130 research outputs found

    Shortening of the Short Refractory Periods in Short QT Syndrome.

    Get PDF
    BACKGROUND: Diagnosis of short QT syndrome (SQTS) remains difficult in case of borderline QT values as often found in normal populations. Whether some shortening of refractory periods (RP) may help in differentiating SQTS from normal subjects is unknown. METHODS AND RESULTS: Atrial and right ventricular RP at the apex and right ventricular outflow tract as determined during standard electrophysiological study were compared between 16 SQTS patients (QTc 324±24 ms) and 15 controls with similar clinical characteristics (QTc 417±32 ms). Atrial RP were significantly shorter in SQTS compared with controls at 600- and 500-ms basic cycle lengths. Baseline ventricular RP were significantly shorter in SQTS patients than in controls, both at the apex and right ventricular outflow tract and for any cycle length. Differences remained significant for RP of any subsequent extrastimulus at any cycle length and any pacing site. A cut-off value of baseline RP <200 ms at the right ventricular outflow tract either at 600- or 500-ms cycle length had a sensitivity of 86% and a specificity of 100% for the diagnosis of SQTS. CONCLUSIONS: Patients with SQTS have shorter ventricular RP than controls, both at baseline during various cycle lengths and after premature extrastimuli. A cut-off value of 200 ms at the right ventricular outflow tract during 600- and 500-ms basic cycle length may help in detecting true SQTS from normal subjects with borderline QT values

    Ultrasound in the evaluation of enthesitis: Status and perspectives

    Get PDF
    Introduction: An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter.Methods: Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed.Results: After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%).Conclusions: Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications. © 2011 Gandjbakhch et al.; licensee BioMed Central Ltd

    The reliability of musculoskeletal ultrasound in the detection of cartilage abnormalities at the metacarpo-phalangeal joints

    Get PDF
    SummaryObjectiveTo assess the reliability of ultrasound (US) in detecting cartilage abnormalities at the metacarpo-phalangeal (MCP) joints in people with cartilage pathology.MethodsNine expert ultrasonographers initially achieved consensus on definitions and scanning protocols. They then examined the second to fifth MCP joints of the dominant hand of eight people with hand osteoarthritis (OA). US examinations were conducted in two rounds, with independent blinded evaluations of cartilage lesions. Global cartilage abnormalities were assessed by applying a dichotomous (presence/absence) score; in addition, the following lesions were evaluated using the same scoring system: loss of anechoic structure and/or thinning of the cartilage layer, and irregularities and/or loss of sharpness of at least one cartilage margin. Reliability was assessed using kappa (k) coefficients.ResultsThirty-two joints were examined. Intra-observer k values ranged from 0.52 to 1 for global cartilage abnormalities; k values ranged from 0.54 to 0.94 for loss of anechoic structure and/or thinning of cartilage layer and from 0.59 to 1 for irregularities and/or loss of sharpness of at least one cartilage margin. Values of k for inter-observer reliability were 0.80 for global cartilage abnormalities, 0.62 for loss of anechoic structure and/or thinning of cartilage layer, and 0.39 for irregularities and/or loss of sharpness of at least one cartilage margin.ConclusionUS is a reliable imaging modality for the detection of cartilage abnormalities in patients with cartilage pathology in the MCP joints. The analysis of specific cartilage measures showed more variable results that may be improved by modifying definitions and further standardization of US techniques

    The reliability of musculoskeletal ultrasound in the detection of cartilage abnormalities at the metacarpo-phalangeal joints

    Get PDF
    Objective: To assess the reliability of ultrasound (US) in detecting cartilage abnormalities at the metacarpo-phalangeal (MCP) joints in people with cartilage pathology. Methods: Nine expert ultrasonographers initially achieved consensus on definitions and scanning protocols. They then examined the second to fifth MCP joints of the dominant hand of eight people with hand osteoarthritis (OA). US examinations were conducted in two rounds, with independent blinded evaluations of cartilage lesions. Global cartilage abnormalities were assessed by applying a dichotomous (presence/absence) score; in addition, the following lesions were evaluated using the same scoring system: loss of anechoic structure and/or thinning of the cartilage layer, and irregularities and/or loss of sharpness of at least one cartilage margin. Reliability was assessed using kappa (k) coefficients. Results: Thirty-two joints were examined. Intra-observer k values ranged from 0.52 to 1 for global cartilage abnormalities; k values ranged from 0.54 to 0.94 for loss of anechoic structure and/or thinning of cartilage layer and from 0.59 to 1 for irregularities and/or loss of sharpness of at least one cartilage margin. Values of k for inter-observer reliability were 0.80 for global cartilage abnormalities, 0.62 for loss of anechoic structure and/or thinning of cartilage layer, and 0.39 for irregularities and/or loss of sharpness of at least one cartilage margin. Conclusion: US is a reliable imaging modality for the detection of cartilage abnormalities in patients with cartilage pathology in the MCP joints. The analysis of specific cartilage measures showed more variable results that may be improved by modifying definitions and further standardization of US techniques. © 2012 Osteoarthritis Research Society International

    Atlas of the OMERACT Heel Enthesitis MRI Scoring System (HEMRIS)

    Get PDF
    Objective: Assessment of enthesitis, a key feature in spondyloarthritis (SpA) and psoriatic arthritis (PsA), using objective and sensitive methods is pivotal in clinical trials. MRI allows detection of both soft tissue and intra-osseous changes of enthesitis. This article presents an atlas for the Outcome Measures in Rheumatology (OMERACT) Heel Enthesitis Magnetic Resonance ImagingMRI Scoring System (HEMRIS). Methods: Following a preliminary selection of potential examples of each grade, as per HEMRIS definitions, the images along with detailed definitions and reader rules were discussed at web-based, interactive meetings between the members of the OMERACT MRI in Arthritis Working Group. Results: Reference images of each grade of the MRI features to be assessed using HEMRIS, along with reader rules and recommended MRI sequences are depicted. Conclusion: The presented reference images can be used to guide scoring Achilles tendon and plantar fascia (plantar aponeurosis) enthesitis according to the OMERACT HEMRIS in clinical trials and cohorts in which MRI enthesitis is used as an outcome

    Ultrasound Evaluation of Fluid in Knee Recesses at Varying Degrees of Flexion

    Get PDF
    Various methods are utilized in daily practice to obtain optimal information on effusion in the knee. Our aim is to investigate which scanning position provides the best information about synovial fluid in the knee by using ultrasound and to evaluate the magnitude of difference for measuring synovial fluid in 3 major recesses (suprapatellar, medial parapatellar, and lateral parapatellar) of the knee according to various degrees of flexion. Sonographers in 14 European centers documented bilateral knee joint ultrasound examinations on a total of 148 knee joints. The largest sagittal diameter of fluid was measured in scans corresponding to the 3 major recesses at different (0\ub0, 15\ub0, 30\ub0, 45\ub0, 60\ub0, and 90\ub0) degrees of flexion of the knee. The difference of measurement of effusion according to transducer position, knee position, and the interaction between them was investigated by analysis of variance followed by Tukey's test. No correlation was noted between patient characteristics and ultrasound detection of effusion. The sagittal diameter of synovial fluid in all 3 recesses was greatest at 30\ub0 flexion. Analysis of variance and Tukey's test revealed that the suprapatellar scan and 30\ub0 flexion is the best combination for detecting effusion as confirmed by receiver operator characteristic curve analysis. The suprapatellar scan of the knee in 30\ub0 flexion was the most sensitive position to detect fluid in knee joints. Sagittal diameter of fluid in all 3 recesses increased with the knee in the 30\ub0 flexed position as compared to the extended position. Copyright \ua9 2012 by the American College of Rheumatology

    Atlas for the OMERACT thumb base osteoarthritis MRI scoring system (TOMS)

    Get PDF
    This paper presents an atlas for the Outcome Measures in Rheumatology Clinical Trials (OMERACT) thumb base osteoarthritis MRI scoring system (TOMS). The atlas includes reference images of each grade of each feature that is assessed in TOMS (synovitis grade 0–3, subchondral bone defects grade 0–3, osteophytes grade 0–3, cartilage assessment grade 0–3, subluxation and bone marrow lesions grade 0–3) in the first carpometacarpal and scapho-trapezio-trapezoid joint. The presented reference images can be used to guide scoring of thumb base MRIs in patients with hand osteoarthritis according to the OMERACT TOMS

    A Systematic Literature Review Analysis of Ultrasound Joint Count and Scoring Systems to Assess Synovitis in Rheumatoid Arthritis According to the OMERACT Filter

    Get PDF
    Objective. The OMERACT Ultrasound Task Force is currently developing a global synovitis score (GLOSS) with the objective of feasibly measuring global disease activity in patients with rheumatoid arthritis (RA). In order to determine the minimal number of joints to be included in such a scoring system, and to analyze the metric properties of proposed global (i.e., patient level) ultrasound (US) scoring systems of synovitis in RA, a systematic analysis of the literature was performed. Methods. A systematic literature search of Pubmecl and Embase was performed (January 1, 1984, to March 31, 2010). Original research reports written in English including RA, ultrasound, Doppler, and scoring systems were included. The design, subjects, methods, imaging protocols, and performance characteristics studied were analyzed, as well as the ultrasound definition of synovitis. Results. Of 3004 reports identified, 14 articles were included in the review. We found a lack of clear definition of synovitis as well as varying validity data with respect to the proposed scores. Scoring systems included a wide range and number of joints. All analyzed studies assessed construct validity and responsiveness by using clinical examination, laboratory findings, and other imaging modalities as comparators. Both construct validity and responsiveness varied according to the number and size of joints examined and according to the component of synovitis measured [i.e., gray-scale (GS) or power Doppler (PD) alone or in combination]. With regard to feasibility, time of evaluation varied from 15 to 60 min and increased with the number of joints involved in the examination. Conclusions. Ultrasound can be regarded as a valuable tool for globally examining the extent of synovitis in RA. However, it is presently difficult to determine a minimal number of joints to be included in a global ultrasound score. Further validation of proposed scores is needed. (J Rheumatol 2011; 38:2055-62; doi:10.3899/jrheum.110424
    • …
    corecore