48 research outputs found

    Metabolite-specific echo-planar imaging of hyperpolarized [1-- 13 C]pyruvate at 4.7 T

    Get PDF
    Although hyperpolarization (HP) greatly increases the sensitivity o

    Mineral Composition of Serial Slaughter Holstein Carcasses

    Get PDF
    Carcasses of 115 Holstein steers were divided into lean, bone, internal cavity, hide, and fat tissues for analysis of P, Ca, K, Mg, and S retention. Every 28 days, five steers from each of two treatments, fed Zilmax for 20 days prior to harvest or not fed Zilmax, were harvested. There were no differences due to treatment or days on feed when mineral retention was expressed as g/100 g of protein gain. Expressing mineral retention relative to protein gain reduced variation due to rate of gain and animal size

    Imaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry

    Get PDF
    \textit{In vivo} spin spin relaxation time (T2T_2) heterogeneity of hyperpolarized \textsuperscript{13}C urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized \textsuperscript{13}C signal with a macromolecular relaxation agent revealed that a long-T2T_2 component of the \textsuperscript{13}C urea signal originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent pools of the \textsuperscript{13}C urea to be distinguished via multi-exponential analysis. The T2T_2 response to induced diuresis and antidiuresis was performed with two imaging agents: hyperpolarized \textsuperscript{13}C urea and a control agent hyperpolarized bis-1,1-(hydroxymethyl)-1-\textsuperscript{13}C-cyclopropane-2H8^2\textrm{H}_8. Large T2T_2 increases in the inner-medullar and papilla were observed with the former agent and not the latter during antidiuresis suggesting that T2T_2 relaxometry may be used to monitor the inner-medullary urea transporter (UT)-A1 and UT-A3 mediated urea concentrating process. Two high resolution imaging techniques - multiple echo time averaging and ultra-long echo time sub-2 mm3^3 resolution 3D imaging - were developed to exploit the particularly long relaxation times observed

    The institutions of archaic post-modernity and their organizational and managerial consequences: The case of Portugal

    Get PDF
    The long march of modernization of the Western societies tends to be presented as following a regular sequence: societies and institutions were pre-modern, and then they were modernized, eventually becoming post-modern. Such teleology may provide an incomplete or distorted narrative of societal evolution in many parts of the world, even in the ‘post-modern heartland’ of Western Europe, with Portugal being a case in point. The concept of archaic post-modernity has been developed by a philosopher, José Gil, to show how Portuguese institutions and organizations combine elements of pre-modernity and post-modernity. The notion of an archaic post-modernity is advanced in order to provide an alternative account of the modernization process, which enriches discussion of the varieties of capitalism. Differences in historical experiences create singularities that may be considered in the analysis of culture, management and organization

    Optimal variable flip angle schemes for dynamic acquisition of exchanging hyperpolarized substrates

    No full text
    In metabolic MRI with hyperpolarized contrast agents, the signal levels vary over time due to T1 decay, T2 decay following RF excitations, and metabolic conversion. Efficient usage of the nonrenewable hyperpolarized magnetization requires specialized RF pulse schemes. In this work, we introduce two novel variable flip angle schemes for dynamic hyperpolarized MRI in which the flip angle is varied between excitations and between metabolites. These were optimized to distribute the magnetization relatively evenly throughout the acquisition by accounting for T1 decay, prior RF excitations, and metabolic conversion. Simulation results are presented to confirm the flip angle designs and evaluate the variability of signal dynamics across typical ranges of T1 and metabolic conversion. They were implemented using multiband spectral-spatial RF pulses to independently modulate the flip angle at various chemical shift frequencies. With these schemes we observed increased SNR of [1-(13)C]lactate generated from [1-(13)C]pyruvate, particularly at later time points. This will allow for improved characterization of tissue perfusion and metabolic profiles in dynamic hyperpolarized MRI

    Directly detected (55)Mn MRI: application to phantoms for human hyperpolarized (13)C MRI development.

    No full text
    In this work we demonstrate for the first time directly detected manganese-55 ((55)Mn) magnetic resonance imaging (MRI) using a clinical 3T MRI scanner designed for human hyperpolarized (13)C clinical studies with no additional hardware modifications. Due to the similar frequency of the (55)Mn and (13)C resonances, the use of aqueous permanganate for large, signal-dense, and cost-effective "(13)C" MRI phantoms was investigated, addressing the clear need for new phantoms for these studies. Due to 100% natural abundance, higher intrinsic sensitivity, and favorable relaxation properties, (55)Mn MRI of aqueous permanganate demonstrates dramatically increased sensitivity over typical (13)C phantom MRI, at greatly reduced cost as compared with large (13)C-enriched phantoms. A large sensitivity advantage (22-fold) was demonstrated. A cylindrical phantom (d=8 cm) containing concentrated aqueous sodium permanganate (2.7 M) was scanned rapidly by (55)Mn MRI in a human head coil tuned for (13)C, using a balanced steady state free precession acquisition. The requisite penetration of radiofrequency magnetic fields into concentrated permanganate was investigated by experiments and high frequency electromagnetic simulations, and found to be sufficient for (55)Mn MRI with reasonably sized phantoms. A sub-second slice-selective acquisition yielded mean image signal-to-noise ratio of ~60 at 0.5 cm(3) spatial resolution, distributed with minimum central signal ~40% of the maximum edge signal. We anticipate that permanganate phantoms will be very useful for testing HP (13)C coils and methods designed for human studies

    Simultaneous Multiagent Hyperpolarized <sup>13</sup>C Perfusion Imaging

    No full text
    PURPOSE: To demonstrate simultaneous hyperpolarization and imaging of three (13)C-labeled perfusion MRI contrast agents with dissimilar molecular structures ([(13)C]urea, [(13)C]hydroxymethyl cyclopropane, and [(13)C]t-butanol) and correspondingly variable chemical shifts and physiological characteristics, and to exploit their varying diffusibility for simultaneous measurement of vascular permeability and perfusion in initial preclinical studies. METHODS: Rapid and efficient dynamic multislice imaging was enabled by a novel pulse sequence incorporating balanced steady state free precession excitation and spectral-spatial readout by multiband frequency encoding, designed for the wide, regular spectral separation of these compounds. We exploited the varying bilayer permeability of these tracers to quantify vascular permeability and perfusion parameters simultaneously, using perfusion modeling methods that were investigated in simulations. “Tripolarized” perfusion MRI methods were applied to initial preclinical studies with differential conditions of vascular permeability, in normal mouse tissues and advanced transgenic mouse prostate tumors. RESULTS: Dynamic imaging revealed clear differences among the individual tracer distributions. Computed permeability maps demonstrated differential permeability of brain tissue among the tracers, and tumor perfusion and permeability were both elevated over values expected for normal tissues. CONCLUSION: Tripolarized perfusion MRI provides new molecular imaging measures for specifically monitoring permeability, perfusion, and transport simultaneously in vivo
    corecore