62 research outputs found

    Thermal analysis of the antineutrino 144Ce source calorimeter for the SOX experiment

    Get PDF
    The technical note describes the calorimeter which will be used to measure the activity of the antineutrino 144Ce source of the SOX experiment at the Gran Sasso Laboratories. The principle of the calorimeter is based on the measurement of both mass flow and temperature increase of the water circulating in the heat exchanger surrounding the source. The calorimeter is vacuum insulated in order to minimize the heat losses. The preliminary design and thermal Finite Element Analysis (FEA) are reported in the note

    AD-6 annual report

    No full text
    Annual report AD-6 / AEGI

    Search for geo-neutrinos and rare nuclear processes with Borexino

    No full text
    Borexino was designed to measure solar neutrinos in the MeV or sub-MeV energy range. The unprecedented radiopurity of the detector has allowed the detection of geo-neutrinos and the determination of competitive limits on the rate of rare or forbidden processes. In this paper, we review the basic principle of neutrinos and antineutrinos detection in Borexino and we describe the results of the geo-neutrinos measurements and their implications. Then we summarize the search for Borexino events correlated with gamma ray bursts and for axion induced signals, and the limits achieved on Pauli forbidden transitions and on the electron charge conservation

    The application software for the instrument control unit of the NISP instrument of the Euclid mission: final status and lessons learned after delivery of the flight version

    No full text
    In this paper we describe the final status of the application software (ASW) of the instrument control unit (ICU) of NISP, the Near-Infrared Spectro-Photometer of the Euclid mission, as the version for Flight has been tested and delivered to the industry for the next integration phases. This software is based on a real-time operating system (RTEMS) and will interface with all the subunits of NISP, as well as the command and data management unit (CDMU) of the spacecraft for telecommand and housekeeping management. We will describe in particular the final tests and the main obstacles which had to be faced in order to implement an efficient and reliable interface with all the NISP subsystems

    Recoil Directionality Studies in Two-Phase Liquid Argon TPC Detectors

    No full text
    Projects attempting the direct detection of WIMP dark matter share the common problem of eliminating sources of background or using techniques to distinguish background events from true signals. Although experiments such as DarkSide have achieved essentially background free exposures through careful choice of materials and application of efficient veto techniques, there will still be a high burden of proof to convince the greater scientific community when a discovery is claimed. A directional signature in the data would provide extremely strong evidence to distinguish a true WIMP signal from that of an isotropic background. Two-phase argon time projection chambers (TPCs) provide an experimental apparatus which can both be scaled to the ton-scale size required to accommodate the low cross-section expected for WIMP interactions and have an anisotropy that could be exploited to evaluate the polar angles of the resulting nuclear recoils from WIMP collisions with target nuclei. Our studies show that even a modest resolution in the polar angle reconstruction would offer a powerful tool to detect a directional signature. In this contribution, the status of the ReD experiment, which is under construction at Naples University, will be also shown. The aim of the project is to assess and enhance the directionality of two-phase argon TPCs. ReD will use a small TPC exposed to a beam of mono-energetic neutrons to study the so called “columnar recombination” in liquid argon. This development could have high impact on the future experiments in the field, opening up the potential to find conclusive evidence for dark matter or disprove the WIMP hypothesis at and above the mass range explored by planned accelerator experiments

    Recoil Directionality Studies in Two-Phase Liquid Argon TPC Detectors

    No full text
    Projects attempting the direct detection of WIMP dark matter share the common problem of eliminating sources of background or using techniques to distinguish background events from true signals. Although experiments such as DarkSide have achieved essentially background free exposures through careful choice of materials and application of efficient veto techniques, there will still be a high burden of proof to convince the greater scientific community when a discovery is claimed. A directional signature in the data would provide extremely strong evidence to distinguish a true WIMP signal from that of an isotropic background. Two-phase argon time projection chambers (TPCs) provide an experimental apparatus which can both be scaled to the ton-scale size required to accommodate the low cross-section expected for WIMP interactions and have an anisotropy that could be exploited to evaluate the polar angles of the resulting nuclear recoils from WIMP collisions with target nuclei. Our studies show that even a modest resolution in the polar angle reconstruction would offer a powerful tool to detect a directional signature. In this contribution, the status of the ReD experiment, which is under construction at Naples University, will be also shown. The aim of the project is to assess and enhance the directionality of two-phase argon TPCs. ReD will use a small TPC exposed to a beam of mono-energetic neutrons to study the so called “columnar recombination” in liquid argon. This development could have high impact on the future experiments in the field, opening up the potential to find conclusive evidence for dark matter or disprove the WIMP hypothesis at and above the mass range explored by planned accelerator experiments

    Pulsed production of antihydrogen

    Get PDF
    Antihydrogen atoms with K or sub-K temperature are a powerful tool to precisely probe the validity of fundamental physics laws and the design of highly sensitive experiments needs antihydrogen with controllable and well defined conditions. We present here experimental results on the production of antihydrogen in a pulsed mode in which the time when 90% of the atoms are produced is known with an uncertainty of ~250 ns. The pulsed source is generated by the charge-exchange reaction between Rydberg positronium atoms\u2014produced via the injection of a pulsed positron beam into a nanochanneled Si target, and excited by laser pulses\u2014and antiprotons, trapped, cooled and manipulated in electromagnetic traps. The pulsed production enables the control of the antihydrogen temperature, the tunability of the Rydberg states, their de-excitation by pulsed lasers and the manipulation through electric field gradients. The production of pulsed antihydrogen is a major landmark in the AEgIS experiment to perform direct measurements of the validity of the Weak Equivalence Principle for antimatter
    corecore