13,776 research outputs found

    Doppler measurements of the ionosphere on the occasion of the Apollo-Soyuz test project. Part 2: Inversion of differential and rotating Doppler shifts

    Get PDF
    The preparation of the analytical approach and of the related software used in the inversion of the differential and rotating Doppler data obtained from the ionospheric experiment of the Apollo-Soyuz Test Project (ASTP) is discussed. These data were collected in space-to-space paths (between the ASTP Docking Module (DM) and the Apollo Command Service Module and in space-to-ground paths (between the DM and ground). The Doppler links operated at 162 and 324 MHz and have an accuracy better than 3 MHz over 10-sec integration time. The inversion approach was tested with dummy data obtained with a computer simulation. It was found that a measurement accuracy of 1 to 10% in the value of the horizontal electron density gradient at 221-km altitude can be achieved, in space-to-space paths. For space-to-ground paths near the orbital plane, possible effects of the horizontal gradients on the received differential Doppler shifts were identified. It was possible to reduce the gradient-associated errors in the inversion that leads to the columnar electron content by approximately one-half. Accuracies of 5 to 10% in columnar electron content are achievable, with this gradient-compensation technique

    Analgesic action of acetaminophen in symptomatic osteoarthritis of the knee

    Get PDF
    Objectives. The study was designed to investigate the analgesic effects and mechanisms of acetaminophen (paracetamol) in symptomatic osteoarthritis (OA) of the knee. Methods. Twenty patients with symptomatic OA were randomly allocated to two groups treated with either acetaminophen or rofecoxib for 3 months. Visits and measurements were scheduled upon entry (T0), at month 1 (T1) and at month 3 (T3). The intensity of joint pain was evaluated with a 100-mm visual analogue scale (VAS). The physical function of the affected knee was evaluated with a questionnaire comparable to the Western Ontario McMaster Universities Osteoarthritis Index (WOMAC). Levels of serotonin, substance P (SP) and β-endorphin (BEND) were determined with commercial enzyme-linked immunoassay kits. The expression of κ opioid receptor (KOR) in peripheral mononuclear blood cells (PBMCs) was quantified by real-time PCR. Results. Both acetaminophen and rofecoxib relieved pain considerably but with different kinetics, and affected different biomarkers. Rofecoxib appeared to be more efficient, reducing pain intensity by 56% at T1 (P<0.01), whereas acetaminophen reduced it by only 29%. Physical function improved in both groups by T3. Correlated with the pain relief, acetaminophen significantly reduced plasma BEND levels, whereas rofecoxib did not do so. In both groups plasma SP levels were elevated compared with T0. A reduction in serum serotonin was detected in the rofecoxib group at T1 (P=0.004) but had recovered at T3. No changes in KOR mRNA in PBMCs were observed in either group. Conclusions. There is a correlation between reduction in circulating BEND and OA pain relief in patients treated with acetaminophe

    Analgesic action of acetaminophen in symptomatic osteoarthritis of the knee

    Get PDF
    Objectives. The study was designed to investigate the analgesic effects and mechanisms of acetaminophen (paracetamol) in symptomatic osteoarthritis (OA) of the knee. Methods. Twenty patients with symptomatic OA were randomly allocated to two groups treated with either acetaminophen or rofecoxib for 3 months. Visits and measurements were scheduled upon entry (T0), at month 1 (T1) and at month 3 (T3). The intensity of joint pain was evaluated with a 100-mm visual analogue scale (VAS). The physical function of the affected knee was evaluated with a questionnaire comparable to the Western Ontario McMaster Universities Osteoarthritis Index (WOMAC). Levels of serotonin, substance P (SP) and β-endorphin (BEND) were determined with commercial enzyme-linked immunoassay kits. The expression of κ opioid receptor (KOR) in peripheral mononuclear blood cells (PBMCs) was quantified by real-time PCR. Results. Both acetaminophen and rofecoxib relieved pain considerably but with different kinetics, and affected different biomarkers. Rofecoxib appeared to be more efficient, reducing pain intensity by 56% at T1 (P<0.01), whereas acetaminophen reduced it by only 29%. Physical function improved in both groups by T3. Correlated with the pain relief, acetaminophen significantly reduced plasma BEND levels, whereas rofecoxib did not do so. In both groups plasma SP levels were elevated compared with T0. A reduction in serum serotonin was detected in the rofecoxib group at T1 (P=0.004) but had recovered at T3. No changes in KOR mRNA in PBMCs were observed in either group. Conclusions. There is a correlation between reduction in circulating BEND and OA pain relief in patients treated with acetaminophe

    Effects of electromagnetic fields emitted by GSM phones on working memory: a meta-analysis

    Get PDF
    Background and Objective: Current treatments for Alzheimer's Disease (AD) do not affect the course of the illness and brain stimulation techniques are increasingly promoted as potential therapeutic inter-ventions for AD. This study reviews the effects of electromagnetic field (EMF) exposure versus sham exposure on working memory (WM) performance of healthy human participants. Method: Online literature databases and previous systematic reviews were searched for studies of EMF and WM in participants without reported memory problems. Two thousand eight hundred and fifty seven studies were identified, and 10 studies met the inclusion criteria. An assessment of study quality was completed, and separate, random effects meta-analyses were conducted for each of the three WM tasks included: n-back, substitution and digit span forward. Results: No differences were found between participants exposed to active EMF versus sham conditions in any of the three working memory tasks examined. Conclusion: Results indicate that EMF does not affect WM during the n-back, substitution and digit-span tasks. Future studies should focus on the possible effects of chronic exposure to EMF in older adults with AD using a battery of comparable WM and attention tasks, before EMF can be seriously considered as a potential modulator of WM in AD

    Tip cap for a rotor blade

    Get PDF
    A replaceable tip cap for attachment to the end of a rotor blade is described. The tip cap includes a plurality of walls defining a compartment which, if desired, can be divided into a plurality of subcompartments. The tip cap can include inlet and outlet holes in walls thereof to permit fluid communication of a cooling fluid there through. Abrasive material can be attached with the radially outer wall of the tip cap

    Ariel 6 measurements of ultra-heavy cosmic ray fluxes in the region 34 or = Z or = 48

    Get PDF
    The Ariel VI satellite was launched by NASA on a Scout rocket on 3rd June 1979 from Wallops Island, Virginia, USA, into a near circular 625 km orbit inclined at 55 deg. It carried a spherical cosmic ray detector designed by a group from Bristol University. A spherical aluminum vessel of diameter 75 cm contains a gas scintillation mixture and a thin spherical shell of Pilot 425 plastic, and forms a single optical cavity viewed by 16 photomultipliers. Particle tracks through the detector may be characterized by their impact parameter p and by whether or not they pass through the cup of plastic scintillator placed between the sphere and the spacecraft body (referred to below as the Anti-Coincidence Detector or ACD). Individual particle charges are determined by separately measuring the gas scintillation and the Cerenkov emission from the plastic shell. This is possible because of the quite different distribution in time of these emissions

    Doppler measurements of the ionosphere on the occasion of the Apollo-Soyuz test project. Part 1: Computer simulation of ionospheric-induced Doppler shifts

    Get PDF
    A computer simulation of the ionospheric experiment of the Apollo-Soyuz Test Project (ASTP) was performed. ASTP is the first example of USA/USSR cooperation in space and is scheduled for summer 1975. The experiment consists of performing dual-frequency Doppler measurements (at 162 and 324 MHz) between the Apollo Command Service Module (CSM) and the ASTP Docking Module (DM), both orbiting at 221-km height and at a relative distance of 300 km. The computer simulation showed that, with the Doppler measurement resolution of approximately 3 mHz provided by the instrumentation (in 10-sec integration time), ionospheric-induced Doppler shifts will be measurable accurately at all times, with some rare exceptions occurring when the radio path crosses regions of minimum ionospheric density. The computer simulation evaluated the ability of the experiment to measure changes of columnar electron content between CSM and DM (from which horizontal gradients of electron density at 221-km height can be obtained) and to measure variations in DM-to-ground columnar content (from which an averaged columnar content and the electron density at the DM can be deduced, under some simplifying assumptions)

    Cavitation-induced force transition in confined viscous liquids under traction

    Full text link
    We perform traction experiments on simple liquids highly confined between parallel plates. At small separation rates, we observe a simple response corresponding to a convergent Poiseuille flow. Dramatic changes in the force response occur at high separation rates, with the appearance of a force plateau followed by an abrupt drop. By direct observation in the course of the experiment, we show that cavitation accounts for these features which are reminiscent of the utmost complex behavior of adhesive films under traction. Surprisingly enough, this is observed here in purely viscous fluids.Comment: Submitted to Physical Review Letters on May 31, 2002. Related informations on http://www.crpp.u-bordeaux.fr/tack.htm

    Antibody responses to nasopharyngeal carriage of Streptococcus pneumoniae in adults: A longitudinal household study

    Get PDF
    Background. Natural immunity to Streptococcus pneumoniae is thought to be induced by exposure to S. pneumoniae or cross-reactive antigens. No longitudinal studies of carriage of and immune responses to S. pneumoniae have been conducted using sophisticated immunological laboratory techniques.Methods. We enrolled 121 families with young children into this study. Nasopharyngeal (NP) swabs were collected monthly for 10 months from all family members and were cultured in a standard fashion. Cultured S. pneumoniae isolates were serotyped. At the beginning (month 0) and end (month 10) of the study, venous blood was collected from family members 118 years old. Serotype-specific antipolysaccharide immunoglobulin G (IgG) and functional antibody and antibodies to pneumolysin, pneumococcal surface protein A (PspA), and pneumococcal surface antigen A (PsaA) were measured in paired serum samples.Results. Levels of anticapsular IgG increased significantly after carriage of serotypes 9V, 14, 18C, 19F, and 23F by an individual or family member. For serotype 14, a higher level of anticapsular IgG at the beginning of the study was associated with reduced odds of carriage (P = .0006). There was a small (similar to 20%) but significant increase in titers of antibodies to PsaA and pneumolysin but no change in titers of antibody to PspA.Conclusions. Adults respond to NP carriage by mounting anticapsular and weak antiprotein antibody responses, and naturally induced anticapsular IgG can prevent carriage

    Coherent states for the hydrogen atom

    Get PDF
    We construct wave packets for the hydrogen atom labelled by the classical action-angle variables with the following properties. i) The time evolution is exactly given by classical evolution of the angle variables. (The angle variable corresponding to the position on the orbit is now non-compact and we do not get exactly the same state after one period. However the gross features do not change. In particular the wave packet remains peaked around the labels.) ii) Resolution of identity using this overcomplete set involves exactly the classical phase space measure. iii) Semi-classical limit is related to Bohr-Sommerfield quantization. iv) They are almost minimum uncertainty wave packets in position and momentum.Comment: 9 pages, 2 figures, minor change in language and journal reference adde
    corecore