17 research outputs found

    Repeated TACE in HCC after Fontan surgery and situs viscerum inversus: A case report

    Get PDF
    We describe the case of a 32-year-old man who developed a liver neoplasm due to previous Fontan surgery (FS) for a single ventricle anomaly and situs viscerum inversus. He was admitted to our hospital for suspected hepatocellular carcinoma during an Ultrasound (US) follow up. Computed tomography (CT) showed features of chronic liver disease and 7 cm hepatic nodule with arterial enhancement. Laboratory analyses documented preserved liver function and increased levels of alpha-fetoprotein. Trans-arterial-chemoembolization (TACE) was performed obtaining complete necrosis at 4 weeks of follow up and significant reduction of alpha-fetoprotein. The patient is currently in follow-up, being evaluated for further treatments and/or combined liver-heart transplantation. TACE is a therapeutic option for the treatment of patients with unresectable hepatocellular carcinoma (HCC) and with severe heart disease, like those submitted to FS and with also other vascular abnormalities like those correlated to situs viscerum inversus

    Correlations between chest-CT and laboratory parameters in SARS-CoV-2 pneumonia: A single-center study from Italy

    Get PDF
    To investigate the relationship between damaged lung assessed by chest computed tomography (CT) scan and laboratory biochemical parameters with the aim of finding other diagnostic tools. Patients who underwent chest CT for suspected Corona Virus Disease-2019 (COVID-19) pneumonia at the emergency department admission in the first phase of COVID-19 epidemic in Italy were retrospectively analyzed. Patients with both negative chest CT and absence of the novel coronavirus in nasopharyngeal or oropharyngeal real-time reverse transcriptase polymerase chain reaction (RT-PCR) swabs were excluded from the study. A total of 462 patients with positive CT scans for interstitial pneumonia were included in the study (250 males and 212 females, mean age 57 ± 17 years, range 18–89). Of these, 344 were positive to RT-PCR test, 118 were negative to double RT-PCR tests. CTs were analyzed for quantification of affected lung volume visually and by dedicated software. Statistical analysis to evaluate the relationship between laboratory analyses and CT patterns and amount of damaged lung related with COVID-19 pneumonia was performed in 2 groups of patients: positive RT-PCR COVID-19 group and negative RT-PCR COVID-19 group, but both with positive CT scans for interstitial pneumonia. Lymphocytopenia, C-reactive protein (CRP), lactate dehydrogenase (LDH), d-dimer, and fibrinogen increased levels occurred in most patients without statistically significant differences between the 2 groups with CT scans suggestive for COVID-19. In fact, in both groups the volume of lung damage was strongly associated with altered laboratory test results, even for patients with negative RT-PCR test. The decreased number of lymphocytes, and the increased levels of CRP, LDH, d-dimer, and fibrinogen levels are associated with SARS-CoV 2 related pneumonia. This may be useful as an additional diagnostic tool in patients with double negative RT-PCR assay and with highly suspected clinic and chest CT features for COVID-19 to isolate patients in a pandemic period.publishedVersio

    Flow-diverter treatment for renal artery aneurysms: One-year follow-up of a multicentric preliminary experience

    Get PDF
    PURPOSERenal artery aneurysms (RAAs) are rare in the general population, although the true incidence and natural history remain elusive. Conventional endovascular therapies such as coil embolization or covered stent graft may cause sidebranches occlusion, leading to organ infarction. Flow-diverters (FD) have been firstly designed to treat cerebrovascular aneurysms, but their use may be useful to treat complex RAAs presenting sidebraches arising from aneurysmal sac. To evaluate mid-term follow-up (FUP) safety and efficacy of FD during treatment of complex RAAs.METHODSBetween November 2019 and April 2020, 7 RAAs were identified in 7 patients (4 men, 3 women; age range 55-82 years; median 67 years) and treated by FD. Procedural details, complications, morbidity and mortality, aneurysm occlusion and segmental artery patency were retrospectively reviewed. Twelve months computed tomography angiography (CTA) FUP was evaluated for all cases.RESULTDeployment of FD was successful in all cases. One intraprocedural technical complication was encountered with one FD felt down into aneurism sac which requiring additional telescopic stenting. One case at 3 months CTA FUP presented same complication, requiring same rescue technique. At 12 months CTA FUP 5 cases of size shrinkage and 2 cases of stable size were documented. No rescue surgery or major intraprocedural or mid-term FUP complication was seen.CONCLUSIONComplex RAAs with two or more sidebranches can be safely treated by FD. FD efficacy for RAA needs a further validation at long term FUP by additional large prospective studies

    The AGILE Mission

    Get PDF
    AGILE is an Italian Space Agency mission dedicated to observing the gamma-ray Universe. The AGILE's very innovative instrumentation for the first time combines a gamma-ray imager (sensitive in the energy range 30 MeV-50 GeV), a hard X-ray imager (sensitive in the range 18-60 keV), a calorimeter (sensitive in the range 350 keV-100 MeV), and an anticoincidence system. AGILE was successfully launched on 2007 April 23 from the Indian base of Sriharikota and was inserted in an equatorial orbit with very low particle background. Aims. AGILE provides crucial data for the study of active galactic nuclei, gamma-ray bursts, pulsars, unidentified gamma-ray sources, galactic compact objects, supernova remnants, TeV sources, and fundamental physics by microsecond timing. Methods. An optimal sky angular positioning (reaching 0.1 degrees in gamma- rays and 1-2 arcmin in hard X-rays) and very large fields of view (2.5 sr and 1 sr, respectively) are obtained by the use of Silicon detectors integrated in a very compact instrument. Results. AGILE surveyed the gamma- ray sky and detected many Galactic and extragalactic sources during the first months of observations. Particular emphasis is given to multifrequency observation programs of extragalactic and galactic objects. Conclusions. AGILE is a successful high-energy gamma-ray mission that reached its nominal scientific performance. The AGILE Cycle-1 pointing program started on 2007 December 1, and is open to the international community through a Guest Observer Program

    AGILE detection of a rapid Îł-ray flare from the blazar PKS 1510-089 during the GASP-WEBT monitoring

    Get PDF
    We report the detection by the AGILE satellite of a rapid gamma-ray flare from the powerful gamma-ray quasar PKS 1510-089, during a pointing centered on the Galactic Center region from 1 March to 30 March 2008. This source has been continuosly monitored in the radio-to-optical bands by the GLAST-AGILE Support Program (GASP) of the Whole Earth Blazar Telescope (WEBT). Moreover, the gamma-ray flaring episode triggered three ToO observations by the Swift satellite in three consecutive days, starting from 20 March 2008. In the period 1-16 March 2008, AGILE detected gamma-ray emission from PKS 1510-089 at a significance level of 6.2-sigma with an average flux over the entire period of (84 +/- 17) x 10^{-8} photons cm^{-2} s^{-1} for photon energies above 100 MeV. After a predefined satellite re-pointing, between 17 and 21 March 2008, AGILE detected the source at a significance level of 7.3-sigma, with an average flux (E > 100 MeV) of (134 +/- 29) x 10^{-8} photons cm^{-2} s^{-1} and a peak level of (281 +/- 68) x 10^{-8} photons cm^{-2} s^{-1} with daily integration. During the observing period January-April 2008, the source also showed an intense and variable optical activity, with several flaring episodes and a significant increase of the flux was observed at millimetric frequencies. Moreover, in the X-ray band the Swift/XRT observations seem to show an harder-when-brighter behaviour of the source spectrum. The spectral energy distribution of mid-March 2008 is modelled with a homogeneous one-zone synchrotron self Compton emission plus contributions from inverse Compton scattering of external photons from both the accretion disc and the broad line region. Indeed, some features in the optical-UV spectrum seem to indicate the presence of Seyfert-like components, such as the little blue bump and the big blue bump

    Management of acute adverse reactions by contrast medium

    No full text
    The use of contrast medium (CM) in diagnostic imaging is mandatory for diagnosis, characterization, staging, control during and after therapies and in the follow-up of patients affected by various diseases. Contrast agents are atypical drugs, with no therapeutic effects, used for diagnosis, administered in large doses, often at high speed in the bloodstream. Like all drugs, there are also rarely serious adverse reactions due to contrast medium. The Radiologist has the responsibility of choosing the contrast medium that best suits the specific clinical needs, and how administrate it. Radiologist must insert in the report what he did and the description of adverse event due to CM. The Italian Society of Medical and Interventional Radiology (SIRM), through its study section on contrast agents, has realized a consensus document together with the Italian Society of Anesthesia, Analgesia Resuscitation and Intensive Care (SIAARTI) on the management of acute adverse reactions due to contrast agents. The document deals of the various aspects related to the patient’s risk conditions, the type of adverse reactions and how to treat them. Moreover, the document indicates the medical instruments, drugs and the operating procedures necessary to guarantee the safety of the patient and of the health personnel. The methods of training health personnel involved in the management of emergencies due to administration of the contrast agent are also illustrated. The aim of this work is to spread the knowledge of the document SIRM-SIAARTI for the management of emergencies from contrast medium, illustrating the main topics

    Endovascular bail-out mechanical thrombectomy of a post-CEA acute internal carotid occlusion with consensual intracranial occlusion: A challenging case

    No full text
    Acute carotid occlusion is a rare but important complication that can occur after a carotid endoacrterectomy (CEA) procedure. Standard intervention after a re-occlusion is usually surgical. We reported a case of a 78-year old patient with acute internal carotid occlusion after a CEA and sociated intracranial embolization to the posterior communicating artery. Surgical approach was therefore excluded because of the above-mentioned cerebral perfusion deficit. Endovascular treatment allowed to restore the proper ICA vessel caliber and the cerebral blood flow through a thromboaspiration catheter. Moreover, the procedure was performed using devices usually intended for other body district. Endovascular treatment could represent an alternative treatment in post-CEA acute occlusions, especially in patient with associated intracranial perfusion deficit, allowing the operator to resolve both issues and reduce the overall ischemic time

    Use of Intravascular Ultrasound to Improve Diagnosis and Treatment of Transjugular Intrahepatic Portosystemic Shunt Dysfunction in Patients in the Long-term Follow-up

    No full text
    Aim: To evaluate the efficacy of intravascular ultrasound (IVUS) in transjugular intrahepatic portosystemic shunt (TIPS) revision associated with phlebography and invasive pressure measurement in patients with clinical or radiological signs of TIPS malfunction. Background: Four patients underwent TIPS revision between February and August 2021. Right internal jugular vein access was achieved under ultrasonographic guidance, a catheter was advanced to achieve the Inferior Vena Cava (IVC) and afterward the Portal vein through the TIPS. Once the Portal vein was achieved, a phlebography was performed, followed by invasive pressure measurement and IVUS exam over the guidewire. Based on the combination of phlebography, invasive pressure measurement, and IVUS evaluations, TIPS dysfunction was treated either with angioplasty or stent apposition. Case description: In all patients, we obtained the reduction of porto-systemic gradient. In three patients, angioplasty with a 10 mm diameter balloon catheter was performed. Anticoagulation therapy was added to one patient. In one patient, the Viatorr's proximal extremity in the suprahepatic vein wall was dislocated, so it was lengthened with a "Viabahn" covered stent. None of the patients developed hepatic encephalopathy after both TIPS placement and TIPS revision. No complications related to the procedure were observed during the follow-up. Clinical improvement in the immediate follow-up period was observed in all patients. In two patients, the abdominal ascites resolved. In another one, the abdominal pain disappeared, and a reduction of the longitudinal spleen diameter was recorded at 3 months follow-up. Conclusion: The use of IVUS allowed us to correctly visualize the organic cause of TIPS malfunction and to obtain direct visualization of the results of endovascular treatment. How to cite this article: Morosetti D, Lenci I, Argirò R, et al. Use of Intravascular Ultrasound to Improve Diagnosis and Treatment of Transjugular Intrahepatic Portosystemic Shunt Dysfunction in Patients in the Long-term Follow-up. Euroasian J Hepato-Gastroenterol 2022;12(1):50-56
    corecore