50 research outputs found

    Active flow control systems architectures for civil transport aircraft

    Get PDF
    Copyright @ 2010 American Institute of Aeronautics and AstronauticsThis paper considers the effect of choice of actuator technology and associated power systems architecture on the mass cost and power consumption of implementing active flow control systems on civil transport aircraft. The research method is based on the use of a mass model that includes a mass due to systems hardware and a mass due to the system energy usage. An Airbus A320 aircraft wing is used as a case-study application. The mass model parameters are based on first-principle physical analysis of electric and pneumatic power systems combined with empirical data on system hardware from existing equipment suppliers. Flow control methods include direct fluidic, electromechanical-fluidic, and electrofluidic actuator technologies. The mass cost of electrical power distribution is shown to be considerably less than that for pneumatic systems; however, this advantage is reduced by the requirement for relatively heavy electrical power management and conversion systems. A tradeoff exists between system power efficiency and the system hardware mass required to achieve this efficiency. For short-duration operation the flow control solution is driven toward lighter but less power-efficient systems, whereas for long-duration operation there is benefit in considering heavier but more efficient systems. It is estimated that a practical electromechanical-fluidic system for flow separation control may have a mass up to 40% of the slat mass for a leading-edge application and 5% of flap mass for a trailing-edge application.This work is funded by the Sixth European Union Framework Programme as part of the AVERT project (Contract No. AST5-CT-2006-030914

    Direct observation of a Fermi surface and superconducting gap in LuNi2B2C

    Get PDF
    We measured the Fermi surface (FS), band dispersion and superconducting gap in LuNi2B2C using Angle Resolved Photoemission Spectroscopy. Experimental data were compared with the tight-binding version of the Linear Muffin-Tin Orbital (LMTO) method and Linearized Augmented Plane-Wave (LAPW) calculations. We found reasonable agreement between the two calculations and experimental data. The measured FS exhibits large parallel regions with a nesting vector that agrees with a previous positron annihilation study and calculations of the generalized susceptibility. The measured dispersion curves also agree reasonably well with the TB-LMTO calculations, albeit with some differences in the strength of the hybridization. In addition, the spectrum in the superconducting state revealed a 2meV superconducting gap. The data also clearly shows the presence of a coherent peak above the chemical potential, that originates from thermally excited electrons above the energy of 2 delta. This feature was not previously observed in the Lu-based material.Comment: 5 pages, 3 figure

    Body iron metabolism and pathophysiology of iron overload

    Get PDF
    Iron is an essential metal for the body, while excess iron accumulation causes organ dysfunction through the production of reactive oxygen species. There is a sophisticated balance of body iron metabolism of storage and transport, which is regulated by several factors including the newly identified peptide hepcidin. As there is no passive excretory mechanism of iron, iron is easily accumulated when exogenous iron is loaded by hereditary factors, repeated transfusions, and other diseased conditions. The free irons, non-transferrin-bound iron, and labile plasma iron in the circulation, and the labile iron pool within the cells, are responsible for iron toxicity. The characteristic features of advanced iron overload are failure of vital organs such as liver and heart in addition to endocrine dysfunctions. For the estimation of body iron, there are direct and indirect methods available. Serum ferritin is the most convenient and widely available modality, even though its specificity is sometimes problematic. Recently, new physical detection methods using magnetic resonance imaging and superconducting quantum interference devices have become available to estimate iron concentration in liver and myocardium. The widely used application of iron chelators with high compliance will resolve the problems of organ dysfunction by excess iron and improve patient outcomes

    The European Solar Telescope

    Get PDF
    The European Solar Telescope (EST) is a project aimed at studying the magnetic connectivity of the solar atmosphere, from the deep photosphere to the upper chromosphere. Its design combines the knowledge and expertise gathered by the European solar physics community during the construction and operation of state-of-the-art solar telescopes operating in visible and near-infrared wavelengths: the Swedish 1m Solar Telescope, the German Vacuum Tower Telescope and GREGOR, the French TĂ©lescope HĂ©liographique pour l’Étude du MagnĂ©tisme et des InstabilitĂ©s Solaires, and the Dutch Open Telescope. With its 4.2 m primary mirror and an open configuration, EST will become the most powerful European ground-based facility to study the Sun in the coming decades in the visible and near-infrared bands. EST uses the most innovative technological advances: the first adaptive secondary mirror ever used in a solar telescope, a complex multi-conjugate adaptive optics with deformable mirrors that form part of the optical design in a natural way, a polarimetrically compensated telescope design that eliminates the complex temporal variation and wavelength dependence of the telescope Mueller matrix, and an instrument suite containing several (etalon-based) tunable imaging spectropolarimeters and several integral field unit spectropolarimeters. This publication summarises some fundamental science questions that can be addressed with the telescope, together with a complete description of its major subsystems

    Real-time multiplex analysis of four beta-thalassemia mutations employing surface plasmon resonance and biosensor technology

    No full text
    In this paper, biospecific interaction analysis (BIA) employing surface plasmon resonance (SPR) and biosensor technologies was applied to the analysis of multiple mutations of the human beta-globin gene. To this aim, large target polymerase chain reaction (PCR) products were immobilized on sensor chips and then probes detecting beta degrees 39 (C>T), beta degrees IVSI-1 (G>A), beta(+)IVSI-6 (T>C) and beta(+)IVSI-110 (G>A) thalassemia mutations were sequentially injected. In this study, a total of ten normal and seven heterozygous subjects, and six homozygous patients were considered. The results obtained allow to conclude that discrimination between normal subjects, heterozygous, and homozygous patients is readily achieved for all the four mutations by PCR amplification of genomic DNA containing all the regions corresponding to the same mutations, immobilization of the same PCR products, and hybridization. To our knowledge the procedure described here is the first reported on the use of SPR-based BIA and biosensor technology for multiple detections of point mutations

    An updated overview of clinical guidelines for chronic low back pain management in primary care

    No full text
    OBJECTIVES: In the past decade many countries around the world have produced clinical practice guidelines to assist practitioners in providing a care that is aligned with the best evidence. The aim of this study was to present and compare the most established evidence-based recommendations for the management of chronic nonspecific low back pain in primary care derived from current high-quality international guidelines. METHODS: Guidelines published or updated since 2002 were selected by searching PubMed, CINAHL, EMBASE, guidelines databases, and the World Wide Web. The methodological quality of the guidelines was assessed by three authors independently, using the Appraisal of Guidelines for Research and Evaluation (AGREE) Instrument. Guideline recommendations were synthesized into diagnostic and therapeutic approaches that were supported by strong, moderate or weak evidence. RESULTS: Thirteen guidelines were included. In general, the quality was satisfactory. Guidelines had highest scores on clarity and presentation and scope and purpose domains, and lowest scores on applicability. There was a strong consensus among all the guidelines particularly regarding the use of diagnostic triage and the assessment of prognostic factors. Consistent therapeutic recommendations were information, exercise therapy, multidisciplinary treatment, and combined physical and psychological interventions. CONCLUSION: Compared to previous assessments, the average quality of the guidelines dealing with chronic low back pain has improved. Furthermore, all guidelines are increasingly aligning in providing therapeutic recommendations that are clearly differentiated from those formulated for acute pain. However, there is still a need for improving quality and generating new evidence for this particular condition
    corecore