63 research outputs found
Output Impedance Improvement Using Coupled Inductors
When using a single DC/DC converter with multiple outputs and having a buck topology, which has one filter inductor per output, the designer can choose to couple these outputs together. This paper demonstrates additional benefits of coupling output inductors together. Apart from saving mass and volume, and due to an improved small signal behaviour it also reduces the output impedance of the regulated output. The paper will analyse a seven output push-pull converter used as a space power converter module and verify the theoretical results with experimental measurements
The second flight of the SUNRISE balloon-borne solar observatory: overview of instrument updates, the flight, the data and first results
The SUNRISE balloon-borne solar observatory, consisting of a 1~m aperture
telescope that provided a stabilized image to a UV filter imager and an imaging
vector polarimeter, carried out its second science flight in June 2013. It
provided observations of parts of active regions at high spatial resolution,
including the first high-resolution images in the Mg~{\sc ii}~k line. The
obtained data are of very high quality, with the best UV images reaching the
diffraction limit of the telescope at 3000~\AA\ after Multi-Frame Blind
Deconvolution reconstruction accounting for phase-diversity information. Here a
brief update is given of the instruments and the data reduction techniques,
which includes an inversion of the polarimetric data. Mainly those aspects that
evolved compared with the first flight are described. A tabular overview of the
observations is given. In addition, an example time series of a part of the
emerging active region NOAA AR~11768 observed relatively close to disk centre
is described and discussed in some detail. The observations cover the pores in
the trailing polarity of the active region, as well as the polarity inversion
line where flux emergence was ongoing and a small flare-like brightening
occurred in the course of the time series. The pores are found to contain
magnetic field strengths ranging up to 2500~G and, while large pores are
clearly darker and cooler than the quiet Sun in all layers of the photosphere,
the temperature and brightness of small pores approach or even exceed those of
the quiet Sun in the upper photosphere.Comment: Accepted for publication in The Astrophysical Journa
The Sunrise Mission
The first science flight of the balloon-borne \Sunrise telescope took place
in June 2009 from ESRANGE (near Kiruna/Sweden) to Somerset Island in northern
Canada. We describe the scientific aims and mission concept of the project and
give an overview and a description of the various hardware components: the 1-m
main telescope with its postfocus science instruments (the UV filter imager
SuFI and the imaging vector magnetograph IMaX) and support instruments (image
stabilizing and light distribution system ISLiD and correlating wavefront
sensor CWS), the optomechanical support structure and the instrument mounting
concept, the gondola structure and the power, pointing, and telemetry systems,
and the general electronics architecture. We also explain the optimization of
the structural and thermal design of the complete payload. The preparations for
the science flight are described, including AIV and ground calibration of the
instruments. The course of events during the science flight is outlined, up to
the recovery activities. Finally, the in-flight performance of the
instrumentation is briefly summarized.Comment: 35 pages, 17 figure
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise balloon-borne solar observatory
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by
four institutions in Spain that flew on board the Sunrise balloon-borne
telesocope in June 2009 for almost six days over the Arctic Circle. As a
polarimeter IMaX uses fast polarization modulation (based on the use of two
liquid crystal retarders), real-time image accumulation, and dual beam
polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the
instrument uses a LiNbO3 etalon in double pass and a narrow band pre-filter to
achieve a spectral resolution of 85 mAA. IMaX uses the high Zeeman sensitive
line of Fe I at 5250.2 AA and observes all four Stokes parameters at various
points inside the spectral line. This allows vector magnetograms, Dopplergrams,
and intensity frames to be produced that, after reconstruction, reach spatial
resolutions in the 0.15-0.18 arcsec range over a 50x50 arcsec FOV. Time
cadences vary between ten and 33 seconds, although the shortest one only
includes longitudinal polarimetry. The spectral line is sampled in various ways
depending on the applied observing mode, from just two points inside the line
to 11 of them. All observing modes include one extra wavelength point in the
nearby continuum. Gauss equivalent sensitivities are four Gauss for
longitudinal fields and 80 Gauss for transverse fields per wavelength sample.
The LOS velocities are estimated with statistical errors of the order of 5-40
m/s. The design, calibration and integration phases of the instrument, together
with the implemented data reduction scheme are described in some detail.Comment: 17 figure
Constitutive and Treatment-Induced CXCL8-Signalling Selectively Modulates the Efficacy of Anti-Metabolite Therapeutics in Metastatic Prostate Cancer
<div><h3>Background</h3><p>The current study was undertaken to characterize the effect of anti-metabolites on inducing CXCL8 signaling and determining whether the constitutive and/or drug-induced CXCL8 signaling in metastatic prostate cancer (CaP) cells modulates their sensitivity to this class of agent.</p> <h3>Methods</h3><p>The response of metastatic CaP cells to 5-Fluorouracil (5-FU), Pemetrexed or Tomudex was determined using cell count assays, flow cytometry and PARP cleavage analysis. Quantitative-PCR, ELISA and immunoblots were employed to determine effects of drugs or CXCL8 administration on target gene/protein expression.</p> <h3>Results</h3><p>Administration of 5-FU but not pemetrexed potentiated CXCL8 secretion and increased CXCR1 and CXCR2 gene expression in metastatic PC3 cells. Consistent with this, the inhibition of CXCL8 signaling using a CXCR2 antagonist, AZ10397767, increased the cytotoxicity of 5-FU by 4-fold (P<0.001), and increased 5-FU-induced apoptosis in PC3 cells (P<0.01). In contrast, while administration of AZ10397767 had no effect on the sensitivity of pemetrexed, the CXCR2 antagonist exerted the greatest effect in increasing the sensitivity of PC3 cells to Tomudex, a directed thymidylate synthase (TS) inhibitor. Subsequent experiments confirmed that administration of recombinant human CXCL8 increased TS expression, a response mediated in part by the CXCR2 receptor. Moreover, siRNA-mediated knockdown of the CXCL8-target gene Bcl-2 increased the sensitivity of PC3 cells to 5-FU.</p> <h3>Conclusions</h3><p>CXCL8 signaling provides a selective resistance of metastatic prostate cancer cells to specific anti-metabolites by promoting a target-associated resistance, in addition to underpinning an evasion of treatment-induced apoptosis.</p> </div
Intensity contrast of solar network and faculae close to the solar limb, observed from two vantage points
The brightness of faculae and network depends on the angle at which they are
observed and the magnetic flux density. Close to the limb, assessment of this
relationship has until now been hindered by the increasingly lower signal in
magnetograms. This preliminary study aims at highlighting the potential of
using simultaneous observations from different vantage points to better
determine the properties of faculae close to the limb. We use data from the
Solar Orbiter/Polarimetric and Helioseismic Imager (SO/PHI), and the Solar
Dynamics Observatory/Helioseismic and Magnetic Imager (SDO/HMI), recorded at
angular separation of their lines of sight at the Sun. We use
continuum intensity observed close to the limb by SO/PHI and complement it with
the co-observed from SDO/HMI, originating closer to disc centre
(as seen by SDO/HMI), thus avoiding the degradation of the magnetic field
signal near the limb. We derived the dependence of facular brightness in the
continuum on disc position and magnetic flux density from the combined
observations of SO/PHI and SDO/HMI. Compared with a single point of view, we
were able to obtain contrast values reaching closer to the limb and to lower
field strengths. We find the general dependence of the limb distance at which
the contrast is maximum on the flux density to be at large in line with single
viewpoint observations, in that the higher the flux density is, the closer the
turning point lies to the limb. There is a tendency, however, for the maximum
to be reached closer to the limb when determined from two vantage points. We
note that due to the preliminary nature of this study, these results must be
taken with caution. Our analysis shows that studies involving two viewpoints
can significantly improve the detection of faculae near the solar limb and the
determination of their brightness contrast relative to the quiet Sun
The ratio of horizontal to vertical displacement in solar oscillations estimated from combined SO/PHI and SDO/HMI observations
In order to make accurate inferences about the solar interior using
helioseismology, it is essential to understand all the relevant physical
effects on the observations. One effect to understand is the (complex-valued)
ratio of the horizontal to vertical displacement of the p- and f-modes at the
height at which they are observed. Unfortunately, it is impossible to measure
this ratio directly from a single vantage point, and it has been difficult to
disentangle observationally from other effects. In this paper we attempt to
measure the ratio directly using 7.5 hours of simultaneous observations from
the Polarimetric and Helioseismic Imager on board Solar Orbiter and the
Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory. While
image geometry problems make it difficult to determine the exact ratio, it
appears to agree well with that expected from adiabatic oscillations in a
standard solar model. On the other hand it does not agree with a commonly used
approximation, indicating that this approximation should not be used in
helioseismic analyses. In addition, the ratio appears to be real-valued.Comment: Accepted for publication in Astronomy & Astrophysics. 8 pages, 8
figure
Recommended from our members
The Sunrise Mission
The first science flight of the balloon-borne Sunrise telescope took place in June 2009 from ESRANGE (near Kiruna/Sweden) to Somerset Island in northern Canada. We describe the scientific aims and mission concept of the project and give an overview and a description of the various hardware components: the 1-m main telescope with its postfocus science instruments (the UV filter imager SuFI and the imaging vector magnetograph IMaX) and support instruments (image stabilizing and light distribution system ISLiD and correlating wavefront sensor CWS), the optomechanical support structure and the instrument mounting concept, the gondola structure and the power, pointing, and telemetry systems, and the general electronics architecture. We also explain the optimization of the structural and thermal design of the complete payload. The preparations for the science flight are described, including AIV and ground calibration of the instruments. The course of events during the science flight is outlined, up to the recovery activities. Finally, the in-flight performance of the instrumentation is discussed. © 2010 The Author(s)
CMAG: a mission to study and monitor the inner corona magnetic field
Measuring magnetic fields in the inner corona, the interface between the solar chromosphere and outer corona, is of paramount importance if we aim to understand the energetic transformations taking place there, and because it is at the origin of processes that lead to coronal heating, solar wind acceleration, and of most of the phenomena relevant to space weather. However, these measurements are more difficult than mere imaging because polarimetry requires differential photometry. The coronal magnetograph mission (CMAG) has been designed to map the vector magnetic field, line-of-sight velocities, and plane-of-the-sky velocities of the inner corona with unprecedented spatial and temporal resolutions from space. This will be achieved through full vector spectropolarimetric observations using a coronal magnetograph as the sole instrument on board a spacecraft, combined with an external occulter installed on another spacecraft. The two spacecraft will maintain a formation flight distance of 430 m for coronagraphic observations, which requires a 2.5 m occulter disk radius. The mission will be preferentially located at the Lagrangian L5 point, offering a significant advantage for solar physics and space weather research. Existing ground-based instruments face limitations such as atmospheric turbulence, solar scattered light, and long integration times when performing coronal magnetic field measurements. CMAG overcomes these limitations by performing spectropolarimetric measurements from space with an external occulter and high-image stability maintained over time. It achieves the necessary sensitivity and offers a spatial resolution of 2.5″ and a temporal resolution of approximately one minute, in its nominal mode, covering the range from 1.02 solar radii to 2.5 radii. CMAG relies on proven European technologies and can be adapted to enhance any other solar mission, offering potential significant advancements in coronal physics and space weather modeling and monitoring
- …