19 research outputs found

    Suppressing bladder artifacts in bone SPECT of the pelvis.

    Get PDF
    OBJECTIVE: Bladder-filling reconstruction artifacts have a detrimental effect on the image quality of pelvic bone single photon emission computed tomography (SPECT). Using a simple protocol consisting of forced diuresis coupled with intravenous (IV) hydration, this study was undertaken to obtain an artifact-free pelvic SPECT after discarding the residual urinary activity. METHODS: Thirty patients were enrolled. In group I, pelvic SPECT was performed directly after normal void, whereas in group II, SPECT was preceded by IV injection of 0.5 mg/kg furosemide (maximum 40 mg) coupled with IV infusion of 500 cc of physiologic saline. Bladder-filling reconstruction artifacts were analyzed in group I patients, who had their images reconstructed using both filtered backprojection and iterative algorithms, both qualitatively and quantitatively by means of regions of interest (ROIs) drawn around the artifact-bearing bone areas as well as the corresponding contralateral sites. For group II patients, besides visual analysis, ROIs were placed over the sites corresponding to those of the group I patients. In every patient, total counts of each ROI were normalized to a reference ROI placed over the sacrum, and a ratio was created. RESULTS: Using filtered backprojection, two forms of artifacts were identified in group I patients: first, a streak pattern that extended to the sacro-iliac joint in nine (60%) patients, the hip joint in five (33%), the superior pubic rami in four (27%), the sacrum in three (20%), and the ischium in one (6%); second, a count loss subtype which extended to the hip joints in nine (60%) patients. Corresponding values after iterative reconstruction were two (13%) for the sacro-iliac joint, three (20%) for the hip joint, one (6%) for the superior pubic ramus, and one (6%) for the sacrum. In five (33%) patients, residual count loss artifacts were still identifiable after iterative reconstruction. However in group II, no such effects were observed because the bladder activity reached near background level in 14 (93%) of 15 patients after three successive voids with a 3.5-fold decrease in the mean value of total bladder count in comparison with group I patients. A statistically significant difference was found between artifact- and non-artifact-harboring ROIs in group I whichever the method used for reconstruction, whereas the values of right and left hemi-pelvis ROIs/sacrum in group II were almost identical. CONCLUSIONS: Forced diuresis coupled with parenteral hydration facilitates the acquisition of an artifact-free pelvic SPECT. Especially for clinical questions that focus on femoral heads and pubic bones, applying the aforementioned protocol may improve the diagnostic accuracy of pelvic bone SPECT

    Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water

    Get PDF
    PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine

    Added prognostic value of myocardial blood flow quantitation in rubidium-82 positron emission tomography imaging

    Full text link
    AIMS: We studied the respective added value of the quantitative myocardial blood flow (MBF) and the myocardial flow reserve (MFR) as assessed with (82)Rb positron emission tomography (PET)/CT in predicting major adverse cardiovascular events (MACEs) in patients with suspected myocardial ischaemia. METHODS AND RESULTS: Myocardial perfusion images were analysed semi-quantitatively (SDS, summed difference score) and quantitatively (MBF, MFR) in 351 patients. Follow-up was completed in 335 patients and annualized MACE (cardiac death, myocardial infarction, revascularization, or hospitalization for congestive heart failure or de novo stable angor) rates were analysed with the Kaplan-Meier method in 318 patients after excluding 17 patients with early revascularizations (2) (n = 105) than those without [14% (95% CI = 9.1-22%) vs. 4.5% (2.7-7.4%), P < 0.0001]. The lowest MFR tertile group (MFR <1.8) had the highest MACE rate [16% (11-25%) vs. 2.9% (1.2-7.0%) and 4.3% (2.1-9.0%), P < 0.0001]. Similarly, the lowest stress MBF tertile group (MBF <1.8 mL/min/g) had the highest MACE rate [14% (9.2-22%) vs. 7.3% (4.2-13%) and 1.8% (0.6-5.5%), P = 0.0005]. Quantitation with stress MBF or MFR had a significant independent prognostic power in addition to semi-quantitative findings. The largest added value was conferred by combining stress MBF to SDS. This holds true even for patients without ischaemia. CONCLUSION: Perfusion findings in (82)Rb PET/CT are strong MACE outcome predictors. MBF quantification has an added value allowing further risk stratification in patients with normal and abnormal perfusion images

    Appropriate use criteria for dementia amyloid imaging in Switzerland – mini-review and statement on behalf of the Swiss Society of Nuclear Medicine and the Swiss Memory Clinics

    No full text
    While FDG-PET imaging of the brain for the differential diagnosis of dementia has been covered by the compulsory health insurance in Switzerland for more than a decade, beta-amyloid-PET just recently has been added to the catalogue of procedures that have been cleared for routine use, provided that a set of appropriate use criteria (AUC) be followed. To provide guidance to dementia care practitioners, the Swiss Society of Nuclear Medicine and the Swiss Memory Clinics jointly report a mini-review on beta-amyloid-PET and discuss the AUC set into effect by the Swiss Federal Office of Public Health, as well as their application and limitations.Die Beta-Amyloid-PET-Bildgebung des Gehirns ist mit der Zulassung für die klinische Routineanwendung durch Swissmedic von 3 EU-weit bereits länger kommerziell verfügbaren Amyloid-β-PET-Radiopharmaka nun auch in dem Nicht-EU-Land Schweiz allgemein verfügbar geworden. Seit dem 01.04.2020 unterliegt die Anwendung von Beta-Amyloid-PET der gesetzlichen Leistungspflicht durch die obligatorische Schweizer Krankenversicherung für die Differenzialdiagnose demenzieller Erkrankungen unter bestimmten Voraussetzungen.Im Namen der Schweizer Gesellschaft für Nuklearmedizin (SGNM) und der Schweizer Memory-Kliniken publiziert die AG Neuronuklearmedizin der SGNM die aktuell gültigen Anwendungskriterien im Rahmen der gesetzlichen Leistungspflicht in der Schweiz, um sowohl den verordnenden Demenzspezialisten, Gerontopsychiatern und Neurologen, als auch den durchführenden Nuklearmedizinern Handlungsempfehlung an die Hand zu geben und einen aktuellen Kurzüberblick über Möglichkeiten und Grenzen der Beta-Amyloid-Bildgebung im klinischen Alltagskontext zu geben

    Assessment of coronary vasoreactivity by multidetector computed tomography: feasibility study with rubidium-82 cardiac positron emission tomography.

    No full text
    Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P&gt;0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment

    Prevalence of physiological uptake in the pancreas on somatostatin receptor-based PET/CT: a systematic review and a meta-analysis

    No full text
    Background: Physiological focal radiopharmaceutical uptake in the head and uncinate process of the pancreas may be seen on somatostatin receptor-based PET/CT and might lead to false-positive results for neuroendocrine tumours (NETs). We aimed to perform a systematic review and a meta-analysis about the prevalence of this finding. Methods: We performed a comprehensive computer literature search across several databases until July 2020. Pooled prevalence of physiological focal uptake on somatostatin receptor-based PET/CT in the pancreas was calculated on a per-examination- based analysis and 95% confidence interval values (95% CI) were reported. Results: Six studies (684 patients and 829 PET/CT scans) were included. The pooled prevalence of physiological uptake in the head and uncinate process of the pancreas on somatostatin receptor-based PET/CT imaging was 34% (95% CI 19.5–48.7%) with average SUVmax values ranging from 5 to 12.6. Heterogeneity was seen across the selected studies. Conclusions: High radiopharmaceutical uptake in the head and uncinate process of the pancreas is frequent at somatostatin receptor-based PET/CT and it should be recognized by nuclear medicine physicians to prevent unnecessary additional investigations. In addition, next generation PET/CT tomographs might increase the prevalence of this finding
    corecore