54 research outputs found

    3D Ray Tracing for device-independent fingerprint-based positioning in WLANs

    Get PDF
    We study the use of 3D Ray Tracing (RT) to construct radiomaps for WLAN Received Signal Strength (RSS) fingerprint-based positioning, in conjunction with calibration techniques to make the overall process device-independent. RSS data collection might be a tedious and time-consuming process and also the measured radiomap accuracy and applicability is subject to potential changes in the wireless environment. Therefore, RT becomes a more attractive and efficient way to generate radiomaps. Moreover, traditional fingerprint-based methods lead to radiomaps which are restricted to the device used to generate the radiomap and fail to provide acceptable performance when different devices are considered. We address both challenges by exploiting 3D RT-generated radiomaps and using linear data transformation to match the characteristics of various devices. We evaluate the efficiency of this approach in terms of the time spent to create the radiomap, the amount of data required to calibrate the radiomap for different devices and the positioning error which is compared against the case of using dedicated radiomaps collected with each device

    A randomized controlled trial of exercise in spinal and bulbar muscular atrophy.

    Get PDF
    OBJECTIVE: To determine the safety and efficacy of a home-based functional exercise program in spinal and bulbar muscular atrophy (SBMA). METHODS: Subjects were randomly assigned to participate in 12 weeks of either functional exercises (intervention) or a stretching program (control) at the National Institutes of Health in Bethesda, MD. A total of 54 subjects enrolled, and 50 completed the study with 24 in the functional exercise group and 26 in the stretching control group. The primary outcome measure was the Adult Myopathy Assessment Tool (AMAT) total score, and secondary measures included total activity by accelerometry, muscle strength, balance, timed up and go, sit-to-stand test, health-related quality of life, creatine kinase, and insulin-like growth factor-1. RESULTS: Functional exercise was well tolerated but did not lead to significant group differences in the primary outcome measure or any of the secondary measures. The functional exercise did not produce significantly more adverse events than stretching, and was not perceived to be difficult. To determine whether a subset of the subjects may have benefited, we divided them into high and low functioning based on baseline AMAT scores and performed a post hoc subgroup analysis. Low-functioning individuals receiving the intervention increased AMAT functional subscale scores compared to the control group. INTERPRETATION: Although these trial results indicate that functional exercise had no significant effect on total AMAT scores or on mobility, strength, balance, and quality of life, post hoc findings indicate that low-functioning men with SBMA may respond better to functional exercises, and this warrants further investigation with appropriate exercise intensity

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF
    The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e+ee^+e^- collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years

    Magnetic field sensor based on the domain wall nucleation and propagation

    No full text

    Cordless position sensor based on the magnetostrictive delay line principle

    No full text

    An examination of the appropriateness of the contemporary strategic management models for the Greek small manufacturing enterprises

    No full text
    SIGLEAvailable from British Library Document Supply Centre- DSC:DXN002960 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
    corecore