403 research outputs found

    User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias.

    Get PDF
    BackgroundData obtained during arrhythmia is retained in real-time cardiovascular magnetic resonance (rt-CMR), but there is limited and inconsistent evidence to show that rt-CMR can accurately assess beat-to-beat variation in left ventricular (LV) function or during an arrhythmia.MethodsMulti-slice, short axis cine and real-time golden-angle radial CMR data was collected in 22 clinical patients (18 in sinus rhythm and 4 patients with arrhythmia). A user-initialized active contour segmentation (ACS) software was validated via comparison to manual segmentation on clinically accepted software. For each image in the 2D acquisitions, slice volume was calculated and global LV volumes were estimated via summation across the LV using multiple slices. Real-time imaging data was reconstructed using different image exposure times and frame rates to evaluate the effect of temporal resolution on measured function in each slice via ACS. Finally, global volumetric function of ectopic and non-ectopic beats was measured using ACS in patients with arrhythmias.ResultsACS provides global LV volume measurements that are not significantly different from manual quantification of retrospectively gated cine images in sinus rhythm patients. With an exposure time of 95.2 ms and a frame rate of > 89 frames per second, golden-angle real-time imaging accurately captures hemodynamic function over a range of patient heart rates. In four patients with frequent ectopic contractions, initial quantification of the impact of ectopic beats on hemodynamic function was demonstrated.ConclusionUser-initialized active contours and golden-angle real-time radial CMR can be used to determine time-varying LV function in patients. These methods will be very useful for the assessment of LV function in patients with frequent arrhythmias

    Collaborative design of assessment criteria to improve undergraduate student engagement and performance

    Get PDF
    Student engagement is vital in enhancing the student experience and encouraging deeper learning. Involving students in the design of assessment criteria is one way in which to increase student engagement. In 2011, a marking matrix was used at Aston University (UK) for logbook assessment (Group One) in a project-based learning module. The next cohort of students in 2012 (Group Two) were asked to collaboratively redesign the matrix and were given a questionnaire about the exercise. Group Two initially scored a lower average logbook mark than Group One. However, Group Two showed the greatest improvement between assessments, and the quality of, and commitment to, logbooks was noticeably improved. Student input resulted in a more defined, tougher mark scheme. However, this provided an improved feedback system that gave more scope for self-improvement. The majority of students found the exercise incorporated their ideas, enhanced their understanding, and was useful in itself

    In-vivo heterogeneous functional and residual strains in human aortic valve leaflets

    Get PDF
    Residual and physiological functional strains in soft tissues are known to play an important role in modulating organ stress distributions. Yet, no known comprehensive information on residual strains exist, or non-invasive techniques to quantify in-vivo deformations for the aortic valve (AV) leaflets. Herein we present a completely non-invasive approach for determining heterogeneous strains – both functional and residual – in semilunar valves and apply it to normal human AV leaflets. Transesophageal 3D echocardiographic (3DE) images of the AV were acquired from open-heart transplant patients, with each AV leaflet excised after heart explant and then imaged in a flattened configuration ex-vivo. Using an established spline parameterization of both 3DE segmentations and digitized ex-vivo images (Aggarwal et al., 2014), surface strains were calculated for deformation between the ex-vivo and three in-vivo configurations: fully open, just-coapted, and fully-loaded. Results indicated that leaflet area increased by an average of 20% from the ex-vivo to in-vivo open states, with a highly heterogeneous strain field. The increase in area from open to just-coapted state was the highest at an average of 25%, while that from just-coapted to fully-loaded remained almost unaltered. Going from the ex-vivo to in-vivo mid-systole configurations, the leaflet area near the basal attachment shrank slightly, whereas the free edge expanded by ~10%. This was accompanied by a 10° −20° shear along the circumferential-radial direction. Moreover, the principal stretches aligned approximately with the circumferential and radial directions for all cases, with the highest stretch being along the radial direction. Collectively, these results indicated that even though the AV did not support any measurable pressure gradient in the just-coapted state, the leaflets were significantly pre-strained with respect to the excised state. Furthermore, the collagen fibers of the leaflet were almost fully recruited in the just-coapted state, making the leaflet very stiff with marginal deformation under full pressure. Lastly, the deformation was always higher in the radial direction and lower along the circumferential one, the latter direction made stiffer by the preferential alignment of collagen fibers. These results provide significant insight into the distribution of residual strains and the in-vivo strains encountered during valve opening and closing in AV leaflets, and will form an important component of the tool that can evaluate valve׳s functional properties in a non-invasive manner

    Multimodal image analysis and subvalvular dynamics in ischemic mitral regurgitation

    Get PDF
    Background: The exact geometric pathogenesis of leaflet tethering in ischemic mitral regurgitation (IMR) and the relative contribution of each component of the mitral valve complex (MVC) remain largely unknown. In this study, we sought to further elucidate mitral valve (MV) leaflet remodeling and papillary muscle dynamics in an ovine model of IMR with magnetic resonance imaging (MRI) and 3-dimensional echocardiography (3DE). Methods: Multimodal imaging combining 3DE and MRI was used to analyze the MVC at baseline, 30 minutes post–myocardial infarction (MI), and 12 weeks post-MI in ovine IMR models. Advanced 3D imaging software was used to trace the MVC from each modality, and the tracings were verified against resected specimens. Results: 3DE MV remodeling was regionally heterogenous and observed primarily in the anterior leaflet, with significant increases in surface area, especially in A2 and A3. The posterior leaflet was significantly shortened in P2 and P3. Mean posteromedial papillary muscle (PMPM) volume was decreased from 1.9 ± 0.2 cm3 at baseline to 0.9 ± 0.3 cm3 at 12 weeks post-MI (P <.05). At 12 weeks post-MI, the PMPM was predominately displaced horizontally and outward along the intercommissural axis with minor apical displacement. The subvalvular contribution to tethering is a combination of unilateral movement, outward displacement, and degeneration of the PMPM. These findings have led to a proposed new framework for characterizing PMPM dynamics in IMR. Conclusions: This study provides new insights into the complex interrelated and regionally heterogenous valvular and subvalvular mechanisms involved in the geometric pathogenesis of IMR tethering

    Multi-Scale Imaging and Informatics Pipeline for In Situ Pluripotent Stem Cell Analysis

    Get PDF
    Human pluripotent stem (hPS) cells are a potential source of cells for medical therapy and an ideal system to study fate decisions in early development. However, hPS cells cultured in vitro exhibit a high degree of heterogeneity, presenting an obstacle to clinical translation. hPS cells grow in spatially patterned colony structures, necessitating quantitative single-cell image analysis. We offer a tool for analyzing the spatial population context of hPS cells that integrates automated fluorescent microscopy with an analysis pipeline. It enables high-throughput detection of colonies at low resolution, with single-cellular and sub-cellular analysis at high resolutions, generating seamless in situ maps of single-cellular data organized by colony. We demonstrate the tool's utility by analyzing inter- and intra-colony heterogeneity of hPS cell cycle regulation and pluripotency marker expression. We measured the heterogeneity within individual colonies by analyzing cell cycle as a function of distance. Cells loosely associated with the outside of the colony are more likely to be in G1, reflecting a less pluripotent state, while cells within the first pluripotent layer are more likely to be in G2, possibly reflecting a G2/M block. Our multi-scale analysis tool groups colony regions into density classes, and cells belonging to those classes have distinct distributions of pluripotency markers and respond differently to DNA damage induction. Lastly, we demonstrate that our pipeline can robustly handle high-content, high-resolution single molecular mRNA FISH data by using novel image processing techniques. Overall, the imaging informatics pipeline presented offers a novel approach to the analysis of hPS cells that includes not only single cell features but also colony wide, and more generally, multi-scale spatial configuration

    Quantitative three-dimensional echocardiographic analysis of the bicuspid aortic valve and aortic root:A single modality approach

    Get PDF
    Background Patients with bicuspid aortic valves (BAV) are heterogeneous with regard to patterns of root remodeling and valvular dysfunction. Two-dimensional echocardiography is the standard surveillance modality for patients with aortic valve dysfunction. However, ancillary computed tomography or magnetic resonance imaging is often necessary to characterize associated patterns of aortic root pathology. Conversely, the pairing of three-dimensional (3D) echocardiography with novel quantitative modeling techniques allows for a single modality description of the entire root complex. We sought to determine 3D aortic valve and root geometry with this quantitative approach. Methods Transesophageal real-time 3D echocardiography was performed in five patients with tricuspid aortic valves (TAV) and in five patients with BAV. No patient had evidence of valvular dysfunction or aortic root pathology. A customized image analysis protocol was used to assess 3D aortic annular, valvular, and root geometry. Results Annular, sinus and sinotubular junction diameters and areas were similar in both groups. Coaptation length and area were higher in the TAV group (7.25 +/- 0.98 mm and 298 +/- 118 mm(2), respectively) compared to the BAV group (5.67 +/- 1.33 mm and 177 +/- 43 mm(2); P = .07 and P = .01). Cusp surface area to annular area, coaptation height, and the sub- and supravalvular tenting indices did not differ significantly between groups. Conclusions Single modality 3D echocardiography-based modeling allows for a quantitative description of the aortic valve and root geometry. This technique together with novel indices will improve our understanding of normal and pathologic geometry in the BAV population and may help to identify geometric predictors of adverse remodeling and guide tailored surgical therapy

    Convective Fingering of an Autocatalytic Reaction Front

    Full text link
    We report experimental observations of the convection-driven fingering instability of an iodate-arsenous acid chemical reaction front. The front propagated upward in a vertical slab; the thickness of the slab was varied to control the degree of instability. We observed the onset and subsequent nonlinear evolution of the fingers, which were made visible by a {\it p}H indicator. We measured the spacing of the fingers during their initial stages and compared this to the wavelength of the fastest growing linear mode predicted by the stability analysis of Huang {\it et. al.} [{\it Phys. Rev. E}, {\bf 48}, 4378 (1993), and unpublished]. We find agreement with the thickness dependence predicted by the theory.Comment: 11 pages, RevTex with 3 eps figures. To be published in Phys Rev E, [email protected], [email protected], [email protected]

    Screening and brief interventions for hazardous and harmful alcohol use in primary care: a cluster randomised controlled trial protocol

    Get PDF
    A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However,although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlledtrial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Ninety-six OMs from 9 probation areas across 3 English regions (the NorthEast Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will berandomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brieflifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) orthe Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months postintervention. Analysis will include client measures (screening result, weekly alcohol consumption,alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors associated with successful implementation.The trial will evaluate the impact of screening and brief alcohol intervention in routine probation work and therefore its findings will be highly relevant to probation teams and thus the criminal justice system in the UK

    ACC/AHA Special Report: Clinical Practice Guideline Implementation Strategies: A Summary of Systematic Reviews by the NHLBI Implementation Science Work Group: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines

    Get PDF
    BACKGROUND: In 2008, the National Heart, Lung, and Blood Institute convened an Implementation Science Work Group to assess evidence-based strategies for effectively implementing clinical practice guidelines. This was part of a larger effort to update existing clinical practice guidelines on cholesterol, blood pressure, and overweight/obesity. OBJECTIVES: Review evidence from the published implementation science literature and identify effective or promising strategies to enhance the adoption and implementation of clinical practice guidelines. METHODS: This systematic review was conducted on 4 critical questions, each focusing on the adoption and effectiveness of 4 intervention strategies: (1) reminders, (2) educational outreach visits, (3) audit and feedback, and (4) provider incentives. A scoping review of the Rx for Change database of systematic reviews was used to identify promising guideline implementation interventions aimed at providers. Inclusion and exclusion criteria were developed a priori for each question, and the published literature was initially searched up to 2012, and then updated with a supplemental search to 2015. Two independent reviewers screened the returned citations to identify relevant reviews and rated the quality of each included review. RESULTS: Audit and feedback and educational outreach visits were generally effective in improving both process of care (15 of 21 reviews and 12 of 13 reviews, respectively) and clinical outcomes (7 of 12 reviews and 3 of 5 reviews, respectively). Provider incentives showed mixed effectiveness for improving both process of care (3 of 4 reviews) and clinical outcomes (3 reviews equally distributed between generally effective, mixed, and generally ineffective). Reminders showed mixed effectiveness for improving process of care outcomes (27 reviews with 11 mixed and 3 generally ineffective results) and were generally ineffective for clinical outcomes (18 reviews with 6 mixed and 9 generally ineffective results). Educational outreach visits (2 of 2 reviews), reminders (3 of 4 reviews), and provider incentives (1 of 1 review) were generally effective for cost reduction. Educational outreach visits (1 of 1 review) and provider incentives (1 of 1 review) were also generally effective for cost-effectiveness outcomes. Barriers to clinician adoption or adherence to guidelines included time constraints (8 reviews/overviews); limited staffing resources (2 overviews); timing (5 reviews/overviews); clinician skepticism (5 reviews/overviews); clinician knowledge of guidelines (4 reviews/overviews); and higher age of the clinician (1 overview). Facilitating factors included guideline characteristics such as format, resources, and end-user involvement (6 reviews/overviews); involving stakeholders (5 reviews/overviews); leadership support (5 reviews/overviews); scope of implementation (5 reviews/overviews); organizational culture such as multidisciplinary teams and low-baseline adherence (9 reviews/overviews); and electronic guidelines systems (3 reviews). CONCLUSION: The strategies of audit and feedback and educational outreach visits were generally effective in improving both process of care and clinical outcomes. Reminders and provider incentives showed mixed effectiveness, or were generally ineffective. No general conclusion could be reached about cost effectiveness, because of limitations in the evidence. Important gaps exist in the evidence on effectiveness of implementation interventions, especially regarding clinical outcomes, cost effectiveness and contextual issues affecting successful implementation
    • …
    corecore