD), 7-hydroxycannabidiol (7-OH-CBD), 6-α-hydroxycannabidiol (6-α-OH-CBD), and 6-β-hydroxycannabidiol (6-β-OH-CBD) in the serum and urine of healthy volunteers was presented. Thirteen healthy volunteers were administered 100 mL of cannabis decoction in the first experimental session and, after 15 days of washout, 0.45 mL of oil. Serum and urine samples were collected at different time points, and the CBD metabolites were quantified by ultra-high-performance liquid chromatography-tandem mass spectrometry. The most abundant serum metabolite was 7-COOH-CBD, followed by 7-OH-CBD, 6-β-OH-CBD, and6-α-OH-CBD, after decoction and oil. Both 7-OH-CBD and the 6-α-OH-CBD showed similar pharmacokinetic properties following administration of both cannabis preparations, whereas 7-COOH and 6-α-OH-CBD displayed a significant higher bioavailability after decoction consumption. All CBD metabolites were similarly excreted after oil and decoction intake apart from 6-α-OH-CBD, which had a significantly lower excretion after oil administration. The pharmacokinetic characterization of CBD metabolites is crucial for clinical practice since the cannabis herbal preparations are increasingly used for several pathological conditions

    Consensus care recommendations for alfapump® in cirrhotic patients with refractory or recurrent ascites.

    Get PDF
    BACKGROUND The alfapump® is an implantable class III medical device that pumps ascitic fluid from the peritoneal space to the urinary bladder from where it is excreted. The pump reduces or abrogates the need for repeated paracentesis in patients with recurrent or refractory ascites. AIMS To improve outcomes for alfapump® implantation and pre- and post-implant patient management in both clinical trial and real-world settings by development of consensus recommendations. METHODS The alfapump® working group consisting of hepatologists and surgeons with extensive experience in implantation of the alfapump® and patient management met on two occasions: (1) to determine the key areas where recommendations should be made; and (2) to discuss the experiences of the working group within those areas and formulate draft statements. Developed statements were submitted to the group and consensus sought on relevance and wording through a collaborative iterative approach in order to consolidate the recommendations into consensus statements. Only recommendations agreed upon unanimously were included. RESULTS Twenty-three consensus recommendations were developed in the areas of pre-implantation procedure, (three statements), surgical implant procedure (11 statements), immediate post-implant care (three statements) and long-term management (six statements). CONCLUSIONS The consensus statements are a valuable reference resource for physicians managing patients with the alfapump® and for those considering management strategies for patients with refractory ascites
    corecore