113 research outputs found

    In silico approach for the definition of radiomirnomic signatures for breast cancer differential diagnosis

    Get PDF
    Personalized medicine relies on the integration and consideration of specific characteristics of the patient, such as tumor phenotypic and genotypic profiling. BACKGROUND: Radiogenomics aim to integrate phenotypes from tumor imaging data with genomic data to discover genetic mechanisms underlying tumor development and phenotype. METHODS: We describe a computational approach that correlates phenotype from magnetic resonance imaging (MRI) of breast cancer (BC) lesions with microRNAs (miRNAs), mRNAs, and regulatory networks, developing a radiomiRNomic map. We validated our approach to the relationships between MRI and miRNA expression data derived from BC patients. We obtained 16 radiomic features quantifying the tumor phenotype. We integrated the features with miRNAs regulating a network of pathways specific for a distinct BC subtype. RESULTS: We found six miRNAs correlated with imaging features in Luminal A (miR-1537, -205, -335, -337, -452, and -99a), seven miRNAs (miR-142, -155, -190, -190b, -1910, -3617, and -429) in HER2+, and two miRNAs (miR-135b and -365-2) in Basal subtype. We demonstrate that the combination of correlated miRNAs and imaging features have better classification power of Luminal A versus the different BC subtypes than using miRNAs or imaging alone. CONCLUSION: Our computational approach could be used to identify new radiomiRNomic profiles of multi-omics biomarkers for BC differential diagnosis and prognosis

    A Method for Manufacturing Oncological Phantoms for the Quantification of 18F-FDG PET and DW-MRI Studies

    Get PDF
    The aim of this work was to develop a method to manufacture oncological phantoms for quantitation purposes in 18F-FDG PET and DW-MRI studies. Radioactive and diffusion materials were prepared using a mixture of agarose and sucrose radioactive gels. T2 relaxation and diffusion properties of gels at different sucrose concentrations were evaluated. Realistic oncological lesions were created using 3D-printed plastic molds filled with the gel mixture. Once solidified, gels were extracted from molds and immersed in a low-radioactivity gel simulating normal background tissue. A breast cancer phantom was manufactured using the proposed method as an exploratory feasibility study, including several realistic oncological configurations in terms of both radioactivity and diffusion. The phantom was acquired in PET with 18F-FDG, immediately after solidification, and in DW-MRI the following day. Functional volumes characterizing the simulated BC lesions were segmented from PET and DW-MRI images. Measured radioactive uptake and ADC values were compared with gold standards. Phantom preparation was straightforward, and the time schedule was compatible with both PET and MRI measurements. Lesions appeared on 18F-FDG PET and DW-MRI images as expected, without visible artifacts. Lesion functional parameters revealed the phantom’s potential for validating quantification methods, in particular for new generation hybrid PET-MRI systems

    Impact of Radiometric Variability on Ultra-High Resolution Hyperspectral Imagery Over Aquatic Vegetation: Preliminary Results

    Get PDF
    Over the last two decades, advancements in airborne imaging spectroscopy have prompted the exploitation of lightweight drones for detailed vegetation assessment at unprecedented resolutions. Yet, surface reflectance anisotropy and view-illumination effects may bias spectra extracted from push-broom scanners and derived spectral indices (SIs), particularly over aquatic vegetation, thus impacting the retrieval of biophysical and biochemical vegetation parameters. In this study, the impact of illumination conditions (overcast versus clear sky) and angular configurations (i.e., solar and viewing angles) on radiometric variability of centimetric resolution drone data was empirically investigated over four different aquatic plant species, representing different growth forms and canopy structures. Nadir-normalized reflectance spectra, broadband SIs, and the spectral angle distance to proximal leaf reflectance were used for characterizing and quantifying radiometric variability at canopy and leaf levels. Our findings demonstrated a decrement in reflectance under diffuse light conditions, especially in highly reflective domains within Green (520-580 nm) and Near-Infrared (700-850 nm) ranges, and a marked angular reflectance anisotropy in high absorption spectral regions (i.e., 450-500 nm and 630-700 nm) for aquatic vegetation. The normalized difference vegetation index (NDVI) showed overall lower sensitivity to incoming light variability and angular configurations compared to other tested SIs, whereas the water adjusted vegetation index (WAVI), suitably designed for aquatic vegetation, was less affected by angular anisotropy in floating plants. Indeed, radiometric variability exhibited a dependence on aquatic plant features, i.e., leaf orientation, canopy structure, and affinity with water (as canopy background)

    Prognostic Value of 18 F-Fluorocholine PET Parameters in Metastatic Castrate-Resistant Prostate Cancer Patients Treated with Docetaxel

    Get PDF
    Background and Aim. The availability of new treatments for metastatic castrate-resistant prostate cancer (mCRPC) patients increases the need for reliable biomarkers to help clinicians to choose the better sequence strategy. The aim of the present retrospective and observational work is to investigate the prognostic value of 18 F-fluorocholine ( 18 F-FCH) positron emission tomography (PET) parameters in mCRPC. Materials and Methods. Between March 2013 and August 2016, 29 patients with mCRPC were included. They all received three-weekly docetaxel after androgen deprivation therapy, and they underwent 18 F-FCH PET/computed tomography (CT) before and after the therapy. Semi-quantitative indices such as maximum standardized uptake value (SUV max ), mean standardized uptake value (SUV mean ) with partial volume effect (PVC-SUV) correction, metabolically active tumour volume (MATV), and total lesion activity (TLA) with partial volume effect (PVC-TLA) correction were measured both in pre-treatment and post-treatment 18 F-FCH PET/CT scans for each lesion. Whole-body indices were calculated as sum of values measured for each lesion (SSUV max , SPVC-SUV, SMATV, and STLA). Progression-free survival (PFS) and overall survival (OS) were considered as clinical endpoints. Univariate and multivariate hazard ratios for whole-body 18 F-FCH PET indices were performed, and p<0.05 was considered as significant. Results. Cox regression analysis showed a statistically significant correlation between PFS, SMATV, and STLA. No correlations between OS and 18 F-FCH PET parameters were defined probably due to the small sample size. Conclusions. Semi-quantitative indices such as SMATV and STLA at baseline have a prognostic role in patients treated with docetaxel for mCRPC, suggesting a potential role of 18 F-FCH PET/CT imaging in clinical decision-making

    An Adaptive Thresholding Method for BTV Estimation Incorporating PET Reconstruction Parameters: A Multicenter Study of the Robustness and the Reliability

    Get PDF
    Objective. The aim of this work was to assess robustness and reliability of an adaptive thresholding algorithm for the biological target volume estimation incorporating reconstruction parameters. Method. In a multicenter study, a phantom with spheres of different diameters (6.5–57.4 mm) was filled with 18F-FDG at different target-to-background ratios (TBR: 2.5–70) and scanned for different acquisition periods (2–5 min). Image reconstruction algorithms were used varying number of iterations and postreconstruction transaxial smoothing. Optimal thresholds (TS) for volume estimation were determined as percentage of the maximum intensity in the cross section area of the spheres. Multiple regression techniques were used to identify relevant predictors of TS. Results. The goodness of the model fit was high (R2: 0.74–0.92). TBR was the most significant predictor of TS. For all scanners, except the Gemini scanners, FWHM was an independent predictor of TS. Significant differences were observed between scanners of different models, but not between different scanners of the same model. The shrinkage on cross validation was small and indicative of excellent reliability of model estimation. Conclusions. Incorporation of postreconstruction filtering FWHM in an adaptive thresholding algorithm for the BTV estimation allows obtaining a robust and reliable method to be applied to a variety of different scanners, without scanner-specific individual calibration

    Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound

    Get PDF
    Purpose: Printing technology, capable of producing three‐dimensional (3D) objects, has evolved in recent years and provides potential for developing reproducible and sophisticated physical phantoms. 3D printing technology can help rapidly develop relatively low cost phantoms with appropriate complexities, which are useful in imaging or dosimetry measurements. The need for more realistic phantoms is emerging since imaging systems are now capable of acquiring multimodal and multiparametric data. This review addresses three main questions about the 3D printers currently in use, and their produced materials. The first question investigates whether the resolution of 3D printers is sufficient for existing imaging technologies. The second question explores if the materials of 3D‐printed phantoms can produce realistic images representing various tissues and organs as taken by different imaging modalities such as computer tomography (CT), positron emission tomography (PET), single‐photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), ultrasound (US), and mammography. The emergence of multimodal imaging increases the need for phantoms that can be scanned using different imaging modalities. The third question probes the feasibility and easiness of “printing” radioactive or nonradioactive solutions during the printing process. Methods: A systematic review of medical imaging studies published after January 2013 is performed using strict inclusion criteria. The databases used were Scopus and Web of Knowledge with specific search terms. In total, 139 papers were identified; however, only 50 were classified as relevant for this paper. In this review, following an appropriate introduction and literature research strategy, all 50 articles are presented in detail. A summary of tables and example figures of the most recent advances in 3D printing for the purposes of phantoms across different imaging modalities are provided. Results: All 50 studies printed and scanned phantoms in either CT, PET, SPECT, mammography, MRI, and US—or a combination of those modalities. According to the literature, different parameters were evaluated depending on the imaging modality used. Almost all papers evaluated more than two parameters, with the most common being Hounsfield units, density, attenuation and speed of sound. Conclusions: The development of this field is rapidly evolving and becoming more refined. There is potential to reach the ultimate goal of using 3D phantoms to get feedback on imaging scanners and reconstruction algorithms more regularly. Although the development of imaging phantoms is evident, there are still some limitations to address: One of which is printing accuracy, due to the printer properties. Another limitation is the materials available to print: There are not enough materials to mimic all the tissue properties. For example, one material can mimic one property—such as the density of real tissue—but not any other property, like speed of sound or attenuation

    Targeted radionuclide therapy frontiers in theranostics

    No full text
    corecore