193 research outputs found

    Towards an automatic wind speed and direction profiler for Wide Field AO systems

    Get PDF
    Wide Field Adaptive Optics (WFAO) systems are among the most sophisticated AO systems available today on large telescopes. The knowledge of the vertical spatio-temporal distribution of the wind speed (WS) and direction (WD) are fundamental to optimize the performance of such systems. Previous studies already proved that the Gemini Multi-Conjugated AO system (GeMS) is able to retrieve measurements of the WS and WD stratification using the SLODAR technique and to store measurements in the telemetry data. In order to assess the reliability of these estimates and of the SLODAR technique applied to such a kind of complex AO systems, in this study we compared WS and WD retrieved from GeMS with those obtained with the atmospherical model Meso-Nh on a rich statistical sample of nights. It has been previously proved that, the latter technique, provided an excellent agreement with a large sample of radiosoundings both, in statistical terms and on individual flights. It can be considered, therefore, as an independent reference. The excellent agreement between GeMS measurements and the model that we find in this study, proves the robustness of the SLODAR approach. To by-pass the complex procedures necessary to achieve automatic measurements of the wind with GeMS, we propose a simple automatic method to monitor nightly WS and WD using the Meso-Nh model estimates. Such a method can be applied to whatever present or new generation facilities supported by WFAO systems. The interest of this study is, therefore, well beyond the optimization of GeMS performance.Comment: 9 figures, 2 tables, MNRAS accepte

    Laser Velocimeter Measurements in the Leakage Annulus of a Whirling Shrouded Centrifugal Pump

    Get PDF
    Previous experiments conducted in the Rotor Force Test Facility at the California Institute of Technology have thoroughly examined the effect of leakage flows on the rotordynamic forces on a centrifugal pump impeller undergoing a prescribed circular whirl. These leakage flows have been shown to contribute substantially to the total fluid induced forces acting on a pump. However, to date nothing is known of the flow field in the leakage annulus of shrouded centrifugal pumps. No attempt has been made to qualitatively or quantitatively examine the velocity field in the leakage annulus. Hence the test objective of this experiment is to acquire fluid velocity data for a geometry representative of the leakage annulus of a shrouded centrifugal pump while the rotor is whirling using laser velocimetry. Tests are performed over a range of whirl ratios and a flowrate typical of Space Shuttle Turbopump designs. In addition to a qualitive study of the flow field, the velocity data can be used to anchor flow models

    Folding mechanisms steer the amyloid fibril formation propensity of highly homologous proteins

    Get PDF
    Significant advances in the understanding of the molecular determinants of fibrillogenesis can be expected from comparative studies of the aggregation propensities of proteins with highly homologous structures but different folding pathways. Here, we fully characterize, by means of stopped-flow, T-jump, CD and DSC experiments, the unfolding mechanisms of three highly homologous proteins, zinc binding Ros87 and Ml153-149 and zinc-lacking Ml452-151. The results indicate that the three proteins significantly differ in terms of stability and (un)folding mechanisms. Particularly, Ros87 and Ml153-149 appear to be much more stable to guanidine denaturation and are characterized by folding mechanisms including the presence of an intermediate. On the other hand, metal lacking Ml452-151 folds according to a classic two-state model. Successively, we have monitored the capabilities of Ros87, Ml452-151 and Ml153-149 to form amyloid fibrils under native conditions. Particularly, we show, by CD, fluorescence, DLS, TEM and SEM experiments, that after 168 hours, amyloid formation of Ros87 has started, while Ml153-149 has formed only amorphous aggregates and Ml452-151 is still monomeric in solution. This study shows how metal binding can influence protein folding pathways and thereby control conformational accessibility to aggregation-prone states, which in turn changes aggregation kinetics, shedding light on the role of metal ions in the development of protein deposition diseases

    Effects of the solution and first aging treatment applied to as-built and post-HIP CM247 produced via Laser Powder Bed Fusion (LPBF)

    Get PDF
    In this work CM247LC, a low weldable Ni-Based alloy, was produced using selective laser melting (SLM). Despite the initial process parameter optimization, the low defect volume fraction was still uncompliant with manufacturing standards. This condition is principally caused by the high γ’ volume fraction which strongly affects the alloy weldability. Nonetheless, a crack free condition was eventually achieved applying a γ’-sub-solvus Hot Isostatic Pressing Cycle (HIP) which lowered the defects fraction down to 0.04%. The HIP cycle also demonstrated to play an important role in the stabilization of the microstructure, considerably limiting the carbides coarsening during the following heat treatment. Apart from the effectiveness of the healing process brought by HIP, the material microstructure still needs an optimization process which will be described along this paper. In fact, the Initial microstructure obtained after the printing process (the as-built condition) as well as the one obtained after HIP (post-HIP) won’t meet the desired requirements. Namely, the dendritic and γ’ free microstructure of the asbuilt material or the one with coarse and disordered particles obtained right after HIP, still need a tailored homogenization process. This paper will show how the combined effect of the solution and first aging treatment will profoundly alter the γ’ precipitation. More specifically, here, a new heat treatment recipe was developed to promote the precipitation of ordered cuboidal primary γ’ so as to improve creep and high temperature fatigue resistance. Moreover, the use of a γ’ super-solvus temperature allowed to achieve a γ’ volume fraction as high as 73% reducing its average size to 520 nm. At the same time, such heat treatment caused a profound alteration of the crystalline structures of the material promoting a general grain coarsening and the formation of equiaxial grain

    Revised North Star Ambulatory Assessment for Young Boys with Duchenne Muscular Dystrophy

    Get PDF
    The advent of therapeutic approaches for Duchenne muscular dystrophy (DMD) has highlighted the need to identify reliable outcome measures for young boys with DMD. The aim of this study was to develop a revised version of the North Star Ambulatory Assessment (NSAA) suitable for boys between the age of 3 and 5 years by identifying age appropriate items and revising the scoring system accordingly. Using the scale in 171 controls between the age of 2.9 and 4.8 years, we identified items that were appropriate at different age points. An item was defined as age appropriate if it was completed, achieving a full score, by at least 85% of the typically developing boys at that age. At 3 years (±3months) there were only 8 items that were age appropriate, at 3 years and 6 months there were 13 items while by the age of 4 years all 17 items were appropriate. A revised version of the scale was developed with items ordered according to the age when they could be reliably performed. The application of the revised version of the scale to data collected in young DMD boys showed that very few of the DMD boys were able to complete with a full score all the age appropriate items. In conclusion, our study suggests that a revised version of the NSAA can be used in boys from the age of 3 years to obtain information on how young DMD boys acquire new abilities and how this correlates with their peers

    An infusion of new blood using the Toptica laser with GeMS: Results of the commissioning and science performance

    Get PDF
    Adaptive Optics (AO) systems aim at detecting and correcting for optical distortions induced by atmospheric turbulences. The Gemini Multi Conjugated AO System GeMS is operational and regularly used for science observations since 2013 delivering close to diffraction limit resolution over a large field of view. GeMS entered this year into a new era. The laser system has been upgraded from the old 50W Lockheed Martin Coherent Technologies (LMCT) pulsed laser to the Toptica 20/2W CW SodiumStar laser. The laser has been successfully commissioned and is now used regularly in operation. In this paper we first review the performance obtained with the instrument. I will go then into the details of the commissioning of the Toptica laser and show the improvements obtained in term of acquisition, stability, reliability and performanc

    Correction : Long term natural history data in ambulant boys with Duchenne muscular dystrophy : 36-month changes

    Get PDF
    The 6 minute walk test has been recently chosen as the primary outcome measure in international multicenter clinical trials in Duchenne muscular dystrophy ambulant patients. The aim of the study was to assess the spectrum of changes at 3 years in the individual measures, their correlation with steroid treatment, age and 6 minute walk test values at baseline. Ninety-six patients from 11 centers were assessed at baseline and 12, 24 and 36 months after baseline using the 6 minute walk test and the North Star Ambulatory Assessment. Three boys (3%) lost the ability to perform the 6 minute walk test within 12 months, another 13 between 12 and 24 months (14%) and 11 between 24 and 36 months (12%). The 6 minute walk test showed an average overall decline of 1215.8 (SD 77.3) m at 12 months, of 1258.9 (SD 125.7) m at 24 months and 12104.22 (SD 146.2) m at 36 months. The changes were significantly different in the two baseline age groups and according to the baseline 6 minute walk test values (below and above 350 m) (p<0.001). The changes were also significantly different according to steroid treatment (p\u200a=\u200a0.01). Similar findings were found for the North Star Ambulatory Assessment. These are the first 36 month longitudinal data using the 6 minute walk test and North Star Ambulatory Assessment in Duchenne muscular dystrophy. Our findings will help not only to have a better idea of the progression of the disorder but also provide reference data that can be used to compare with the results of the long term extension studies that are becoming available
    • …
    corecore