85 research outputs found

    Whole genome sequencing of a Canadian Bovine gammaherpesvirus 4 strain and possible link between the viral infection and respiratory and reproductive clinical manifestations in dairy cattle

    Full text link
    Bovine gammaherpesvirus 4 (BoHV-4) is a herpesvirus widespread in cattle populations, and with no clear disease association. Its genome contains a long unique coding region (LUR) flanked by polyrepetitive DNA and 79 open reading frames (ORFs), with unique 17 ORFs, named Bo1 to Bo17. In 2009, a BoHV-4 strain was isolated (FMV09-1180503: BoHV-4-FMV) from cattle with respiratory disease from Quebec, Canada, and its LUR was sequenced. Despite the overall high similarity, BoHV-4-FMV had the most divergent LUR sequence compared to the two known BoHV-4 reference strain genomes; most of the divergences were in the Bo genes and in the repeat regions. Our phylogenetic analysis based on DNA polymerase and thymidine kinase genes revealed that virus isolate was BoHV-4 gammaherpesvirus and clustered it together with European BoHV-4 strains. Because BoHV-4-FMV was isolated from animals presenting respiratory signs, we have updated the BoHV-4 Canadian cattle seroprevalence data and tried to find out whether there is a link between clinical manifestation and BoHV-4 seropositivity. An indirect immunofluorescence assay (IFA) was performed with nearly 200 randomized sera of dairy cattle from two Canadian provinces, Quebec (n = 100) and Ontario (n = 91). An additional set of sera obtained from Quebec, from the healthy (n = 48) cows or from the animals experiencing respiratory or reproductive problems (n = 75), was also analyzed by IFA. BoHV-4 seroprevalence in Canadian dairy cattle was 7.9% (Quebec: 6% and Ontario: 9.9%). Among animals from the Quebec-based farms, diseased animals showed higher BoHV-4 seropositivity than healthy animals (P < 0.05), with a significant 2.494 odds ratio of being seropositive in sick compared to healthy animals. Although there is no established direct link between BoHV-4 and specific diseases, these seroprevalence data suggest the possible involvement of BoHV-4 in dairy cattle diseases

    Comparison of user groups' perspectives of barriers and facilitators to implementing electronic health records: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Electronic health record (EHR) implementation is currently underway in Canada, as in many other countries. These ambitious projects involve many stakeholders with unique perceptions of the implementation process. EHR users have an important role to play as they must integrate the EHR system into their work environments and use it in their everyday activities. Users hold valuable, first-hand knowledge of what can limit or contribute to the success of EHR implementation projects. A comprehensive synthesis of EHR users' perceptions is key to successful future implementation. This systematic literature review was aimed to synthesize current knowledge of the barriers and facilitators influencing shared EHR implementation among its various users.</p> <p>Methods</p> <p>Covering a period from 1999 to 2009, a literature search was conducted on nine electronic databases. Studies were included if they reported on users' perceived barriers and facilitators to shared EHR implementation, in healthcare settings comparable to Canada. Studies in all languages with an empirical study design were included. Quality and relevance of the studies were assessed. Four EHR user groups were targeted: physicians, other health care professionals, managers, and patients/public. Content analysis was performed independently by two authors using a validated extraction grid with pre-established categorization of barriers and facilitators for each group of EHR users.</p> <p>Results</p> <p>Of a total of 5,695 potentially relevant publications identified, 117 full text publications were obtained after screening titles and abstracts. After review of the full articles, 60 publications, corresponding to 52 studies, met the inclusion criteria. The most frequent adoption factors common to all user groups were design and technical concerns, ease of use, interoperability, privacy and security, costs, productivity, familiarity and ability with EHR, motivation to use EHR, patient and health professional interaction, and lack of time and workload. Each user group also identified factors specific to their professional and individual priorities.</p> <p>Conclusions</p> <p>This systematic review presents innovative research on the barriers and facilitators to EHR implementation. While important similarities between user groups are highlighted, differences between them demonstrate that each user group also has a unique perspective of the implementation process that should be taken into account.</p

    Nationwide monitoring of end-of-life care via the Sentinel Network of General Practitioners in Belgium: the research protocol of the SENTI-MELC study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>End-of-life care has become an issue of great clinical and public health concern. From analyses of official death certificates, we have societal knowledge on how many people die, at what age, where and from what causes. However, we know little about how people are dying. There is a lack of population-based and nationwide data that evaluate and monitor the circumstances of death and the care received in the final months of life. The present study was designed to describe the places of end-of-life care and care transitions, the caregivers involved in patient care and the actual treatments and care provided to dying patients in Belgium. The patient, residence and healthcare characteristics associated with these aspects of end-of-life care provision will also be studied. In this report, the protocol of the study is outlined.</p> <p>Methods/Design</p> <p>We designed a nationwide mortality follow-back study with data collection in 2005 and 2006, via the nationwide Belgian Sentinel Network of General Practitioners (GPs) i.e. an existing epidemiological surveillance system representative of all GPs in Belgium, covering 1.75% of the total Belgian population. All GPs were asked to report weekly, on a standardized registration form, every patient (>1 year) in their practice who had died, and to identify patients who had died "non-suddenly." The last three months of these patients' lives were surveyed retrospectively. Several quality control measures were used to ensure data of high scientific quality.</p> <p>Discussion</p> <p>In 2005 and 2006, respectively 1385 and 1305 deaths were identified of which 66% and 63% died non-suddenly. The first results are expected in 2007. Via this study, we will build a descriptive epidemiological database on end-of-life care provision in Belgium, which might serve as baseline measurement to monitor end-of-life care over time. The study will inform medical practice as well as healthcare authorities in setting up an end-of-life care policy. We publish the protocol here to inform others, in particular countries with analogue GP surveillance networks, on the possibilities of performing end-of-life care research. A preliminary analysis of the possible strengths, weaknesses and opportunities of our research is outlined.</p

    Users' perspectives of barriers and facilitators to implementing EHR in Canada: A study protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In Canada, federal, provincial, and territorial governments are developing an ambitious project to implement an interoperable electronic health record (EHR). Benefits for patients, healthcare professionals, organizations, and the public in general are expected. However, adoption of an interoperable EHR remains an important issue because many previous EHR projects have failed due to the lack of integration into practices and organizations. Furthermore, perceptions of the EHR vary between end-user groups, adding to the complexity of implementing this technology. Our aim is to produce a comprehensive synthesis of actual knowledge on the barriers and facilitators influencing the adoption of an interoperable EHR among its various users and beneficiaries.</p> <p>Methods</p> <p>First, we will conduct a comprehensive review of the scientific literature and other published documentation on the barriers and facilitators to the implementation of the EHR. Standardized literature search and data extraction methods will be used. Studies' quality and relevance to inform decisions on EHR implementation will be assessed. For each group of EHR users identified, barriers and facilitators will be categorized and compiled using narrative synthesis and meta-analytical techniques. The principal factors identified for each group of EHR users will then be validated for its applicability to various Canadian contexts through a two-round Delphi study, involving representatives from each end-user groups. Continuous exchanges with decision makers and periodic knowledge transfer activities are planned to facilitate the dissemination and utilization of research results in policies regarding the implementation of EHR in the Canadian healthcare system.</p> <p>Discussion</p> <p>Given the imminence of an interoperable EHR in Canada, knowledge and evidence are urgently needed to prepare this major shift in our healthcare system and to oversee the factors that could affect its adoption and integration by all its potential users. This synthesis will be the first to systematically summarize the barriers and facilitators to EHR adoption perceived by different groups and to consider the local contexts in order to ensure the applicability of this knowledge to the particular realities of various Canadian jurisdictions. This comprehensive and rigorous strategy could be replicated in other settings.</p

    Heat transfer in a swirling fluidized bed with Geldart type-D particles

    Get PDF
    A relatively new variant in fluidized bed technology, designated as the swirling fluidized bed (SFB), was investigated for its heat transfer characteristics when operating with Geldart type D particles. Unlike conventional fluidized beds, the SFB imparts secondary swirling motion to the bed to enhance lateral mixing. Despite its excellent hydrodynamics, its heat transfer characteristics have not been reported in the published literature. Hence, two different sizes of spherical PVC particles (2.61mm and 3.65mm) with the presence of a center body in the bed have been studied at different velocities of the fluidizing gas. The wall-to-bed heat transfer coefficients were measured by affixing a thin constant foil heater on the bed wall. Thermocouples located at different heights on the foil show a decrease in the wall heat transfer coefficient with bed height. It was seen that only a discrete particle model which accounts for the conduction between the particle and the heat transfer surface and the gas-convective augmentation can adequately represent the mechanism of heat transfer in the swirling fluidized bed

    Development of an amplicon-based sequencing approach in response to the global emergence of mpox

    Get PDF
    The 2022 multicountry mpox outbreak concurrent with the ongoing Coronavirus Disease 2019 (COVID-19) pandemic further highlighted the need for genomic surveillance and rapid pathogen whole-genome sequencing. While metagenomic sequencing approaches have been used to sequence many of the early mpox infections, these methods are resource intensive and require samples with high viral DNA concentrations. Given the atypical clinical presentation of cases associated with the outbreak and uncertainty regarding viral load across both the course of infection and anatomical body sites, there was an urgent need for a more sensitive and broadly applicable sequencing approach. Highly multiplexed amplicon-based sequencing (PrimalSeq) was initially developed for sequencing of Zika virus, and later adapted as the main sequencing approach for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Here, we used PrimalScheme to develop a primer scheme for human monkeypox virus that can be used with many sequencing and bioinformatics pipelines implemented in public health laboratories during the COVID-19 pandemic. We sequenced clinical specimens that tested presumptively positive for human monkeypox virus with amplicon-based and metagenomic sequencing approaches. We found notably higher genome coverage across the virus genome, with minimal amplicon drop-outs, in using the amplicon-based sequencing approach, particularly in higher PCR cycle threshold (Ct) (lower DNA titer) samples. Further testing demonstrated that Ct value correlated with the number of sequencing reads and influenced the percent genome coverage. To maximize genome coverage when resources are limited, we recommend selecting samples with a PCR Ct below 31 Ct and generating 1 million sequencing reads per sample. To support national and international public health genomic surveillance efforts, we sent out primer pool aliquots to 10 laboratories across the United States, United Kingdom, Brazil, and Portugal. These public health laboratories successfully implemented the human monkeypox virus primer scheme in various amplicon sequencing workflows and with different sample types across a range of Ct values. Thus, we show that amplicon-based sequencing can provide a rapidly deployable, cost-effective, and flexible approach to pathogen whole-genome sequencing in response to newly emerging pathogens. Importantly, through the implementation of our primer scheme into existing SARS-CoV-2 workflows and across a range of sample types and sequencing platforms, we further demonstrate the potential of this approach for rapid outbreak response.This publication was made possible by CTSA Grant Number UL1 TR001863 from the National Center for Advancing Translational Science (NCATS), a component of the National Institutes of Health (NIH) awarded to CBFV. INSA was partially funded by the HERA project (Grant/ 2021/PHF/23776) supported by the European Commission through the European Centre for Disease Control (to VB).info:eu-repo/semantics/publishedVersio

    Afri-Can Forum 2

    Full text link

    Charged-particle distributions at low transverse momentum in s=13\sqrt{s} = 13 TeV pppp interactions measured with the ATLAS detector at the LHC

    Get PDF
    corecore