47 research outputs found

    Noninfectious sternal wound inflammation after coronary artery bypass grafting in a patient with myelodysplastic syndrome: A no‐touch approach

    Get PDF
    Pyoderma gangrenosum (PG) is a rare, chronic inflammatory noninfectious dermatosis. It is associated with underlying systemic or hematological diseases such as myelodysplastic syndrome (MDS) and can be triggered after surgery. Recognition and diagnosis of PG can be difficult as it can mimic a wound infection. Misdiagnosis could lead to invasive procedures which worsen the disease and have possible disastrous aftermath. A 74‐year‐old male with a history of MDS presents with an atypical sternal wound inflammation. Diagnosis confirmed PG after skin biopsy. No surgical or invasive procedures were performed and the patient was treated on an outpatient basis with prednisolone, clobetasol cream, and cyclosporine. This case shows the importance of a rapid diagnosis of the disease. Awareness is required for the diagnosis of PG in a wound with pronounced livid borders, without improvement after antibiotic treatment or worsening after debridement. Rapid diagnosis and treatment reduce high healthcare costs, morbidity, and mortality

    Pressure and Flow Properties of Cannulae for Extracorporeal Membrane Oxygenation II: Drainage (Venous) Cannulae

    Get PDF
    The use of extracorporeal life support devices such as extracorporeal membrane oxygenation in adults requires cannulation of the patient's vessels with comparatively large diameter cannulae to allow circulation of large volumes of blood (>5 L/min). The cannula diameter and length are the major determinants for extracorporeal membrane oxygenation flow. Manufacturing companies present pressure-flow charts for the cannulae; however, these tests are performed with water. Aims of this study were 1. to investigate the specified pressure-flow charts obtained when using human blood as the circulating medium and 2. to support extracorporeal membrane oxygenation providers with pressure-flow data for correct choice of the cannula to reach an optimal flow with optimal hydrodynamic performance. Eighteen extracorporeal membrane oxygenation drainage cannulae, donated by the manufacturers (n = 6), were studied in a centrifugal pump driven mock loop. Pressure-flow properties and cannula features were described. The results showed that when blood with a hematocrit of 27% was used, the drainage pressure was consistently higher for a given flow (range 10%-350%) than when water was used (data from each respective manufacturer's product information). It is concluded that the information provided by manufacturers in line with regulatory guidelines does not correspond to clinical performance and therefore may not provide the best guidance for clinicians.info:eu-repo/semantics/publishedVersio

    JavaCyte, a novel open-source tool for automated quantification of key hallmarks of cardiac structural remodeling

    Get PDF
    Many cardiac pathologies involve changes in tissue structure. Conventional analysis of structural features is extremely time-consuming and subject to observer bias. The possibility to determine spatial interrelations between these features is often not fully exploited. We developed a staining protocol and an ImageJ-based tool (JavaCyte) for automated histological analysis of cardiac structure, including quantification of cardiomyocyte size, overall and endomysial fibrosis, spatial patterns of endomysial fibrosis, fibroblast density, capillary density and capillary size. This automated analysis was compared to manual quantification in several well-characterized goat models of atrial fibrillation (AF). In addition, we tested inter-observer variability in atrial biopsies from the CATCH-ME consortium atrial tissue bank, with patients stratified by their cardiovascular risk profile for structural remodeling. We were able to reproduce previous manually derived histological findings in goat models for AF and AV block (AVB) using JavaCyte. Furthermore, strong correlation was found between manual and automated observations for myocyte count (r = 0.94, p < 0.001), myocyte diameter (r = 0.97, p < 0.001), endomysial fibrosis (r = 0.98, p < 0.001) and capillary count (r = 0.95, p < 0.001) in human biopsies. No significant variation between observers was observed (ICC = 0.89, p < 0.001). We developed and validated an open-source tool for high-throughput, automated histological analysis of cardiac tissue properties. JavaCyte was as accurate as manual measurements, with less inter-observer variability and faster throughput

    Clinical and electrophysiological predictors of device-detected new-onset atrial fibrillation during 3 years after cardiac surgery

    Get PDF
    Postoperative atrial fibrillation (POAF) after cardiac surgery is an independent predictor of stroke and mortality late after discharge. We aimed to determine the burden and predictors of early (up to 5th postoperative day) and late (after 5th postoperative day) new-onset atrial fibrillation (AF) using implantable loop recorders (ILRs) in patients undergoing open chest cardiac surgery Seventy-nine patients without a history of AF undergoing cardiac surgery underwent peri-operative high-resolution mapping of electrically induced AF and were followed 36 months after surgery using an ILR (Reveal XTTM). Clinical and electrophysiological predictors of late POAF were assessed. POAF occurred in 46 patients (58%), with early POAF detected in 27 (34%) and late POAF in 37 patients (47%). Late POAF episodes were short-lasting (mostly between 2 min and 6 h) and showed a circadian rhythm pattern with a peak of episode initiation during daytime. In POAF patients, electrically induced AF showed more complex propagation patterns than in patients without POAF. Early POAF, right atrial (RA) volume, prolonged PR time, and advanced age were independent predictors of late POAF

    Infective endocarditis in the Netherlands:current epidemiological profile and mortality An analysis based on partial ESC EORP collected data

    Get PDF
    Introduction: Infective endocarditis (IE) is associated with a high in-hospital and long term mortality. Although progress has been made in diagnostic approach and management of IE, morbidity and mortality of IE remain high. In the latest European guidelines, the importance of the multi-modality imaging in diagnosis and follow up of IE is emphasized. Aim: The aim was to provide information regarding mortality and adverse events of IE, to determine IE characteristics and to assess current use of imaging in the diagnostic workup of IE. Methods: This is a prospective observational cohort study. We used data from the EURO-ENDO registry. Seven hospitals in the Netherlands have participated and included patients with IE between April 2016 and April 2018. Results: A total of 139 IE patients were included. Prosthetic valve endocarditis constituted 32.4% of the cases, cardiac device related IE 7.2% and aortic root prosthesis IE 3.6%. In-hospital mortality was 14.4% (20 patients) and one-year mortality was 21.6% (30 patients). The incidence of embolic events under treatment was 16.5%, while congestive heart failure or cardiogenic shock occurred in 15.1% of the patients. Transthoracic and transoesophageal echocardiography were performed most frequently (97.8%; 81.3%) and within 3 days after IE suspicion, followed by 18F‑fluorodeoxyglucose positron emission tomography/computed tomography (45.3%) within 6 days and multi-slice computed tomography (42.4%) within 7 days. Conclusion: We observed a high percentage of prosthetic valve endocarditis, rapid and extensive use of imaging and a relatively low in-hospital and one-year mortality of IE in the Netherlands. Limitations include possible selection bias

    Pressure and Flow Properties of Cannulae for Extracorporeal Membrane Oxygenation I: Return (Arterial) Cannulae

    Get PDF
    Adequate extracorporeal membrane oxygenation support in the adult requires cannulae permitting blood flows up to 6-8 L/minute. In accordance with Poiseuille's law, flow is proportional to the fourth power of cannula inner diameter and inversely proportional to its length. Poiseuille's law can be applied to obtain the pressure drop of an incompressible, Newtonian fluid (such as water) flowing in a cylindrical tube. However, as blood is a pseudoplastic non-Newtonian fluid, the validity of Poiseuille's law is questionable for prediction of cannula properties in clinical practice. Pressure-flow charts with non-Newtonian fluids, such as blood, are typically not provided by the manufacturers. A standardized laboratory test of return (arterial) cannulae for extracorporeal membrane oxygenation was performed. The aim was to determine pressure-flow data with human whole blood in addition to manufacturers' water tests to facilitate an appropriate choice of cannula for the desired flow range. In total, 14 cannulae from three manufacturers were tested. Data concerning design, characteristics, and performance were graphically presented for each tested cannula. Measured blood flows were in most cases 3-21% lower than those provided by manufacturers. This was most pronounced in the narrow cannulae (15-17 Fr) where the reduction ranged from 27% to 40% at low flows and 5-15% in the upper flow range. These differences were less apparent with increasing cannula diameter. There was a marked disparity between manufacturers. Based on the measured results, testing of cannulae including whole blood flows in a standardized bench test would be recommended.info:eu-repo/semantics/publishedVersio

    Normal-hearing listeners' and cochlear implant users' perception of pitch cues in emotional speech

    No full text
    In cochlear implants (CIs), acoustic speech cues, especially for pitch, are delivered in a degraded form. This study's aim is to assess whether due to degraded pitch cues, normal-hearing listeners and CI users employ different perceptual strategies to recognize vocal emotions, and, if so, how these differ. Voice actors were recorded pronouncing a nonce word in four different emotions: anger, sadness, joy, and relief. These recordings' pitch cues were phonetically analyzed. The recordings were used to test 20 normal-hearing listeners' and 20 CI users' emotion recognition. In congruence with previous studies, high-arousal emotions had a higher mean pitch, wider pitch range, and more dominant pitches than low-arousal emotions. Regarding pitch, speakers did not differentiate emotions based on valence but on arousal. Normal-hearing listeners outperformed CI users in emotion recognition, even when presented with CI simulated stimuli. However, only normal-hearing listeners recognized one particular actor's emotions worse than the other actors'. The groups behaved differently when presented with similar input, showing that they had to employ differing strategies. Considering the respective speaker's deviating pronunciation, it appears that for normal-hearing listeners, mean pitch is a more salient cue than pitch range, whereas CI users are biased toward pitch range cue
    corecore