146 research outputs found
GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography
GePEToS is a simulation framework developed over the last few years for
assessing the instrumental performance of future PET scanners. It is based on
Geant4, written in Object-Oriented C++ and runs on Linux platforms. The
validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+
camera. The results of two application examples are presented : the design
optimization of a liquid Xe micro-PET camera dedicated to small animal imaging
as well as the evaluation of the effect of a strong axial magnetic field on the
image resolution of a Concorde P4 micro-PET camera.Comment: 5 pages, 12 figures, submitted to IEEE Transactions on Nuclear
Scienc
Experimental results and first 22Na source image reconstruction by two prototype modules in coincidence of a liquid xenon positron emission tomograph for small animal imaging
International audienceA detector with a very specific design using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Two prototype modules equipped with Position Sensitive Photo Multiplier Tubes (PSPMTs) operating in the VUV range (178 nm) and at 165 K were built and studied in coincidence. This paper reports on energy, time and spatial resolution capabilities of this experimental test bench. Furthermore, these experimental results were used to perform the first image reconstruction of a 22Na source placed in the experimental setup
Experimental study of a liquid Xenon PET prototype module
A detector using liquid Xenon in the scintillation mode is studied for
Positron Emission Tomography (PET). The specific design aims at taking full
advantage of the liquid Xenon properties. It does feature a promising
insensitive to any parallax effect. This work reports on the performances of
the first LXe prototype module, equipped with a position sensitive PMT
operating in the VUV range (178 nm).Comment: Proc. of the 7th International Workshops on Radiation Imaging
Detectors (IWORID-7), Grenoble, France 4-7 July 200
A very low power and low signal 5 bit 50 M samples/s double sampling pipelined ADC for Monolithic Active Pixel Sensors in high energy physics and biomedical imaging applications
International audienc
NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera
A prototype of digital frequency multiplexing electronics allowing the real
time monitoring of microwave kinetic inductance detector (MKIDs) arrays for
mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it
can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires
only two coaxial cables for instrumenting such a large array. The chosen
solution and the performances achieved are presented in this paper.Comment: 21 pages, 14 figure
A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell
A detector using liquid Xenon (LXe) in the scintillation mode is studied for
Positron Emission Tomography (PET) of small animals. Its specific design aims
at taking full advantage of the Liquid Xenon scintillation properties. This
paper reports on energy, time and spatial resolution capabilities of the first
LXe prototype module equipped with a Position Sensitive Photo- Multiplier tube
(PSPMT) operating in the VUV range (178 nm) and at 165 K. The experimental
results show that such a LXe PET configuration might be a promising solution
insensitive to any parallax effect.Comment: 34 pages, 18 pages, to appear in NIM
A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for Monolithic Active Pixel Sensors
soumis à JINSTA 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35µm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1µs. The size for the layout is 80µm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20µm wide
A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for monolithie active pixel sensors
A 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35ÎĽm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1ÎĽs. The size for the layout is 80ÎĽm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20ÎĽm wide
Experimental study of a proximity focusing Cherenkov counter prototype for the AMS experiment
A study prototype of Proximity Focussing Ring Imaging Cherenkov counter has
been built and tested with several radiators using separately cosmic-ray
particles and 12C beam fragmentation products at several energies. Counter
prototype and experimental setup are described, and the results of measurements
reported and compared with simulation results.The performances are discussed in
the perspective of the final counter design.Comment: 27 pages, 16 figures, submitted to NIM
- …