21 research outputs found
Propiedades físicas y químicas de materiales tipo hidroxiapatita sintetizados a partir de residuos de la industria alimentaria mediante el empleo de un método sol-gel modificado
The utilization of industrial wastes is a fundamental part of the circular economy paradigm. The present work shows that solid hydroxyapatite-type materials can be synthesized from food industry residues (i.e. eggshells and mollusk shells) utilizing an experimental methodology based on the modified sol-gel method. For this work, less toxic and less expensive raw materials than those used in classical syntheses have been used. It has also been proposed the use of a natural substance as a porosity generating agent to prepare materials with different physical and chemical properties. Through the use of different analytical techniques, the synthesized materials were characterized. It was confirmed the main phase as hydroxyapatite, in addition to a secondary phase of tricalcium phosphate, calcium carbonate residues of calcium oxide were also identified as residues. Aging temperature and calcination temperature are parameters that other authors have reported influencing the physical and chemical properties of the synthesized materials, in this work it has been confirmed the relationship between the amount of porosity generating agent and the amount of Sol. C also influences the properties of hydroxyapatite-type materials, as an example was determined how is modified the percentage of hydroxyapatite phase.El aprovechamiento de residuos industriales es parte fundamental del paradigma de la economía circular. El presente trabajo muestra que pueden ser sintetizados materiales sólidos tipo hidroxiapatita a partir de residuos de la industria alimentaria (i.e. cascarón de huevo y concha de molusco) empleando una metodología experimental basada en el método sol-gel modificado. Para este trabajo han sido utilizadas materias primas menos tóxicas y menos costosas que las empleadas en las síntesis clásicas. También, se ha propuesto el uso de una sustancia natural como agente generador de porosidad para preparar materiales con distintas propiedades físicas y químicas. Mediante el empleo de distintas técnicas analíticas fueron caracterizados los materiales sintetizados, confirmando que la fase mayoritaria es hidroxiapatita acompañada por una fase secundaria de fosfato tricálcico, además, se identificaron residuos de carbonato de calcio y óxido de calcio, como producto de descomposición del carbonato. La temperatura de envejecimiento y la temperatura de calcinación son parámetros que otros autores han reportado que influyen sobre las propiedades físicas y químicas de los materiales sintetizados, en este trabajo se ha confirmado que la relación entre la cantidad de agente generador de porosidad y la cantidad de sol (Sol. C) influye sobre las propiedades de los materiales sintetizados; por ejemplo, determina como se ve afectado el porcentaje de fase de hidroxiapatita
Síndrome compartimental por extravasación de líquidos en paciente pediátrico, reporte de un caso y revisión de la literatura.: Compartment syndrome due to liquid extravasation in a pediatric patient. Case report and bibliographic review
Extravasation Compartment Syndrome (SCE) is an infrequent pathology, with an incidence of 0,01-6,5%, whom 1,8-11% are children. Communication in children is usually difficult, with high risk of development of SCE. A case about a 9 month old male patient with an over-infected viral pneumonia and a triggered SCE is presented. He received compartmental decompression of right forearm and right hand; however he presented mild sequelae. Treatment of extravasation injury is not always sufficient enough. Mild-to-moderate complications or SCE can be presented. Recognizing clinical manifestations and risk factors and the use of auxiliary studies is fundamental for a good diagnosis and as prevention in children. Faciotomies, gold standard for treatment, are not completely safe, and have an impact on morbidity. Early protocols against extravasation, early examination by surgeon and investigation about SCE in chil-dren are recommended.El Síndrome Compartimental por Extravasación (SCE) es una patología poco frecuente, con una incidencia de 0,01-6,5%, 1.8-11% en niños. En niños pequeños la comunicación es difícil y aumenta el riego de desarrollo de SCE. Se presenta un caso de un masculino de 9 meses de edad, con Neumonía viral sobreinfectada que desencadena SCE; recibió descompresión compartimental del antebrazo y mano derecha; con desarrollo de secuelas leves. Aplicar tratamiento para lesión por extravasación no siempre es suficiente; existen complicaciones leves-moderadas o SCE. Reconocer manifestaciones clínicas y factores de riesgo es fundamental para el diagnóstico, con estudios auxiliares como precaución en niños. La faciotomía, tratamiento estándar de oro; no es inocua e impacta en la morbilidad. Se recomiendan protocolos oportunos para extravasación, valoración temprana por cirujano, investigaciones en pediatría
Human chorionic gonadotropin a tool in the transfer of frozen embryos in double-purpose cows used as recipients
The aim of this study was to evaluate the use of human chorionic gonadotropin at the time applied is performed embryo transfer (day 7) on pregnancy rate in embryo recipient cows in dual purpose cattle, as recipients are used F1 cows (Holstein x Zebu and Zebu x Creole), totaling 300 cows cycling, regardless of the number of births. To synchronize, we used an ear implant containing 3 mg of progestogen norgestomet for 9 days, plus an intramuscular injection (IM) of 3 mg of norgestomet and 5 mg estradiol valerate. At implant removal, was applied 400 IU of equine chorionic gonadotropin (eCG) in both groups. The cows that showed oestrus, were transferred on day 7 of having submitted, only the cows were transferred to a rectal palpation had a corpus luteum of quality 2 and 3, using frozen embryos. The study was divided into two groups: group 1 (control with 70 cows) and group 2, treated with 1500 IU of eCG with 72 cows. Pregnancy diagnosis was performed at 60 days, the embryo transfer. The results were evaluated with a randomized design and statistical analysis, we used a Student t-test to determine the difference between the two groups. The results of this study show a significant difference (P <0.05) in pregnancy rates, demonstrating that treatment with eCG at the embryo transfer increases pregnancy rates in cows transferred. Concluding that eCG treatment (1500 IU) resulted in higher pregnancy rate for the group treated 37 pregnant cows (51.3%) vs. the control group 29 cows pregnant (41.4%) (P <0.05)
Cociente plaquetas/bazo para el diagnóstico de várices esofágicas y riesgo de sangrado en pacientes con insuficiencia hepática: Platelet / spleen ratio for the diagnosis of esophageal varices and the risk of bleeding in patients with liver failure
Introduction: Upper gastrointestinal bleeding of variceal origin has a high mortality. The platelet count/spleen major diameter ratio may be a useful noninvasive parameter to predict esophageal variceal bleeding in cirrhotic patients. Objective: to determine the sensitivity and specificity of the platelet count/spleen diameter ratio for the diagnosis of esophageal varices with risk of bleeding in patients with hepatic insufficiency. Material and Methods: Process study, performed in a Second Level Medical Facility, in patients with liver failure who underwent ultrasound, blood cytometry, liver function tests and endoscopy. Sensitivity and specificity of the platelet/spleen ratio were assessed in patients with esophageal variceal and bleeding risk. Results: There were 70 patients: 28 women, 42 men; main cause of liver failure in men was ethylism in 31 patients and hepatitis C virus in 20 women. The spleen-platelet ratio has a sensitivity of 90%, specificity 83%, false positives 16%, false negatives 9%, positive predictive value 94%, negative predictive value 75%, prevalence of 74% and diagnostic accuracy of 88% to diagnose esophageal varices with risk of bleeding. Conclusion: Platelet/spleen ratio is a useful, non-invasive study to diagnose esophageal varices with bleeding risk, in hospitals where endoscopy is not available.Introducción. El sangrado de tubo digestivo alto de origen variceal tiene una mortalidad alta. El cociente número de plaquetas/diámetro mayor del bazo puede ser un parámetro no invasivo útil para predecir el sangrado por várices esofágicas en pacientes cirróticos. Objetivo: Determinar la sensibilidad y especificidad del cociente número de plaquetas/diámetro mayor del bazo, para el diagnóstico de várices esofágicas con riesgo de sangrado en pacientes con insuficiencia hepática. Material Y Métodos: Estudio de proceso, realizado en un hospital de segundo nivel de atención médica, en pacientes con insuficiencia hepática a quienes se les realizó ultrasonido, citometría hemática, pruebas de función hepática y endoscopia. Se valoró sensibilidad y especificidad del cociente plaquetas/bazo para el diagnóstico de várices esofágicas con riesgo de sangrado. Resultados: Fueron 70 pacientes: 28 mujeres, 42 hombres; causa principal de insuficiencia hepática en hombres fue etilismo en 31 pacientes, virus de la hepatitis C en 20 mujeres. El cociente bazo-plaquetas tiene una sensibilidad de 90%, especificidad 83%, falsos positivos 16%, falsos negativos 9%, valor predictivo positivo 94%, valor predictivo negativo 75 %, prevalencia del 74% y una certeza diagnóstica del 88% para diagnosticar várices esofágicas con riesgo de sangrado. Conclusión: El cociente plaquetas/bazo es un estudio útil y no invasivo para diagnosticar várices esofágicas con riesgo de sangrado, en hospitales donde no se cuenta con endoscopía
On 4-connected geometric graphs
Given a set S of n points in the plane, in this paper we give a necessary and sometimes sufficient condition to build a 4-connected non-crossing geometric graph on S.Gobierno de AragónMinisterio de Economía y CompetitividadEuropean Science FoundationMinisterio de Ciencia e Innovació
Utilization of mechanical power and associations with clinical outcomes in brain injured patients: a secondary analysis of the extubation strategies in neuro-intensive care unit patients and associations with outcome (ENIO) trial
Background: There is insufficient evidence to guide ventilatory targets in acute brain injury (ABI). Recent studies have shown associations between mechanical power (MP) and mortality in critical care populations. We aimed to describe MP in ventilated patients with ABI, and evaluate associations between MP and clinical outcomes. Methods: In this preplanned, secondary analysis of a prospective, multi-center, observational cohort study (ENIO, NCT03400904), we included adult patients with ABI (Glasgow Coma Scale ≤ 12 before intubation) who required mechanical ventilation (MV) ≥ 24 h. Using multivariable log binomial regressions, we separately assessed associations between MP on hospital day (HD)1, HD3, HD7 and clinical outcomes: hospital mortality, need for reintubation, tracheostomy placement, and development of acute respiratory distress syndrome (ARDS). Results: We included 1217 patients (mean age 51.2 years [SD 18.1], 66% male, mean body mass index [BMI] 26.3 [SD 5.18]) hospitalized at 62 intensive care units in 18 countries. Hospital mortality was 11% (n = 139), 44% (n = 536) were extubated by HD7 of which 20% (107/536) required reintubation, 28% (n = 340) underwent tracheostomy placement, and 9% (n = 114) developed ARDS. The median MP on HD1, HD3, and HD7 was 11.9 J/min [IQR 9.2-15.1], 13 J/min [IQR 10-17], and 14 J/min [IQR 11-20], respectively. MP was overall higher in patients with ARDS, especially those with higher ARDS severity. After controlling for same-day pressure of arterial oxygen/fraction of inspired oxygen (P/F ratio), BMI, and neurological severity, MP at HD1, HD3, and HD7 was independently associated with hospital mortality, reintubation and tracheostomy placement. The adjusted relative risk (aRR) was greater at higher MP, and strongest for: mortality on HD1 (compared to the HD1 median MP 11.9 J/min, aRR at 17 J/min was 1.22, 95% CI 1.14-1.30) and HD3 (1.38, 95% CI 1.23-1.53), reintubation on HD1 (1.64; 95% CI 1.57-1.72), and tracheostomy on HD7 (1.53; 95%CI 1.18-1.99). MP was associated with the development of moderate-severe ARDS on HD1 (2.07; 95% CI 1.56-2.78) and HD3 (1.76; 95% CI 1.41-2.22). Conclusions: Exposure to high MP during the first week of MV is associated with poor clinical outcomes in ABI, independent of P/F ratio and neurological severity. Potential benefits of optimizing ventilator settings to limit MP warrant further investigation
Sistema automático de incineración de residuos peligrosos biológico-infecciosos generados por hospitales
IM 27 INCINERACION RESIDUOS PELIGROSO
Cierre transcatéter del conducto arterioso permeable con coils de liberación controlada: Resultados inmediatos y seguimiento a mediano plazo
Objetivo: Determinar la frecuencia de éxito y seguridad del cierre percutáneo del conducto arterioso permeable (CAP) con coils de liberación controlada. Método: Cuarenta y un pacientes pediátricos con conducto arterioso permeable (CAP), de un tamaño pequeño a moderado (diámetro mínimo < 4 mm), fueron sometidos a cierre percutáneo con coils de liberación controlada. Los resultados se establecieron mediante estudios angiográficos y ecocardiográficos. La media de edad fue de 2.0 ±1.3 años (rango, 0.6-5.6 años); la media de peso fue de 10.0 ± 3.4 kg (rango, 4.5-18.0 kg). La media del diámetro mínimo del CAP fue de 1.69 ± 0.6 mm (rango, 0.5-4 mm). Resultados: En 39/41 pacientes se logró la implantación del dispositivo (95%). La relación media del coil/CAP fue de 3.41 ±1.1. Inmediatamente posterior a la oclusión con el coil, 18 conductos arteriosos no mostraron flujo residual por angiografía; 18 tenían un cortocircuito residual trivial, 3 leve y 2 leve. No se presentaron complicaciones significativas con el procedimiento. En las primeras 24 horas posteriores a la implantación del coil, el control ecocardiográfico mostró oclusión completa en 35 pacientes. En los 4 pacientes con flujo residual, el seguimiento ecocardiográfico demostró ausencia del cortocircuito 3 meses después en 2 pacientes y 6 meses después en un paciente. En uno, no se ha logrado la oclusión completa a un año. En dos pacientes (5%) se abandonó el procedimiento: en un paciente, por mostrar flujo residual moderado y movimiento del extremo pulmonar del coil, que debió de ser retirado con un catéter lazo y en otro, por migración del coil. Ambos pacientes fueron enviados a cirugía. En un seguimiento medio de 29.5 ± 16.5 meses (rango, 0 a 60 meses) de los 39 pacientes, no se observó flujo residual por ecocardiografía Doppler color, excepto en uno. Conclusión: Nuestros resultados, en concordancia con otros autores, sugieren que la oclusión del conducto arterioso permeable con coils de liberación controlada, es un método seguro, efectivo y de bajo costo. La oclusión con coil deberá ser el procedimiento de elección en pacientes mayores de 6 meses de edad con conductos arteriosos permeables de un tamaño pequeño a moderado (< 4 mm). En la extensión de este procedimiento a recién nacidos y a pacientes con conductos arteriosos más grandes, deberá considerarse otro tipo de dispositivo oclusor