3,434 research outputs found

    “Education Network” a new way to teach Chemistry

    Get PDF
    The complexity of chemistry has implications for the teaching of chemistry. That chemistry is a very complex subject. The majority of the students at University think that chemistry is a difficult discipline and they have difficulty in understanding the concepts. Moreover, students' interest in chemistry decreases the first year at university. The reason for this decrease might be that the contents of chemistry laboratory classes are boring, out of date and lacking of dynamism that students experience through visual media tools. For these reasons, new programs and methodologies should be developed. Those are based on making chemistry relevant through problem solving and collaborative learning hold promise for reforming chemistry education. It is about an education according to circumstances, which is adapted to context and virtual behaviour of people. It's time to CRUSH boredom by transforming your classroom into an Escape Room adventure. School-based escape games are a great teaching tool. The students while playing, learn. The most important point is that they won’t realize they’re doing both at the same time. In this work, an educational gamification experience based on the escape room concept was developed. The first (Do It Yourself) DIY Escape Room was built the year before at Mechanical Engineer Degree started, that took more than three weeks of work. It was presented to other professors to the same subject at different degrees. That DIY Escape Room was modified and adapted to each group. Each professor changed the clues, problems and so on in order to orientate the topic as much as possible to their students.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    Coordinated thermal and optical observations of Trans-Neptunian object (20000) Varuna from Sierra Nevada

    Get PDF
    We report on coordinated thermal and optical measurements of trans-Neptunian object (20000) Varuna obtained in January-February 2002, respectively from the IRAM 30-m and IAA 1.5 m telescopes. The optical data show a lightcurve with a period of 3.176+/-0.010 hr, a mean V magnitude of 20.37+/-0.08 and a 0.42+/-0.01 magnitude amplitude. They also tentatively indicate that the lightcurve is asymmetric and double-peaked. The thermal observations indicate a 1.12+/-0.41 mJy flux, averaged over the object's rotation. Combining the two datasets, we infer that Varuna has a mean 1060(+180/-220) km diameter and a mean 0.038(+0.022/-0.010) V geometric albedo, in general agreement with an earlier determination using the same technique.Comment: Accepted for publication in Astronomy & Astrophysics (7 pages, including 3 figures

    Water-ice driven activity on Main-Belt Comet P/2010 A2 (LINEAR) ?

    Full text link
    The dust ejecta of Main-Belt Comet P/2010 A2 (LINEAR) have been observed with several telescopes at the at the Observatorio del Roque de los Muchachos on La Palma, Spain. Application of an inverse dust tail Monte Carlo method to the images of the dust ejecta from the object indicates that a sustained, likely water-ice driven, activity over some eight months is the mechanism responsible for the formation of the observed tail. The total amount of dust released is estimated to be 5E7 kg, which represents about 0.3% of the nucleus mass. While the event could have been triggered by a collision, this cannot be decided from the currently available data.Comment: Accepted for ApJ Letter

    Hematuria is associated with more severe acute tubulointerstitial nephritis

    Get PDF
    Acute tubulointerstitial nephritis (ATIN) is a common cause of acute kidney injury. Although haematuria is a risk factor for the development of renal disease, no previous study has analyzed the significance of haematuria in ATIN. Retrospective, observational analysis of 110 patients with biopsy-proven ATIN was conducted. Results: Haematuria was present in 66 (60%) ATIN patients. A higher percentage of ATIN patients with haematuria had proteinuria than patients without haematuria (89.4% vs. 59.1%, p = 0.001) with significantly higher levels of proteinuria (median (interquartile range) protein:creatinine ratio 902.70 (513–1492) vs. 341.00 (177–734) mg/g, p <0.001). Moreover, those patients with more haematuria intensity had a higher urinary protein:creatinine ratio (1352.65 (665–2292) vs. 849.60 (562–1155) mg/g, p = 0.02). Those patients with higher proteinuria were more likely to need renal replacement therapy (22.7 vs. 0%, p = 0.03) and to su er relapse (4 vs. 0%, p = 0.03). At the end of follow up, haematuric ATIN patients had higher serum creatinine levels (3.19 2.91 vs. 1.91 1.17 mg/dL, p = 0.007), and a trend towards a higher need for acute dialysis (7 vs. 1%, p = 0.09) and renal replacement therapy (12.1 vs. 2.3%, p = 0.12). Haematuria is common in ATIN and it is associated with worse renal function outcomesSupported by FIS/FEDER PI17/00130 and PI19/00815, Spanish Ministry of Science and Innovation (RYC-2017-22369 and DTS18/00032), Sociedad Española de Nefrología, Fundacion Renal Iñigo Álvarez de Toledo (FRIAT), ISCIII-RETIC REDinREN RD016/0009 Fondos FEDER, Comunidad de Madrid B2017/BMD-3686CIFRA2-CM, ERA-PerMed-JTC2018 (KIDNEY ATTACK AC18/00064 and PERSTIGAN AC18/00071)

    Marginal bone loss around implants placed in maxillary native bone or grafted sinuses: a retrospective cohort study

    Full text link
    Objectives To assess differences in marginal bone loss around implants placed in maxillary pristine bone and implants placed following maxillary sinus augmentation over a period of 3 years after functional loading. Material and methods Two cohorts of subjects (Group 1: Subjects who received sinus augmentation with simultaneous implant placement; Group 2: Subjects who underwent conventional implant placement in posterior maxillary pristine bone) were included in this retrospective study. Radiographic marginal bone loss was measured around one implant per patient on digitized panoramic radiographs that were obtained at the time of prosthesis delivery (baseline) and 12, 24, and 36 months later. The influence of age, gender, smoking habits, history of periodontal disease, and type of prosthetic connection (internal or external) on marginal bone loss was analyzed in function of the type of osseous support (previously grafted or pristine). Results A total of 105 subjects were included in this study. Cumulative radiographic marginal bone loss ranged from 0 mm to 3.9 mm after 36 months of functional loading. There were statistically significant differences in marginal bone loss between implants placed in grafted and pristine bone at the 12‐month assessment, but not in the subsequent progression rate. External prosthetic connection, smoking, and history of periodontitis negatively influenced peri‐implant bone maintenance, regardless of the type of osseous substrate. Conclusions Implants placed in sites that received maxillary sinus augmentation exhibited more marginal bone loss than implants placed in pristine bone, although marginal bone loss mainly occurred during the first 12 months after functional loading. Implants with external implant connection were strongly associated with increased marginal bone loss overtime.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/102685/1/clr12122.pd

    Tamaño de planta y formación específica en el mercado laboral colombiano

    Get PDF
    Con base en la Encuesta de Calidad de Vida (ECV) de 2003 del DANE, en este trabajo se estudia la formación para el empleo (FPE) en el mercado laboral colombiano. Se encuentra una relación estrecha entre modernidad empresarial y FPE. Utilizando funciones mincerianas modificadas se encuentra que la rentabilidad de la FPE aumenta con el nivel de educación formal y el tamaño de las empresas

    A beam-beam monitoring detector for the MPD experiment at NICA

    Full text link
    The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evolution of the early Universe and the formation of neutron stars. In order to extend the MPD trigger capabilities, we propose to include a high granularity beam-beam monitoring detector (BE-BE) to provide a level-0 trigger signal with an expected time resolution of 30 ps. This new detector will improve the determination of the reaction plane by the MPD experiment, a key measurement for flow studies that provides physics insight into the early stages of the reaction. In this work, we use simulated Au+Au collisions at NICA energies to show the potential of such a detector to determine the event plane resolution, providing further redundancy to the detectors originally considered for this purpose namely, the Fast Forward Detector (FFD) and the Hadron Calorimeter (HCAL). We also show our results for the time resolution studies of two prototype cells carried out at the T10 beam line at the CERN PS complex.Comment: 16 pages, 12 figures. Updated to published version with added comments and correction

    An asymmetric BODIPY triad with panchromatic absorption for high-performance red-edge laser emission

    Get PDF
    © The Royal Society of Chemistry 2015. A rational design of an unprecedented asymmetric cassette triad based entirely on BODIPY chromophores allows efficient light harvesting over the UV-vis spectral region, leading to a bright and stable red-edge laser emission via efficient energy-transfer processes.Peer Reviewe
    corecore