1,607 research outputs found

    Hadron Spectroscopy with COMPASS at CERN

    Full text link
    The aim of the COMPASS hadron programme is to study the light-quark hadron spectrum, and in particular, to search for evidence of hybrids and glueballs. COMPASS is a fixed-target experiment at the CERN SPS and features a two-stage spectrometer with high momentum resolution, large acceptance, particle identification and calorimetry. A short pilot run in 2004 resulted in the observation of a spin-exotic state with JPC=1−+J^{PC} = 1^{-+} consistent with the debated π1(1600)\pi1(1600). In addition, Coulomb production at low momentum transfer data provide a test of Chiral Perturbation Theory. During 2008 and 2009, a world leading data set was collected with hadron beam which is currently being analysed. The large statistics allows for a thorough decomposition of the data into partial waves. The COMPASS hadron data span over a broad range of channels and shed light on several different aspects of QCD.Comment: 4 pages, 5 figure

    Baseball Card Pricing Model: A Demonstration with Well-known Players

    Get PDF
    A simple hedonic pricing model is developed for baseball cards, of the type often used successfully to model prices for artworks. The model is estimated for a dataset of twelve well-known players observed at eight points in time over a span of twenty years. Dummy variables are used to capture various relevant characteristics of the player or card. This model was estimated separately for two different approaches or assumptions about rates of return. Estimates perform extremely well, explaining most differences among baseball card prices for the cards in the sample. Among extrinsic variables that represent specific players and card characteristics that differentiate cards issued during the same season, race had a significant positive effect on price for black players. Batting average and number of World Series appearances had significant positive impacts on price, but surprisingly, rookie cards tended to be worth relatively less than non-rookie cards. Similarly unexpected findings with respect to players\u27 death and elevation to the Hall of Fame may result from trying to estimate too many characteristics simultaneously on a limited dataset. Results suggest famous players\u27 cards generally are extremely attractive investment instruments

    Triple GEM tracking detectors for COMPASS

    Get PDF
    The small area tracker of COMPASS, a high-luminosity fixed target experiment at CERN's SPS, includes a set of 20 large-size (31\times 31\,\cm^2) Gas Electron Multiplier (GEM) detectors. Based on gas amplification in three cascaded GEM foils, these devices permit to obtain high gain and good spatial resolution even at very high particle fluxes. A two-coordinate projective readout yields, for each track, highly correlated signal amplitudes on both projections, allowing to resolve multiple hits in high occupancy regions close to the central deactivated area of 5\,\cm diameter. At the same time the material exposed to the beam is minimized. Splitting the amplification in three cascaded stages permits to achieve a gain of ∌8000\sim 8000, necessary for efficient (>98%>98\%) detection of minimum ionizing particles on both coordinates, already at relatively moderate voltages across individual GEM foils. As a consequence, the probability of a gas discharge to occur when a heavily ionizing particle enters the detector volume, is reduced by more than an order of magnitude at a given gain compared to the initially foreseen double GEM structure. In conjunction with other strategies resulting from extensive R\&D on discharge phenomena, we were able to further reduce both the triggered by heavily ionizing particles entering the detector volume, this helped to drastically reduce both the energy and the probability of such breakdowns. In order to completely exclude permanent damage to the front-end chip by the rare event of a discharge fully propagating to the readout strips, an external electronic protection circuit is used. The operational characteristics of these detectors were examined both in the laboratory and in the beam, where a spatial resolution for minimum ionizing particles of (46\pm 3)\,\mum and a time resolution of \sim 15\,\ns were achieved. For the 2001 run of COMPASS, a total of 14 triple GEM detectors have been installed. First results from the commissioning phase in the high-intensity ÎŒ\mu beam are presented

    A Search for Dark Matter Annihilation with the Whipple 10m Telescope

    Get PDF
    We present observations of the dwarf galaxies Draco and Ursa Minor, the local group galaxies M32 and M33, and the globular cluster M15 conducted with the Whipple 10m gamma-ray telescope to search for the gamma-ray signature of self-annihilating weakly interacting massive particles (WIMPs) which may constitute astrophysical dark matter (DM). We review the motivations for selecting these sources based on their unique astrophysical environments and report the results of the data analysis which produced upper limits on excess rate of gamma rays for each source. We consider models for the DM distribution in each source based on the available observational constraints and discuss possible scenarios for the enhancement of the gamma-ray luminosity. Limits on the thermally averaged product of the total self-annihilation cross section and velocity of the WIMP, , are derived using conservative estimates for the magnitude of the astrophysical contribution to the gamma-ray flux. Although these limits do not constrain predictions from the currently favored theoretical models of supersymmetry (SUSY), future observations with VERITAS will probe a larger region of the WIMP parameter phase space, and WIMP particle mass (m_\chi).Comment: 33 pages, 12 figures, accepted for publication in the Astrophysical Journa

    Multiwavelength Observations of 1ES 1959+650, One Year After the Strong Outburst of 2002

    Get PDF
    In April-May 2003, the blazar 1ES 1959+650 showed an increased level of X-ray activity. This prompted a multiwavelength observation campaign with the Whipple 10 m gamma-ray telescope, the Rossi X-ray Timing Explorer, the Bordeaux Optical Observatory, and the University of Michigan Radio Astrophysical Observatory. We present the multiwavelength data taken from May 2, 2003 to June 7, 2003 and compare the source characteristics with those measured during observations taken during the years 2000 and 2002. The X-ray observations gave a data set with high signal-to-noise light curves and energy spectra; however, the gamma-ray observations did not reveal a major TeV gamma-ray flare. Furthermore, we find that the radio and optical fluxes do not show statistically significant deviations from those measured during the 2002 flaring periods. While the X-ray flux and X-ray photon index appear correlated during subsequent observations, the apparent correlation evolved significantly between the years 2000, 2002, and 2003. We discuss the implications of this finding for the mechanism that causes the flaring activity.Comment: 17 pages, 6 figures, 2 table

    Multiwavelength Observations of Markarian 421 in March 2001: an Unprecedented View on the X-ray/TeV Correlated Variability

    Get PDF
    (Abridged) We present a detailed analysis of week-long simultaneous observations of the blazar Mrk421 at 2-60 keV X-rays (RXTE) and TeV gamma-rays (Whipple and HEGRA) in 2001. The unprecedented quality of this dataset enables us to establish firmly the existence of the correlation between the TeV and X-ray luminosities, and to start unveiling some of its more detailed characteristics, in particular its energy dependence, and time variability. The source shows strong, highly correlated variations in X-ray and gamma-ray. No evidence of X-ray/gamma-ray interband lag is found on the full week dataset (<3 ks). However, a detailed analysis of the March 19 flare reveals that data are not consistent with the peak of the outburst in the 2-4 keV X-ray and TeV band being simultaneous. We estimate a 2.1+/-0.7 ks TeV lag. The amplitudes of the X-ray and gamma-ray variations are also highly correlated, and the TeV luminosity increases more than linearly w.r.t. the X-ray one. The strong correlation supports the standard model in which a unique electrons population produces the X-rays by synchrotron radiation and the gamma-ray component by inverse Compton scattering. However, for the individual best observed flares the gamma-ray flux scales approximately quadratically w.r.t. the X-ray flux, posing a serious challenge to emission models for TeV blazars. Rather special conditions and/or fine tuning of the temporal evolution of the physical parameters of the emission region are required in order to reproduce the quadratic correlation.Comment: Correction to authorship. Minor editorial changes to text, figures, references. 22 pages (emulateapj), 12 figures (47 postscript files) Published in ApJ, 2008 April 20 (ADS: 2008ApJ...677..906F

    Paclitaxel-Eluting Coronary Stents in Patients With Diabetes Mellitus Pooled Analysis From 5 Randomized Trials

    Get PDF
    ObjectivesWe sought to examine the safety and efficacy of paclitaxel-eluting stents (PES) in patients with diabetes mellitus (DM).BackgroundCompared with patients without DM, patients with DM undergoing percutaneous coronary intervention are at increased risk for mortality and restenosis. The safety of drug-eluting stents in diabetic patients has recently been called into question by a published meta-analysis of randomized trials.MethodsPatient-level data were pooled from 5 prospective, double-blind, randomized trials of PES versus bare-metal stents (BMS) (n = 3,513). Safety and efficacy outcomes through 4 years of follow-up were assessed among the 827 randomized patients (23.6%) with DM.ResultsPatients treated with PES and BMS has similar baseline characteristics among both the diabetic and nondiabetic cohorts within these trials. At 4-year follow-up, there were no significant differences between PES and BMS among diabetic patients in the rates of death (8.4% vs. 10.3%, respectively, p = 0.61), myocardial infarction (6.9% vs. 8.9%, p = 0.17), or stent thrombosis (1.4% vs. 1.2%, p = 0.92). Treatment of diabetic patients with PES compared with treatment with BMS was associated with a significant and durable reduction in target lesion revascularization over the 4-year follow-up period (12.4% vs. 24.7%, p < 0.0001). The relative safety and efficacy of PES compared with the relative safety and efficacy of BMS in diabetic patients extended to both those requiring and not requiring insulin.ConclusionsIn these 5 randomized trials in which patients with single, primarily noncomplex lesions were enrolled, treatment with PES compared with treatment with BMS was safe and effective, resulting in markedly lower rates of target lesion revascularization at 4 years, with similar rates of death, myocardial infarction, and stent thrombosis
    • 

    corecore