83 research outputs found

    Impact of mammographic screening and advanced cancer definition on the percentage of advanced-stage cancers in a steady-state breast screening programme in the Netherlands

    Get PDF
    Background: To estimate the percentages of advanced-stage breast cancers (BCs) detected during the course of a steady-state screening programme when using different definitions of advanced BC. Methods: Data of women aged 49–74 years, diagnosed with BC in 2006–2015, were selected from the Netherlands Cancer Registry and linked to the screening registry. BCs were classified as screen-detected, interval or non-screened. Three definitions of advanced BC were used for comparison: TNM stage (III–IV), NM stage (N+ and/or M+) and T size (invasive tumour ≥15 mm). Analyses were performed assuming a 10% overdiagnosis rate. In sensitivity analyses, this assumption varied from 0 to 30%. Results: We included 46,734 screen-detected, 17,362 interval and 24,189 non-screened BCs. By TNM stage, 4.9% of screen-detected BCs were advanced, compared with 19.4% and 22.8% of interval and non-screened BCs, respectively (p < 0.001). Applying the other definitions led to higher percentages of advanced BC being detected. Depending on the definition interval, non-screened BCs had a 2–5-times risk of being advanced. Conclusion: Irrespective of the definition, screen-detected BCs were less frequently in the advanced stage. These findings provide evidence of a stage shift to early detection and support the potential of mammographic screening to reduce treatment-related burdens and the mortality associated with BC

    Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    Get PDF
    Contains fulltext : 89208.pdf (publisher's version ) (Closed access)OBJECTIVES: To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. METHODS: Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. RESULTS: A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p < .001), with a significant increase in cancer detection (p = .010). CONCLUSION: As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection.1 september 201

    Feasibility of noncontact piezoelectric detection of photoacoustic signals in tissue-mimicking phantoms

    Get PDF
    The feasibility of air-coupled ultrasound transducers to detect laser-induced ultrasound from artificial blood vessels embedded in an optically scattering phantom is demonstrated. These air-coupled transducers allow new applications in biomedical photoacoustic imaging where contact with tissue is not preferred. One promising application of such transducers is the addition of photoacoustic imaging to the regular x-ray mammographic screening procedure

    Создание развитых интернет-программ на примере построения виджет-программ

    Get PDF
    Рассмотрено применение методологии создания развитых Интернет-программ на основе Adobe Flex 2.0 с применением паттернов проектирования и архитектурного каркаса. Подход проиллюстрирован построением виджет-программ

    Using computer-aided detection in mammography as a decision support

    Get PDF
    Contains fulltext : 87548.pdf (publisher's version ) (Closed access)OBJECTIVE: To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. METHODS: A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. RESULTS: Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 +/- 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 +/- 57.8 s/case). CONCLUSION: Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.1 oktober 201

    Increase in perceived case suspiciousness due to local contrast optimisation in digital screening mammography

    Get PDF
    Item does not contain fulltextOBJECTIVES: To determine the influence of local contrast optimisation on diagnostic accuracy and perceived suspiciousness of digital screening mammograms. METHODS: Data were collected from a screening region in the Netherlands and consisted of 263 digital screening cases (153 recalled,110 normal). Each case was available twice, once processed with a tissue equalisation (TE) algorithm and once with local contrast optimisation (PV). All cases had digitised previous mammograms. For both algorithms, the probability of malignancy of each finding was scored independently by six screening radiologists. Perceived case suspiciousness was defined as the highest probability of malignancy of all findings of a radiologist within a case. Differences in diagnostic accuracy of the processing algorithms were analysed by comparing the areas under the receiver operating characteristic curves (A(z)). Differences in perceived case suspiciousness were analysed using sign tests. RESULTS: There was no significant difference in A(z) (TE: 0.909, PV 0.917, P = 0.46). For all radiologists, perceived case suspiciousness using PV was higher than using TE more often than vice versa (ratio: 1.14-2.12). This was significant (P <0.0083) for four radiologists. CONCLUSIONS: Optimisation of local contrast by image processing may increase perceived case suspiciousness, while diagnostic accuracy may remain similar. KEY POINTS: Variations among different image processing algorithms for digital screening mammography are large. Current algorithms still aim for optimal local contrast with a low dynamic range. Although optimisation of contrast may increase sensitivity, diagnostic accuracy is probably unchanged. Increased local contrast may render both normal and abnormal structures more conspicuous.1 april 201

    Digital radiography of the chest: Reassessment of the high-voltage technique?

    No full text
    corecore