168 research outputs found
Characterization of Spatial Coherence of Synchrotron Radiation with Non-Redundant Arrays of Apertures
We present a method to characterize the spatial coherence of soft X-ray
radiation from a single diffraction pattern. The technique is based on
scattering from non-redundant arrays (NRA) of slits and records the degree of
spatial coherence at several relative separations from one to 15 microns,
simultaneously. Using NRAs we measured the transverse coherence of the X-ray
beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring as
a function of different beam parameters. To verify the results obtained with
the NRAs additional Young's double pinhole experiments were conducted and show
good agreement.Comment: 15 pages, 6 figures, 2 tables, 42 reference
Enhanced Magneto-Optical Edge Excitation in Nanoscale Magnetic Disks
We report unexpected enhancements of the magneto-optical effect in ferromagnetic Permalloy disks of diameter D < 400 nm. The effect becomes increasingly pronounced for smaller D, reaching more than a 100% enhancement for D ¼ 100 nm samples. By means of experiments and simulations, the origin of this effect is identified as a nanoscale ring-shaped region at the disk edges, in which the magneto-optically induced electric polarization is enhanced. This leads to a modification of the electromagnetic near fields and causes the enhanced magneto-optical excitation, independent from any optical resonance.We acknowledge funding from the Basque Government
(Program No. PI2012-47) and the Spanish Government
(Project No.MAT2012-36844).Work at the Universidad de
Cantabria has been supported by MICINN under Project
No. FIS2013-45854-P
A new resorbable device for ligation of blood vessels - A pilot study
<p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p
Direct 2D spatial coherence determination using the Fourier analysis method Multi parameter characterization of the P04 beamline at PETRA III
We present a systematic 2D spatial-coherence analysis of the soft-X-ray beamline P04 at PETRA III for various beamline configurations. The influence of two different beam-defining apertures on the spatial coherence properties of the beam is discussed and optimal conditions for coherence-based experiments are found. A significant degradation of the spatial coherence in the vertical direction has been measured and sources of this degradation are identified and discussed. The Fourier-analysis method, which gives fast and simple access to the 2D spatial coherence function of the X-ray beam, is used for the experiment. Here, we exploit the charge scattering of a disordered nanodot sample allowing the use of arbitrary X-ray photon energies with this method
Prospective study on the mismatch concept in acute stroke patients within the first 24 h after symptom onset - 1000Plus study
<p>Abstract</p> <p>Background</p> <p>The mismatch between diffusion weighted imaging (DWI) lesion and perfusion imaging (PI) deficit volumes has been used as a surrogate of ischemic penumbra. This pathophysiology-orientated patient selection criterion for acute stroke treatment may have the potential to replace a fixed time window. Two recent trials - DEFUSE and EPITHET - investigated the mismatch concept in a multicenter prospective approach. Both studies randomized highly selected patients (n = 74/n = 100) and therefore confirmation in a large consecutive cohort is desirable. We here present a single-center approach with a 3T MR tomograph next door to the stroke unit, serving as a bridge from the ER to the stroke unit to screen all TIA and stroke patients. Our primary hypothesis is that the prognostic value of the mismatch concept is depending on the vessel status. Primary endpoint of the study is infarct growth determined by imaging, secondary endpoints are neurological deficit on day 5-7 and functional outcome after 3 months.</p> <p>Methods and design</p> <p>1000Plus is a prospective, single centre observational study with 1200 patients to be recruited. All patients admitted to the ER with the clinical diagnosis of an acute cerebrovascular event within 24 hours after symptom onset are screened. Examinations are performed on day 1, 2 and 5-7 with neurological examination including National Institute of Health Stroke Scale (NIHSS) scoring and stroke MRI including T2*, DWI, TOF-MRA, FLAIR and PI. PI is conducted as dynamic susceptibility-enhanced contrast imaging with a fixed dosage of 5 ml 1 M Gadobutrol. For post-processing of PI, mean transit time (MTT) parametric images are determined by deconvolution of the arterial input function (AIF) which is automatically identified. Lesion volumes and mismatch are measured and calculated by using the perfusion mismatch analyzer (PMA) software from ASIST-Japan. Primary endpoint is the change of infarct size between baseline examination and day 5-7 follow up.</p> <p>Discussions</p> <p>The aim of this study is to describe the incidence of mismatch and the predictive value of PI for final lesion size and functional outcome depending on delay of imaging and vascular recanalization. It is crucial to standardize PI for future randomized clinical trials as for individual therapeutic decisions and we expect to contribute to this challenging task.</p> <p>Trial Registration</p> <p>clinicaltrials.gov NCT00715533</p
Abridged version of the AWMF guideline for the medical clinical diagnostics of indoor mould exposure
- …