16 research outputs found

    Availability of Supervised Exercise Programs and the Role of Structured Home-based Exercise in Peripheral Arterial Disease

    Get PDF
    AbstractObjectivesThe effectiveness of supervised exercise programs (SEPs) for the management of peripheral arterial disease (PAD) can be hampered by low accessibility and poor compliance. The current international availability and use of SEPs was evaluated and the evidence on alternative approaches such as structured, home-based exercise programs (HEPs) was reviewed.Methods-materialsInternational survey on SEP availability among vascular surgeons using an online questionnaire. A systematic review on structured-HEPs effectiveness was also performed.ResultsA total of 378 responses were collected from 43 countries, with the majority (95%) from Europe. Only 30.4% of the participants had access to SEPs and within this group there was significant heterogeneity on the way SEPs were implemented. This systematic review identified 12 studies on the effectiveness of HEPs. In 3 studies SEPs were superior to HEPs in improving functional capacity or equivalent in improving quality of life (QoL). HEPs significantly improved most of the functional capacity and QoL markers when compared to the “go home and walk” advice and baseline measurements.ConclusionsSEPs remain an underutilized tool despite recommendations. Structured HEPs may be effective and can be useful alternatives when SEPs are not available. Further research is warranted to establish cost-effectiveness

    Measurement of Motion of Carotid Bifurcation Plaques

    Get PDF
    Video loops of B-mode ultrasound images of 35 carotid bifurcation plaques were obtained (4 symptomatic and 31 asymptomatic) from patients with carotid bifurcation atherosclerosis. Video loops were classified visually as showing concordant (n=22) or discordant motion (n=13). Concordant plaques were characterized by uniform orientation of motion throughout the cardiac cycle. Discordant plaques exhibited significant spread in motion orientation at different parts of the cardiac cycle, especially at systole. We developed a real-time motion analysis system that applies Farneback's method to estimate velocities between consecutive video frames. For our purposes, we allow a 100msec time interval between the video frames used in the analysis. This approach allows us to analyze significant motions associated with a larger time interval. Over each video frame, we measure the spread of the motion orientation around the dominant orientation. For each video, we look at the spreads of the motion orientations for different motion magnitudes. Using these motion-spread measurements, we can quantify discordant movement. The sum of maximum fan widths for the median pixel motions 5 to 3 (SMFW5to3) had a median value of 100 degrees and interquartile range (IQR) of (80, 110) degrees for the concordant plaques and 270, (230, 430) for the discordant plaques (P <; 0.001). Thus, we have a new tool to differentiate between concordant and discordant plaques

    A comprehensive targeted next-generation sequencing panel for genetic diagnosis of patients with suspected inherited thrombocytopenia.

    Get PDF
    Background: Inherited thrombocytopenias (ITs) are a heterogeneous group of disorders characterized by low platelet counts and often disproportionate bleeding with over 30 genes currently implicated. Previously the UK-GAPP study using whole exome sequencing (WES) identified a pathogenic variant in 19 of 47 (40%) patients of which 71% had variants in genes known to cause IT. Aims: To employ a targeted next-generation sequencing platform to improve efficiency of diagnostic testing and reduce overall costs. Methods: We have developed an IT-specific gene panel as a pre-screen for patients prior to WES using the Agilent SureSelectQXT transposon-based enrichment system. Results: Thirty-one patients were analyzed using the panel-based sequencing, of which; 10% (3/31) were identified with a classified pathogenic variant, 16% (5/31) were identified with a likely pathogenic variant, 51% (16/31) were identified with variants of unknown significance, and 23% (7/31) were identified with either no variant or a benign variant. Discussion and Conclusion: Although requiring further clarification of the impact of the genetic variations, the application of an IT-specific next generation sequencing panel is an viable method of pre-screening patients for variants in known IT-causing genes prior to WES. With an added benefit of distinguishing IT from idiopathic thrombocytopenic purpura (ITP) and the potential to identify variants in genes known to have a predisposition to hematological malignancies, it could become a critical step in improving patient clinical management

    The size of juxtaluminal hypoechoic area in ultrasound images of asymptomatic carotid plaques predicts the occurrence of stroke

    Get PDF
    Objective: To test the hypothesis that the size of a juxtaluminal black (hypoechoic) area (JBA) in ultrasound images of asymptomatic carotid artery plaques predicts future ipsilateral ischemic stroke. Methods: A JBA was defined as an area of pixels with a grayscale value &lt;25 adjacent to the lumen without a visible echogenic cap after image normalization. The size of a JBA was measured in the carotid plaque images of 1121 patients with asymptomatic carotid stenosis 50% to 99% in relation to the bulb (Asymptomatic Carotid Stenosis and Risk of Stroke study); the patients were followed for up to 8 years. Results: The JBA had a linear association with future stroke rate. The area under the receiver-operating characteristic curve was 0.816. Using Kaplan-Meier curves, the mean annual stroke rate was 0.4% in 706 patients with a JBA &lt;4 mm 2, 1.4% in 171 patients with a JBA 4 to 8 mm2, 3.2% in 46 patients with a JBA 8 to 10 mm2, and 5% in 198 patients with a JBA &gt;10 mm2 (P &lt;.001). In a Cox model with ipsilateral ischemic events (amaurosis fugax, transient ischemic attack [TIA], or stroke) as the dependent variable, the JBA (&lt;4 mm2, 4-8 mm2, &gt;8 mm2) was still significant after adjusting for other plaque features known to be associated with increased risk, including stenosis, grayscale median, presence of discrete white areas without acoustic shadowing indicating neovascularization, plaque area, and history of contralateral TIA or stroke. Plaque area and grayscale median were not significant. Using the significant variables (stenosis, discrete white areas without acoustic shadowing, JBA, and history of contralateral TIA or stroke), this model predicted the annual risk of stroke for each patient (range, 0.1%-10.0%). The average annual stroke risk was &lt;1% in 734 patients, 1% to 1.9% in 94 patients, 2% to 3.9% in 134 patients, 4% to 5.9% in 125 patients, and 6% to 10% in 34 patients. Conclusions: The size of a JBA is linearly related to the risk of stroke and can be used in risk stratification models. These findings need to be confirmed in future prospective studies or in the medical arm of randomized controlled studies in the presence of optimal medical therapy. In the meantime, the JBA may be used to select asymptomatic patients at high stroke risk for carotid endarterectomy and spare patients at low risk from an unnecessary operation

    Heteroresistance: A concern of increasing clinical significance?

    No full text
    Recent studies have focused on issues related to heteroresistance, including its definition, methods of detection and frequency. Most such studies have reported data concerning infections caused by Staphylococcus aureus, but the clinical significance of heteroresistance is unclear. Six studies have described infections caused by S. aureus strains that were heteroresistant to vancomycin, with two suggesting an association between the emergence of heteroresistance and treatment failure or mortality, and four suggesting no such association. Further studies are required to evaluate the clinical implications of heteroresistance in an era in which rates of antimicrobial resistance are increasing alarmingly worldwide. © 2007 The Authors Journal Compilation © 2007 European Society of Clinical Microbiology and Infectious Diseases

    No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs

    No full text
    Background Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Methods Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. Results No statistically significant difference was demonstrated between the 2 groups in kinetics (P =.389) or kinematics (P =.275). Conclusion In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. © 2016 Elsevier Inc

    Metastatic Merkel cell carcinoma (MCC) of pancreas and breast: A unique case

    No full text
    Merkel cell carcinoma (MCC) is a rare potentially fatal skin tumor affecting older and immunosuppressed individuals. It is highly malignant with high rates of metastasis and poor survival. We present a case of a 67-year-old woman with a palpable mass in the upper abdomen. An abdominal CT revealed a mass in the tail of the pancreas. Two weeks before, lumpectomy of a 3.5 cm tumor of the left breast had been performed. Histology showed a primary neuroendocrine carcinoma of the mammary gland. The patient&apos;s medical history was significant for a 0.7 × 0.9 cm MCC removed from her left forearm 2.5 years ago. There was no evidence of vascular involvement or peritoneal disease and by all criteria was resectable. A somatostatin receptor scintigraphy showed an enhanced uptake in the pancreatic tail region. The tumor was immunohistochemically strong staining for synaptophysin and CD56. The diagnosis of a metastatic-MCC in the tail of the pancreas was made. Further histological investigation of the prior removed neuroendocrine breast tumor and the MCC of the left forearm confirmed neuroendocrine origin and identical histology to the previously resected MCC of the left forearm. In this article, we aim to highlight that MCC has the potential to spread even in unusual organs, such as pancreas or breast, and therefore a diligent follow-up should be applied in patients with MCC. © 2013 Vernadakis et al.; licensee BioMed Central Ltd

    Response to Letter to the Editor on “No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs.”

    No full text
    Background Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Methods Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. Results No statistically significant difference was demonstrated between the 2 groups in kinetics (P =.389) or kinematics (P =.275). Conclusion In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. © 2016 Elsevier Inc

    Serum biomarkers for the assessment of muscle damage in various surgical approaches in primary total hip arthroplasty: a systematic review of comparative studies

    No full text
    Purpose: Using serum biomarkers, this systematic review assessed soft tissue injury following different total hip arthroplasty surgical approaches. The purposes were to determine if there is any advantage between the standard and minimal invasive approaches, and to compare tissue damage of the respective surgical approaches using biomarkers such as creatine kinase, myoglobin, c-reactive protein, erythrocyte sedimentation rate, skeletal troponin and interleukins. Method: A search in Pubmed/MEDLINE, Scopus and Web of Science databases was conducted in October 2021 with the use of PRISMA guidelines. Search items were (“biomarkers” OR “markers” OR “tissue damage” OR “muscle damage”) AND “approach” AND (“total hip arthroplasty” OR “total hip replacement”). Inclusion criteria were prospective, randomized, controlled trials or prospective, comparative studies, comparing serum markers for muscle damage in two or more surgical approaches for primary total hip arthroplasty. Exclusion criteria were study protocols, case reports, systematic reviews, meta-analyses, studies in non-English language or without available full text, and studies not recording biomarkers of muscle damage. Results: Initial search revealed 508 studies; after subtraction of duplicates, and exclusion criteria, 31 studies remained for analysis. No advantage between different approaches was found when evaluating biomarkers, and no specific biomarkers had a distinct role in tissue damage in total hip arthroplasty. Anterior and minimally invasive approaches were associated with lower values of soft tissue (creatine kinase) and inflammation (c-reactive protein) biomarkers compared to the standard approaches. Conclusion: Measurement of serum biomarkers after primary total hip arthroplasty for the estimation of tissue damage has unclear or little clinical value. Trial registration: PROSPERO Registration: CRD42022303959. © 2022, The Author(s) under exclusive licence to SICOT aisbl
    corecore